Robust motion correction for respiratory gated PET/CT using weighted averaging

被引:0
|
作者
Thielemans, Kris [1 ]
Gopalakrishnan, Girish [2 ]
Roy, Arunabha [2 ]
Srikrishnan, V [2 ]
Thiruvenkadam, Sheshadri [2 ]
Wollenweber, Scott D. [3 ]
Manjeshwar, Ravindra M. [4 ]
机构
[1] Hammersmith Hosp, Hammersmith Imanet Ltd, GE Healthcare, Du Cane Rd, London W12 0NN, England
[2] GE Global Res, Bangalore, Karnataka, India
[3] GE Healthcare, Waukesha, WI 53188 USA
[4] GE Global Res, Niskayuna, NY 12309 USA
关键词
POSITRON-EMISSION-TOMOGRAPHY; ARTIFACTS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Movement degrades image quality in PET/CT. A common strategy is to gate the PET data, reconstruct the images, register each image to a reference gate, and average the registered images (Reconstruct, Registered, Average or RRA). Previously, we have shown that this technique can provide more quantitatively accurate PET images compared to the ungated case, while using all the data means that RRA images have better counting statistics than single gates. However, in some instances, e. g. large patient motion, low count statistics acquisitions and/or mismatch between PET and CT position, the registration might fail for a particular gate in some region of the image, resulting in artifacts in the final motion corrected image. We have developed techniques to automatically detect such failures for every image voxel based on an analysis of the motion vectors and the image values. We propose to use a weighted average, where the weights are gate and voxel dependent, and are determined based on estimated registration quality. We illustrate this idea using respiratory gated PET data with PET-PET registration using the level-sets non-rigid registration algorithm. We applied this technique to respiratory gated phantom and patient data from GE Discovery PET/CT scanners. The results demonstrate that the method reliably mitigates any image artifacts and is robust to large lesion displacements and low count density PET images.
引用
收藏
页码:2964 / 2967
页数:4
相关论文
共 50 条
  • [21] Respiratory motion artefacts in pet imaging with CT attenuation correction
    Vale, J.
    Costa, D.
    Fonseca, G.
    Patrina, J.
    Faria, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S272 - S272
  • [22] PET/CT-guided biopsy with respiratory motion correction
    Zhang, Ruoqiao
    Zukic, Dzenan
    Byrd, Darrin W.
    Enquobahrie, Andinet
    Alessio, Adam M.
    Cleary, Kevin
    Banovac, Filip
    Kinahan, Paul E.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2019, 14 (12) : 2187 - 2198
  • [23] PET/CT-guided biopsy with respiratory motion correction
    Ruoqiao Zhang
    Dženan Zukić
    Darrin W. Byrd
    Andinet Enquobahrie
    Adam M. Alessio
    Kevin Cleary
    Filip Banovac
    Paul E. Kinahan
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2019, 14 : 2187 - 2198
  • [24] Respiratory motion artefacts in PET imaging with CT attenuation correction
    Vale, J.
    Costa, D. C.
    Fonseca, G.
    Patrina, J.
    Faria, D.
    Ponte, F.
    Teixeira, J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S355 - S355
  • [25] Use of Thermal Imaging for Respiratory Motion Correction in PET/CT
    Fang, Michael
    Acuffi, Shelley
    Osborne, Dustin
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [26] Respiratory motion correction for PET/CT with internal-external motion correlation
    Liu, Chi
    Alessio, Adam
    Kinahan, Paul
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [27] Lesion detectability in motion compensated image reconstruction of respiratory gated PET/CT
    Thielemans, Kris
    Manjeshwar, Ravindra M.
    Tao, Xiaodong
    Asma, Evren
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3278 - 3282
  • [28] Effect of respiratory motion correction and CT-based attenuation correction on dual-gated cardiac PET image quality and quantification
    Schultz, Jussi
    Siekkinen, Reetta
    Tadi, Mojtaba Jafari
    Teras, Mika
    Klen, Riku
    Lehtonen, Eero
    Saraste, Antti
    Teuho, Jarmo
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (05) : 2423 - 2433
  • [29] Effect of respiratory motion correction and CT-based attenuation correction on dual-gated cardiac PET image quality and quantification
    Jussi Schultz
    Reetta Siekkinen
    Mojtaba Jafari Tadi
    Mika Teräs
    Riku Klén
    Eero Lehtonen
    Antti Saraste
    Jarmo Teuho
    [J]. Journal of Nuclear Cardiology, 2022, 29 : 2423 - 2433
  • [30] A simplified local respiratory motion correction (LRMC) for PET/CT imaging
    Lamare, F.
    Bettinardi, V.
    Visvikis, D.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S145 - S145