Distinguishing benign from malignant adrenal masses: Multi-detector row CT protocol with 10-minute delay

被引:168
|
作者
Blake, MA
Kalra, MK
Sweeney, AT
Lucey, BC
Maher, MM
Sahani, DV
Halpern, EF
Mueller, PR
Hahn, PF
Boland, GW
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Div Abdominal Imaging & Intervent, Boston, MA 02114 USA
[2] St Elizabeths Med Ctr, Dept Med, Div Endocrinol, Boston, MA USA
关键词
D O I
10.1148/radiol.2382041514
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To retrospectively evaluate the accuracy of precontrast attenuation, relative percentage washout (RPW), and absolute percentage washout (APW) in distinguishing benign from malignant adrenal masses at multi- detector row computed tomography (CT). Materials and Methods: This HIPAA-compliant retrospective study had institutional review board approval; the need for informed consent was waived. One hundred twenty-two adrenal masses were evaluated in 99 patients (51 men, 48 women; age range, 37-86 years) who had undergone CT performed according to the study protocol and who either were given a pathologic diagnosis or underwent follow-up imaging. Unenhanced images were obtained before administration of 120 mL of an intravenous contrast agent with a 75-second scan delay. Delayed images were obtained after 10 minutes. RPW and APW were computed. Receiver operating characteristic (ROC) analysis was performed to compare mean attenuation and both RPW and APW. Analysis was first performed with the exclusion of pheochromocytomas, myelolipomas, and cysts. Precontrast attenuation criteria specific for benignity or malignancy were determined, and ROC analysis of results for the entire nonpheochromocytoma group was then performed. Results: By using an RPW of 37.5% and excluding cysts and myelolipomas, all malignant lesions were detected with a sensitivity of 100% (17 of 1.7 lesions) and a specificity of 95% (90 of 95 lesions). Area under the binomial ROC curve (A(z)) values were 0.912, 0.985, and 0.892 for precontrast attenuation, RPW, and APW, respectively. Precontrast attenuation, of less than 0 or more than 43 HU indicated benign and malignant entities, respectively. Incorporation of these criteria into the APW analysis yielded a sensitivity of 100% (17 of 17 lesions) and a specificity of 98% (93 of 95 lesions) for a threshold washout value of 52.0%. This attenuation-corrected APW generated the greatest A. value (ie, 0.988). Combining all the information available from the protocol yielded a sensitivity of 100% (17 of 17 lesions) and a specificity of 98% (98 of 100 lesions) for differentiating benign from malignant masses. Conclusion: Precontrast attenuation of less than 0 HU supercedes the washout profile in the evaluation of an individual adrenal mass. Noncalcified, nonhemorrhagic adrenal lesions with precontrast attenuation of more than 43 HU should be considered suspicious for malignancy. (c) RSNA, 2005
引用
收藏
页码:578 / 585
页数:8
相关论文
共 45 条
  • [21] Distinguishing metastases from benign adrenal masses: what can CT texture analysis do?
    Shi, Bing
    Zhang, Gu-Mu-Yang
    Xu, Min
    Jin, Zheng-Yu
    Sun, Hao
    ACTA RADIOLOGICA, 2019, 60 (11) : 1553 - 1561
  • [22] Evaluation of living liver donors with an all-inclusive 3D multi-detector row CT protocol
    Schroeder, T
    Radtke, A
    Kuehl, H
    Debatin, JF
    Malagó, M
    Ruehm, SG
    RADIOLOGY, 2006, 238 (03) : 900 - 910
  • [23] Hepatocellular carcinoma: Prediction of blood supply from an internal mammary artery with multi-detector row CT
    Kim, Hyo-Cheol
    Chung, Jin Wook
    Jae, Hwan Jun
    Jeon, Ung Bae
    Son, Kyu Ri
    Park, Jae Hyung
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (10) : 1419 - 1425
  • [24] Comprehensive evaluation of patients suspected with deep vein thrombosis using indirect CT venography with multi-detector row technology: from protocol to interpretation
    Lin, Yen-Ting
    Tsai, I-Chen
    Tsai, Wei-Lin
    Chen, Min-Chi
    Lin, Pao-Chun
    Chan, Si-Wa
    Chen, Clayton Chi-Chang
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 : 311 - 322
  • [25] Comprehensive evaluation of patients suspected with deep vein thrombosis using indirect CT venography with multi-detector row technology: from protocol to interpretation
    Yen-Ting Lin
    I-Chen Tsai
    Wei-Lin Tsai
    Min-Chi Chen
    Pao-Chun Lin
    Si-Wa Chan
    Clayton Chi-Chang Chen
    The International Journal of Cardiovascular Imaging, 2010, 26 : 311 - 322
  • [26] ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality
    Hong, C
    Becker, CR
    Huber, A
    Schoepf, UJ
    Ohnesorge, B
    Knez, A
    Brüning, R
    Reiser, MF
    RADIOLOGY, 2001, 220 (03) : 712 - 717
  • [27] Abdominal aortic aneurysms at multi-detector row helical CT: Optimization with interactive determination of scanning delay and contrast medium dose
    Ho, LM
    Nelson, RC
    Thomas, J
    Gimenez, EI
    DeLong, DM
    RADIOLOGY, 2004, 232 (03) : 854 - 859
  • [28] Accuracy of chemical shift MRI in distinguishing benign from malignant adrenal masses in patients with potentially resectable bronchogenic carcinoma
    Khorasani, R
    Tuncali, K
    Swanson, S
    Tempany, CM
    Sica, GT
    Silverman, SG
    RADIOLOGY, 1998, 209P : 411 - 411
  • [29] Incidental adrenal masses on F-18 FDG PET/CT in oncologic patients: Differentiation malignant from benign masses
    Lee, Hong Je
    Song, Bon Il
    Kang, Sung Min
    Seo, Ji-Hyoung
    Lee, Sang-Woo
    Yoo, Jeongsoo
    Ahn, Byeong-Cheol
    Lee, Jaetae
    Lee, Kyu Bo
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [30] Acute appendicitis: Added diagnostic value of coronal reformations from isotropic voxels at multi-detector row CT
    Paulson, EK
    Harris, JP
    Jaffe, TA
    Haugan, PA
    Nelson, RC
    RADIOLOGY, 2005, 235 (03) : 879 - 885