The effect of temperature on exhaled breath condensate collection

被引:17
|
作者
Vyas, Aditya [1 ,2 ]
Zhang, Qi [1 ,2 ]
Gunaratne, Shyamini [1 ,2 ]
Lee, Wei [1 ,2 ]
Lin, Jiun-Lih [1 ,2 ]
Lin, Jiun-Shiang [2 ]
Warwick, Geoffrey [3 ]
Thomas, Paul S. [1 ,2 ]
机构
[1] Univ New S Wales, Fac Med, Inflammat & Infect Res Ctr, Sydney, NSW, Australia
[2] Prince Wales Hosp, Dept Resp Med, Randwick, NSW 2031, Australia
[3] St Vincents Hosp, Darlinghurst, NSW 2010, Australia
关键词
LEUKOTRIENE B-4; EICOSANOIDS; PROTEIN; LIQUID; VOLUME; PH;
D O I
10.1088/1752-7155/6/3/036002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Exhaled breath condensate (EBC) collection is an innovative method of non-invasively sampling the lung, and can detect a variety of volatile and non-volatile biomarkers, but the disadvantage is the small volume of sample collected. It was hypothesized that a collection system at a lower temperature would increase the volume collected, but may alter the relative concentration of the biomarkers of interest. EBC was collected in a cross-over study using a custom-made collection system, cooled using either wet (4 degrees C) or dry ice (-20 degrees C) in randomized order in normal non-smoking volunteers. The volume of the EBC collected per unit time was determined as were conductivity, the concentrations and total amount of protein, hydrogen peroxide, and nitrite/nitrate concentrations. Dry ice was associated with a 79% greater volume of EBC than the wet ice (1387 +/- 612 mu L; 773 +/- 448 mu L respectively, p < 0.0001). Conductivity was influenced by the temperature of collection (18.78 +/- 6.71 mu S cm(-1) for wet ice and 15.32 +/- 6.28 mu S cm(-1) for dry ice, p = 0.02) as was hydrogen peroxide (1.34 +/- 0.88 mu g mL(-1) for wet ice and 0.68 +/- 0.32 mu g mL(-1) for dry ice, p = 0.009) while the concentrations and total values for protein and nitrate/nitrite were not significantly different (p > 0.05). This pilot study suggests that lower collection temperatures facilitate the collection of a larger sample volume. This larger volume is not simply more dilute, with increased water content, nor is there a simple correction factor that can be applied to the EBC biomarkers to correct for the different methods.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Comment on 'The effect of temperature on exhaled breath condensate collection'
    Effros, Richard M.
    Casaburi, Richard
    Porszasz, Janos
    Morales, Edith M.
    Saraswat, Aditi
    Rehan, Virender
    JOURNAL OF BREATH RESEARCH, 2012, 6 (04)
  • [2] Reply to comment on 'The effect of temperature on exhaled breath condensate collection'
    Thomas, Paul S.
    Zhang, Qi
    JOURNAL OF BREATH RESEARCH, 2012, 6 (04)
  • [3] Effect of varying respiratory pattern on exhaled breath condensate collection
    Tate, S
    McCafferty, J
    Innes, JA
    Greening, AP
    THORAX, 2002, 57
  • [4] Collection of exhaled breath and exhaled breath condensate in veterinary medicine. A review
    Zollinger, E.
    Clauss, M.
    Steinmetz, H. W.
    Hatt, J. -M.
    VETERINARY QUARTERLY, 2006, 28 (03) : 105 - 117
  • [5] Collection and analysis of exhaled breath condensate in humans
    Mutlu, GM
    Garey, KW
    Robbins, RA
    Danziger, LH
    Rubinstein, I
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (05) : 731 - 737
  • [6] Portability and flexibility in exhaled breath condensate collection
    Vaughan, JW
    DISEASE MARKERS IN EXHALED BREATH: BASIC MECHANISMS AND CLINICAL APPLICATIONS, 2002, 346 : 413 - 415
  • [7] A Novel Collection Of Exhaled Breath Condensate.
    Sol, Joseph Alan
    Quindry, John
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 281 - 281
  • [8] An adaptation for exhaled breath condensate collection in rabbits
    Vento, Daniella Alves
    Cassiano Silveira, Ana Paula
    Arcencio, Livia
    Albuquerque, Agnes A. S.
    Bottura, Camila
    Jordao, Alceu, Jr.
    Barbosa Evora, Paulo Roberto
    Rodrigues, Alfredo Jose
    EXPERIMENTAL LUNG RESEARCH, 2016, 42 (05) : 232 - 236
  • [9] Effect of temperature control on the metabolite content in exhaled breath condensate
    Zamuruyev, Konstantin O.
    Borras, Eva
    Pettit, Dayna R.
    Aksenov, Alexander A.
    Simmons, Jason D.
    Weimer, Bart C.
    Schivo, Michael
    Kenyon, Nicholas J.
    Delplanque, Jean-Pierre
    Davis, Cristina E.
    ANALYTICA CHIMICA ACTA, 2018, 1006 : 49 - 60
  • [10] Exhaled breath condensate collection in the mechanically ventilated patient
    Carter, Stewart R.
    Davis, Christopher S.
    Kovacs, Elizabeth J.
    RESPIRATORY MEDICINE, 2012, 106 (05) : 601 - 613