Bending behavior of concrete-encased composite I-girder with corrugated steel web

被引:63
|
作者
He, Jun [1 ,3 ]
Liu, Yuqing [2 ]
Chen, Airong [2 ]
Wang, Dalei [2 ]
Yoda, Teruhiko [3 ]
机构
[1] Changsha Univ Sci & Technol, Sch Civil Engn & Architecture, Changsha, Hunan, Peoples R China
[2] Tongji Univ, Dept Bridge Engn, Shanghai 200092, Peoples R China
[3] Waseda Univ, Dept Civil & Environm Engn, Tokyo, Japan
关键词
Composite girder; Concrete encasement; Corrugated steel web; Flexural loading test; Bending strength; SHEAR BEHAVIOR; BEAMS;
D O I
10.1016/j.tws.2013.08.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A partially encased composite l-girder with flat or corrugated web has been proposed to improve the structural performance of continuous composite girder under hogging moment. The flexural behavior of such structure under two points symmetric loading has been experimentally and analytically investigated. Static flexural loading tests showed that the partially encased girder improved bending strength in comparison to steel I-girder, as local bucking of steel flange was restricted by encased concrete. Especially for the corrugated web girder, the ultimate bending strength was improved about 20%, and the ductility also increased about 3 times. In addition, the limitation of width-to-thickness ratios for steel and concrete-encased composite I-girders with corrugated web were suggested to prevent premature failure due to local buckling of compressive flange. Moreover, the analytical methods of flexural strength under service and ultimate state for partially encased composite girder were proposed and verified with experimental results. It was found that the analytical bending strengths agreed well with the experimental ones at both service and ultimate state, which means the proposed analytical equations can be applied in predicting flexural strength accurately for such encased composite girder with flat or corrugated web. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:70 / 84
页数:15
相关论文
共 50 条
  • [21] Behavior of lightweight aggregate concrete-encased composite columns
    Al-Shahari, AM
    Hunaiti, YM
    Abu Ghazaleh, B
    STEEL AND COMPOSITE STRUCTURES, 2003, 3 (02): : 97 - 110
  • [22] Study on Web Parameters of Prestressed Concrete Composite Box Girder with Corrugated Steel Web
    Yang, Xialin
    Niu, Linmin
    Zhang, Rongling
    Wei, Guoxiang
    ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 1087 - 1091
  • [23] Lateral bracing of I-girder with corrugated webs under uniform bending
    Korrani, Hamid Reza Kazemi Nia
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (12) : 1502 - 1509
  • [24] Experimental Study on Steel-Concrete Composite Twin I-Girder Bridges
    Lin, Weiwei
    Lam, Heang
    Yoda, Teruhiko
    JOURNAL OF BRIDGE ENGINEERING, 2020, 25 (01)
  • [25] Behavior of corrugated steel I-girder webs subjected to patch loading: Parametric study
    Inaam, Qazi
    Upadhyay, Akhil
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 165 (165)
  • [26] Nonlinear analysis of composite beams with concrete-encased steel truss
    Tullini, N.
    Minghini, F.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 91 : 1 - 13
  • [27] Behavior of new hybrid connection between steel beam and concrete-encased composite column
    Derakhshesh, Payman
    Mirghaderi, Seyed Rasoul
    Nouri, Gholamreza
    Farzam, Masood
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 210
  • [28] Comparative strength analyses of concrete-encased steel composite columns
    Mirza, SA
    Lacroix, EA
    JOURNAL OF STRUCTURAL ENGINEERING, 2004, 130 (12) : 1941 - 1953
  • [29] Shear performance of concrete-encased tapered box girders with corrugated steel webs
    Wang, Fei
    Cheng, Yikai
    Zhou, Man
    Lin, Tianfa
    STRUCTURES, 2025, 71
  • [30] Bending Strength of a Horizontally Curved Composite I-Girder Bridge
    Yoo, Chai H.
    Kim, Kyungsik
    Lee, Kyoung C.
    Kang, Junsuk
    JOURNAL OF BRIDGE ENGINEERING, 2013, 18 (05) : 388 - 399