A multicentre prospective randomised study of single-incision mini-sling (Ajust®) versus tension-free vaginal tape-obturator (TVT-O™) in the management of female stress urinary incontinence: pain profile and short-term outcomes

被引:45
|
作者
Mostafa, Alyaa [1 ]
Agur, Wael [2 ]
Abdel-All, Mohamed
Guerrero, Karen [3 ]
Lim, Chi
Allam, Mohamed
Yousef, Mohamed [3 ]
N'Dow, James [1 ]
Abdel-Fattah, Mohamed [1 ]
机构
[1] Univ Aberdeen, Aberdeen AB25 2ZD, Scotland
[2] Ayrshire & Arran NHS, Ayr, Scotland
[3] Greater Glasgow Hlth Board, Glasgow, Lanark, Scotland
关键词
Mini-slings; Mid-urethral slings; Tension-free vaginal tape; Stress urinary incontinence; Single-incision tapes; TVT-O; INSIDE-OUT; QUESTIONNAIRE; VALIDATION; METAANALYSIS; SECUR;
D O I
10.1016/j.ejogrb.2012.06.022
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objectives: To compare the postoperative pain profile, pen-operative details, and short-term patient-reported and objective success rates of single-incision mini-slings (SIMS) versus standard mid-urethral slings (SMUS). Study design: In a multicentre prospective randomised trial in six UK centres in the period between October 2009 and October 2010, 137 women were randomised to either adjustable SIMS (Ajust (R), C. R. Bard Inc., NJ, USA), performed under local anaesthesia as an opt-out policy (n = 69), or SMUS (TVT-O (TM), Ethicon Inc., Somerville, USA) performed under general anaesthesia (n = 68). Randomisation was done through number-allocation software and using telephone randomisation. Postoperative pain profile (primary outcome) was assessed on a ten-point visual analogue scale at fixed time-points. Pre- and post operatively (4-6 months) women completed symptom severity, urgency perception scale (UPS), quality of life and sexual function questionnaires. In addition, women completed a Patient Global Impression of Improvement Questionnaire and underwent a cough stress test at 4-6 months follow up. Sample size calculation was performed and data were analysed using SPSS 18. Descriptive analyses are given and between-group comparisons were performed using chi-square, Fischer exact test and Mann-Whitney test as appropriate. Significance level was set at 5%. Results: Women in the SIMS Ajust (R) group had a significantly lower postoperative pain profile up to 4 weeks (p = <0.001, 95% CI 1.151, 2.480). There was no significant difference in pen-operative complications between groups. All 137 women completed the 4-6 months follow-up. Patient-reported and objective cure rates were not significantly different: 85.5% versus 91.2% (p = 0.443) and 90% versus 97% (p = 0.165) between the SIMS Ajust (R) and TVT-O (TM) groups respectively. There was a trend towards higher rates of de novo urgency or worsening of pre-existing urgency in the SIMS Ajust (R) group (21.7% versus 8.8%) but this did not reach statistical significance (p = 0.063). Women in the SIMS Ajust (R) group had shorter hospital stay (median (IQR) 3.65 (2.49, 4.96)) compared to (4.42 (3.16, 5.56)) the TVT-O (TM) group 95% CI (-0.026, 1.326), with significantly earlier return to normal activities (p = 0.025) and to work (p = 0.006). Conclusion: The adjustable single-incision mini-sling (Ajust (R)) is associated with a significantly improved postoperative pain profile and earlier return to work when compared to standard mid-urethral slings (TVT-O (TM)), with encouraging results in patient-reported and objective success rates at short-term follow-up. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:115 / 121
页数:7
相关论文
共 41 条
  • [11] Multicenter Prospective Randomized Study of Single-incision Mini-sling Vs Tension-free Vaginal Tape-obturator in Management of Female Stress Urinary Incontinence: A Minimum of 1-Year Follow-up EDITORIAL COMMENT
    Blok, Bertil F. M.
    [J]. UROLOGY, 2013, 82 (03) : 559 - 559
  • [12] Tension-free vaginal tape obturator versus Ajust adjustable single incision sling procedure in women with urodynamic stress urinary incontinence
    Grigoriadis, C.
    Bakas, P.
    Derpapas, A.
    Creatsa, M.
    Liapis, A.
    [J]. EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2013, 170 (02) : 563 - 566
  • [13] Surgical treatment of stress urinary incontinence using the tension-free vaginal tape-obturator system (TVT-O) technique
    Jakimiuk, Artur J.
    Maciejewski, Tomasz
    Fritz, Anna
    Borucki, Wojciech
    Namirski, Michal
    Szafranko, Krzysztof
    [J]. EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2007, 135 (01) : 127 - 131
  • [14] Single-Incision Mini-Sling Compared With Tension-Free Vaginal Tape for the Treatment of Stress Urinary Incontinence A Randomized Controlled Trial
    Barber, Matthew D.
    Weidner, Alison C.
    Sokol, Andrew I.
    Amundsen, Cindy L.
    Jelovsek, J. Eric
    Karram, Mickey M.
    Ellerkmann, Mark
    Rardin, Charles R.
    Iglesia, Cheryl B.
    Toglia, Marc
    [J]. OBSTETRICS AND GYNECOLOGY, 2012, 119 (02): : 328 - 337
  • [15] Surgeon-tailored polypropylene mesh as a tension-free vaginal tape-obturator versus original TVT-O for the treatment of female stress urinary incontinence: a long-term comparative study
    ElSheemy, Mohammed S.
    Fathy, Hesham
    Hussein, Hussein A.
    Elsergany, Ragheb
    Hussein, Eman A.
    [J]. INTERNATIONAL UROGYNECOLOGY JOURNAL, 2015, 26 (10) : 1533 - 1540
  • [16] Surgeon-tailored polypropylene mesh as a tension-free vaginal tape-obturator versus original TVT-O for the treatment of female stress urinary incontinence: a long-term comparative study
    Mohammed S. ElSheemy
    Hesham Fathy
    Hussein A. Hussein
    Ragheb Elsergany
    Eman A. Hussein
    [J]. International Urogynecology Journal, 2015, 26 : 1533 - 1540
  • [17] Learning Curve for the Tension-Free Vaginal Tape-Obturator Procedure for Female Stress Urinary Incontinence: A Prospective Single-Surgeon Study
    Song, Ruixiang
    He, Xing
    Chang, Yifan
    Zhu, Feng
    Zhang, Wei
    Cheng, Xin
    Song, Qixiang
    Hao, Yiru
    Huang, Mou
    Huang, Guixiao
    Li, Huizhen
    [J]. JOURNAL OF ENDOUROLOGY, 2020, 34 (02) : 209 - 214
  • [18] EFFICIENCY OF TREATMENT FOR FEMALE SUI (STRESS URINARY INCONTINENCE) USING THE TVT-O (R) (TENSION-FREE VAGINAL TAPE OBTURATOR) TECHNIQUE
    Carauleanu, A.
    Socolov, Demetra
    Grigore, Mihaela
    Gabia, Ramona Oana
    Rugina, V.
    Lupascu, Ivona Anghelache
    [J]. MEDICAL-SURGICAL JOURNAL-REVISTA MEDICO-CHIRURGICALA, 2016, 120 (03): : 573 - 580
  • [19] Short-term outcomes of adjustable single-incision sling (Ajust™) procedure for stress urinary incontinence: a prospective single-center study
    Jiang, Tao
    Xia, Zhijun
    Cheng, Dali
    Song, Yue
    Guo, Zhiqiang
    Hu, Qing
    Zhao, Ying
    Yin, Yitong
    [J]. EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2015, 186 : 59 - 62
  • [20] TENSION-FREE VAGINAL TAPE OBTURATOR (TVT-O) FOR THE TREATMENT OF FEMALE URINARY INCONTINENCE - EFFICACY AND PATIENT SATISFACTION IN THE LONG-TERM FOLLOW-UP
    Warro, A.
    Ojala, J.
    Ala-Nissila, S.
    Laurikainen, E.
    [J]. NEUROUROLOGY AND URODYNAMICS, 2019, 38 : S87 - S88