Apparent diffusion coefficients of the five major metabolites measured in the human brain in vivo at 3T

被引:21
|
作者
Deelchand, Dinesh K. [1 ]
Auerbach, Edward J.
Marjanska, Malgorzata
机构
[1] Univ Minnesota, Ctr Magnet Resonance Res, 2021 6th St SE, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
STEAM; PRESS; ADC; glutamate; myo-inositol; MAGNETIC-RESONANCE-SPECTROSCOPY; MR SPECTROSCOPY; NMR-SPECTROSCOPY; RAT-BRAIN; 7; T; WEIGHTED SPECTROSCOPY; WHITE-MATTER; SPIN SYSTEMS; ECHO; SEQUENCE;
D O I
10.1002/mrm.26969
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo measure the apparent diffusion coefficients (ADC) of five main metabolites in the human brain at 3T with PRESS and STEAM, avoiding measurement biases because of cross-terms. Cross-terms arise from interactions between slice-selection and spoiler gradients in the localized spectroscopy sequence and the diffusion gradients. MethodsDiffusion-weighted spectra were acquired from the prefrontal cortex in five healthy subjects using STEAM (echo time [TE]/mixing time [TM]/pulse repetition time [TR]=21.22/105/3000 ms, b-values=0 and 3172 s/mm(2)) and PRESS (TE/TR=54.2/3000 ms, b-values=0 and 2204 s/mm(2)). Diffusion weighting was applied using bipolar gradients in three orthogonal directions. Post-processed spectra were analyzed with LCModel, and the trace/3 ADC values were calculated. ResultsComparable trace/3 ADC values (0.14-0.18 mu m(2)/ms) were obtained for five main metabolites with both methods. These metabolites were quantified with Cramer-Rao lower bounds below 15%. ConclusionThe ADC values of the five main metabolites were successfully measured in the human brain at 3T with eliminated directional dependence. Both STEAM and PRESS can be used to probe the diffusivity of metabolites in normal brain and various pathologies on the clinical scanner with slightly higher precision achieved with STEAM for glutamate and myo-inositol. Magn Reson Med 79:2896-2901, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:2896 / 2901
页数:6
相关论文
共 50 条
  • [31] Comparison of Diffusion Metrics Obtained at 1.5T and 3T in Human Brain With Diffusional Kurtosis Imaging
    Shaw, Calvin B.
    Jensen, Jens H.
    Deardorff, Rachael L.
    Spampinato, Maria Vittoria
    Helpern, Joseph A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (03) : 673 - 680
  • [32] Quantitative characterization of carotid plaque components using MR apparent diffusion coefficients and longitudinal relaxation rates at 3T: A comparison with histology
    Ota, Hideki
    Tamura, Hajime
    Itabashi, Ryo
    Yazawa, Yukako
    Nakamura, Yasuhiro
    Hisamatsu, Kenji
    Takamatsu, Manabu
    Endo, Hidenori
    Niizuma, Kuniyasu
    Enomoto, Yukiko
    Nagasaka, Tatsuo
    Kajita, Kimihiro
    Watanabe, Mika
    Yoshimura, Shinichi
    Yuan, Chun
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (06) : 1657 - 1667
  • [33] Exponential apparent diffusion coefficient in evaluating prostate cancer at 3T: preliminary experience
    Park, Sung Y.
    Kim, Chan K.
    Park, Jung J.
    Park, Byung K.
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1058):
  • [34] Apparent diffusion coefficient reproducibility in brain tumors measured on 1.5 and 3 T clinical scanners: A pilot study
    Merhemic, Zulejha
    Imsirovic, Bilal
    Bilalovic, Nurija
    Stojanov, Dragan
    Boban, Jasmina
    Thurnher, Majda M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 108 : 249 - 253
  • [35] Preoperative histological grading of meningiomas using apparent diffusion coefficient at 3T MRI
    Watanabe, Yosuke
    Yamasaki, Fumiyuki
    Kajiwara, Yoshinori
    Takayasu, Takeshi
    Nosaka, Ryo
    Akiyama, Yuji
    Sugiyama, Kazuhiko
    Kurisu, Kaoru
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (04) : 658 - 663
  • [36] Reproducibility and optimization of in vivo human diffusion-weighted MRS of the corpus callosum at 3T and 7T
    Wood, Emily T.
    Ercan, Ayse Ece
    Branzoli, Francesca
    Webb, Andrew
    Sati, Pascal
    Reich, Daniel S.
    Ronen, Itamar
    NMR IN BIOMEDICINE, 2015, 28 (08) : 976 - 987
  • [37] Apparent diffusion coefficients of normal uterus in premenopausal women with 3 T MRI
    Kuang, F.
    Chen, Z.
    Zhong, Q.
    Fu, L.
    Ma, M.
    CLINICAL RADIOLOGY, 2013, 68 (05) : 455 - 460
  • [38] In vivo Correlation Tensor MRI reveals microscopic kurtosis in the human brain on a clinical 3T scanner
    Novello, Lisa
    Henriques, Rafael Neto
    Ianus, Andrada
    Feiweier, Thorsten
    Shemesh, Noam
    Jovicich, Jorge
    NEUROIMAGE, 2022, 254
  • [39] Considerations in applying compressed sensing to in vivo phosphorus MR spectroscopic imaging of human brain at 3T
    Gokce Hale Hatay
    Muhammed Yildirim
    Esin Ozturk-Isik
    Medical & Biological Engineering & Computing, 2017, 55 : 1303 - 1315
  • [40] Considerations in applying compressed sensing to in vivo phosphorus MR spectroscopic imaging of human brain at 3T
    Hatay, Gokce Hale
    Yildirim, Muhammed
    Ozturk-Isik, Esin
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (08) : 1303 - 1315