Coaxial Termination Load for High-Voltage Fast Transient Pulse Measurement

被引:5
|
作者
Ryu, Seung-Kab [1 ,2 ]
Kim, Yong-Hoon [2 ]
机构
[1] Elect & Telecommun Res Inst, Attached Inst, Convergence Technol Dept, Taejon 305600, South Korea
[2] Gwangju Inst Sci & Technol, Dept Mechatron, Kwangju 500712, South Korea
关键词
Distributed rod resistor; high-voltage fast transient pulse termination; ultrawideband (UWB) coaxial load; POWER; SUSCEPTIBILITY; POLYETHYLENE; GENERATORS; SYSTEMS;
D O I
10.1109/TPS.2012.2234482
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
A high-voltage fast transient pulse termination load using a 10-mm distributed ceramic-carbon-rod resistor has been developed. It is capable of measuring a pulse's voltage amplitudes up to 100 kV and a rise time less than 300 ps. A difficulty for the development of the high-voltage ultrawideband (UWB) termination device is the compromise of the resistive element size considering opposite characteristics of the high voltage and the wideband frequency. A smaller resistor shows the better high-frequency performance but the worse high-voltage insulation characteristic. Many previous studies in the area of pulsed-power development have used a nonscaled load device for the pulse termination; nevertheless, a mismatch between a source and a load impedance results in significant misunderstanding of the output voltage in a high-voltage fast transient pulse measurement. In this paper, we propose a newly developed high-voltage UWB coaxial load improving impedance characteristics of a nonscaled load device. Physical length of a rod resistor is far longer than a wavelength of an input pulse so that the impedance linearly increases in the moving direction of the incoming pulse. The proposed log-scaled coaxial load device with a distributed ceramic-carbon-rod resistor has a property of compensating impedance variations, which is caused by the usage of an electrically long rod resistor, by means of diminishing coaxial characteristic impedance exponentially along the resistor. This diminishing coaxial structure makes it possible to maintain consistent impedance through the entire load device. Experimental results show good agreement with expectations in aspects of the voltage standing-wave ratio under 1.25 : 1 from dc to 10 GHz; peak impedance variations under 10% with the final converged impedance of 54.86 Omega; and negligible reflections when injecting the repetitive pulsed input with amplitudes from 15 to 100 kV, a rise time below 300 ps, and repetition rates under 10 kHz.
引用
收藏
页码:528 / 539
页数:12
相关论文
共 50 条
  • [21] HIGH-VOLTAGE PULSE ELECTROPHORESIS
    DUKHIN, SS
    MISHCHUK, NA
    RUKOBRATSKII, NI
    COLLOID JOURNAL OF THE USSR, 1988, 50 (01): : 12 - 18
  • [22] HIGH-VOLTAGE PULSE GENERATOR
    KARDASHE.GA
    PERSHIN, AS
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1968, (03): : 618 - &
  • [23] MEASUREMENT OF CHARGE-DISTRIBUTIONS IN COAXIAL STRUCTURES - APPLICATION TO HIGH-VOLTAGE CABLES
    MAHDAVI, S
    ALQUIE, C
    LEWINER, J
    IEEE 1989 ANNUAL REPORT: CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 1989, : 296 - 302
  • [24] HIGH-VOLTAGE PULSE GENERATOR
    BARABASH, LZ
    KRYZHANOVSKII, OI
    LEBEDEV, PI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1970, (01): : 133 - +
  • [25] Development of a fast rise-time, high-voltage pulse generator
    Shanghai Jiaotong University, Shanghai 200030, China
    不详
    Hedianzixue Yu Tance Jishue, 2006, 2 (184-186):
  • [26] Semiconductor switch-based fast high-voltage pulse generators
    Kim, JH
    Jeong, IW
    Ryoo, HJ
    Shenderey, S
    Kim, JS
    Rim, GH
    PPC-2003: 14TH IEEE INTERNATIONAL PULSED POWER CONFERENCE, VOLS 1 AND 2, DIGEST OF TECHNICAL PAPERS, 2003, : 665 - 668
  • [27] FAST SOLID-STATE HIGH-VOLTAGE PULSE-GENERATOR
    CHRISTIANSEN, J
    FRANK, K
    HARTMANN, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 256 (03): : 529 - 531
  • [28] Performances of high-voltage glass insulators subjected to fast transient overvoltages
    Femia, N
    Lupo, G
    Petrarca, C
    Tucci, V
    Vitelli, M
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 1996, 6 (02): : 119 - 124
  • [29] A Modular Unipolar/Bipolar High-Voltage Pulse Generator Suitable for High Resistive Load
    Taherian, Mehdi
    Roshan, Saber
    Allahbakhshi, Mehdi
    Farjah, Ebrahim
    Ghanbari, Teymoor
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2023, 51 (05) : 1279 - 1289
  • [30] On optimization of the insulation of high-voltage coaxial bushing
    Ivanov D.V.
    Ostreiko V.N.
    Yaroshenko D.S.
    Russian Electrical Engineering, 2016, 87 (4) : 228 - 230