Robust motion correction for respiratory gated PET/CT using weighted averaging

被引:0
|
作者
Thielemans, Kris [1 ]
Gopalakrishnan, Girish [2 ]
Roy, Arunabha [2 ]
Srikrishnan, V [2 ]
Thiruvenkadam, Sheshadri [2 ]
Wollenweber, Scott D. [3 ]
Manjeshwar, Ravindra M. [4 ]
机构
[1] Hammersmith Hosp, Hammersmith Imanet Ltd, GE Healthcare, Du Cane Rd, London W12 0NN, England
[2] GE Global Res, Bangalore, Karnataka, India
[3] GE Healthcare, Waukesha, WI 53188 USA
[4] GE Global Res, Niskayuna, NY 12309 USA
关键词
POSITRON-EMISSION-TOMOGRAPHY; ARTIFACTS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Movement degrades image quality in PET/CT. A common strategy is to gate the PET data, reconstruct the images, register each image to a reference gate, and average the registered images (Reconstruct, Registered, Average or RRA). Previously, we have shown that this technique can provide more quantitatively accurate PET images compared to the ungated case, while using all the data means that RRA images have better counting statistics than single gates. However, in some instances, e. g. large patient motion, low count statistics acquisitions and/or mismatch between PET and CT position, the registration might fail for a particular gate in some region of the image, resulting in artifacts in the final motion corrected image. We have developed techniques to automatically detect such failures for every image voxel based on an analysis of the motion vectors and the image values. We propose to use a weighted average, where the weights are gate and voxel dependent, and are determined based on estimated registration quality. We illustrate this idea using respiratory gated PET data with PET-PET registration using the level-sets non-rigid registration algorithm. We applied this technique to respiratory gated phantom and patient data from GE Discovery PET/CT scanners. The results demonstrate that the method reliably mitigates any image artifacts and is robust to large lesion displacements and low count density PET images.
引用
收藏
页码:2964 / 2967
页数:4
相关论文
共 50 条
  • [1] Respiratory motion correction in PET with gated PET/CT data
    Iglesias, J. E.
    Kimiaei, S.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S315 - S315
  • [2] Motion correction of respiratory-gated PET/CT images using polynomial warping
    Woo, Sang-Keun
    Song, Tae Yong
    Choi, Joon Young
    Choi, Yong
    Lee, Kyung-Han
    Kim, Byung-Tae
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2592 - 2594
  • [3] Correction of Respiratory Motion in Dual Gated Cardiac Imaging in PET/CT
    Lamare, F.
    Teras, M.
    Kokki, T.
    Fayad, H.
    Rimoldi, O.
    Camici, P. G.
    Knuuti, J.
    Visvikis, D.
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4530 - +
  • [4] Single-Phase CT Aligned to Gated PET for Respiratory Motion Correction in Cardiac PET/CT
    Wells, R. Glenn
    Ruddy, Terrence D.
    DeKemp, Rob A.
    DaSilva, Jean N.
    Beanlands, Rob S.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (08) : 1182 - 1190
  • [5] Motion Correction for Respiratory Gated PET Images
    Detorie, Nicole
    Dahlbom, Magnus
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3273 - 3277
  • [6] Motion Correction in Respiratory Gated Cardiac PET/CT Using Multi-scale Optical Flow
    Dawood, Mohammad
    Koesters, Thomas
    Fieseler, Michael
    Buether, Florian
    Jiang, Xiaoyi
    Wuebbeling, Frank
    Schaefers, Klaus P.
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT II, PROCEEDINGS, 2008, 5242 : 155 - 162
  • [7] Motion Correction and Attenuation Correction for Respiratory Gated PET Images
    Bai, Wenjia
    Brady, Michael
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (02) : 351 - 365
  • [8] Lung motion correction on respiratory gated 3-D PET/CT images
    Dawood, M
    Lang, N
    Jiang, XY
    Schäfers, KP
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (04) : 476 - 485
  • [9] Evaluation of respiratory and cardiac motion correction schemes in dual gated PET/CT cardiac imaging
    Lamare, F.
    Le Maitre, A.
    Dawood, M.
    Schaefers, K. P.
    Fernandez, P.
    Rimoldi, O. E.
    Visvikis, D.
    [J]. MEDICAL PHYSICS, 2014, 41 (07)
  • [10] Lung Motion Correction of Respiratory Gated 3D PET-CT Images
    Dawood, M.
    Jiang, X.
    Lang, N.
    Schober, O.
    Schaefers, K. P.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S95 - S95