The effect of temperature on exhaled breath condensate collection

被引:17
|
作者
Vyas, Aditya [1 ,2 ]
Zhang, Qi [1 ,2 ]
Gunaratne, Shyamini [1 ,2 ]
Lee, Wei [1 ,2 ]
Lin, Jiun-Lih [1 ,2 ]
Lin, Jiun-Shiang [2 ]
Warwick, Geoffrey [3 ]
Thomas, Paul S. [1 ,2 ]
机构
[1] Univ New S Wales, Fac Med, Inflammat & Infect Res Ctr, Sydney, NSW, Australia
[2] Prince Wales Hosp, Dept Resp Med, Randwick, NSW 2031, Australia
[3] St Vincents Hosp, Darlinghurst, NSW 2010, Australia
关键词
LEUKOTRIENE B-4; EICOSANOIDS; PROTEIN; LIQUID; VOLUME; PH;
D O I
10.1088/1752-7155/6/3/036002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Exhaled breath condensate (EBC) collection is an innovative method of non-invasively sampling the lung, and can detect a variety of volatile and non-volatile biomarkers, but the disadvantage is the small volume of sample collected. It was hypothesized that a collection system at a lower temperature would increase the volume collected, but may alter the relative concentration of the biomarkers of interest. EBC was collected in a cross-over study using a custom-made collection system, cooled using either wet (4 degrees C) or dry ice (-20 degrees C) in randomized order in normal non-smoking volunteers. The volume of the EBC collected per unit time was determined as were conductivity, the concentrations and total amount of protein, hydrogen peroxide, and nitrite/nitrate concentrations. Dry ice was associated with a 79% greater volume of EBC than the wet ice (1387 +/- 612 mu L; 773 +/- 448 mu L respectively, p < 0.0001). Conductivity was influenced by the temperature of collection (18.78 +/- 6.71 mu S cm(-1) for wet ice and 15.32 +/- 6.28 mu S cm(-1) for dry ice, p = 0.02) as was hydrogen peroxide (1.34 +/- 0.88 mu g mL(-1) for wet ice and 0.68 +/- 0.32 mu g mL(-1) for dry ice, p = 0.009) while the concentrations and total values for protein and nitrate/nitrite were not significantly different (p > 0.05). This pilot study suggests that lower collection temperatures facilitate the collection of a larger sample volume. This larger volume is not simply more dilute, with increased water content, nor is there a simple correction factor that can be applied to the EBC biomarkers to correct for the different methods.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Collection devices influence the constituents of exhaled breath condensate
    Liu, J.
    Conrad, D. H.
    Chow, S.
    Tran, V. H.
    Yates, D. H.
    Thomas, P. S.
    EUROPEAN RESPIRATORY JOURNAL, 2007, 30 (04) : 807 - 808
  • [12] Safety of exhaled breath condensate collection in ventilated children
    Müller, W
    Peters, M
    Jaffé, A
    THORAX, 2003, 58 : 69 - 69
  • [13] Methodological aspects of exhaled breath condensate collection and analysis
    Rosias, Philippe
    JOURNAL OF BREATH RESEARCH, 2012, 6 (02)
  • [14] Safety and success of exhaled breath condensate collection in asthma
    Baraldi, E
    Ghiro, L
    Piovan, V
    Carraro, S
    Zacchello, F
    Zanconato, S
    ARCHIVES OF DISEASE IN CHILDHOOD, 2003, 88 (04) : 358 - 360
  • [15] Comparison of two methods for exhaled breath condensate collection
    Soyer, O. U.
    Dizdar, E. A.
    Keskin, O.
    Lilly, C.
    Kalayci, O.
    ALLERGY, 2006, 61 (08) : 1016 - 1018
  • [16] Selective Collection of Exhaled Breath Condensate for Noninvasive Screening of Breath Glucose
    Desai, Aditya
    Tankasala, Divya
    Ng, Gabriel P.
    Thakkar, Pankti
    Hoilett, Orlando S.
    Mather, Kieren J.
    Linnes, Jacqueline C.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2025, 19 (01): : 161 - 164
  • [17] THE INFLUENCE OF TEMPERATURE ON EXHALED BREATH CONDENSATE CONSTITUENTS
    Zhang, Q.
    Vyas, A.
    Gunaratne, S.
    Lee, W.
    Lin, J-S
    Warwick, G.
    Thomas, P. S.
    RESPIROLOGY, 2012, 17 : 62 - 62
  • [18] Temperature changes in exhaled breath condensate collection devices affect observed acetone concentrations
    Loyola, Bryan R.
    Bhushan, Abhinav
    Schivo, Michael
    Kenyon, Nicholas J.
    Davis, Cristina E.
    JOURNAL OF BREATH RESEARCH, 2008, 2 (03)
  • [19] Design and Analysis of Exhaled Breath Condenser System for Rapid Collection of Breath Condensate
    Ilhamsyah, Rizky
    Dimandja, Jean-Marie D.
    Hesketh, Peter J.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (10)
  • [20] Standardization of the collection of exhaled breath condensate and exhaled breath aerosol using a feedback regulated sampling device
    Winters, Brett R.
    Pleil, Joachim D.
    Angrish, Michelle M.
    Stiegel, Matthew A.
    Risby, Terence H.
    Madden, Michael C.
    JOURNAL OF BREATH RESEARCH, 2017, 11 (04)