Hybrid System of Unbonded Post-Tensioned CLT Panels and Light-Frame Wood Shear Walls

被引:37
|
作者
Tu Xuan Ho [1 ]
Thang Nguyen Dao [1 ]
Aaleti, Sriram [1 ]
van de Lindt, John W. [2 ]
Rammer, Douglas R. [3 ]
机构
[1] Univ Alabama, Dept Civil Construct & Environm Engn, Tuscaloosa, AL 35487 USA
[2] Colorado State Univ, Infrastruct, Dept Civil & Environm Engn, Ft Collins, CO 80523 USA
[3] Forest Prod Lab, 1 Gifford Pinchot Dr, Madison, WI 53726 USA
基金
美国国家科学基金会;
关键词
Cross-laminated timber (CLT); Post-tensioned; Light frame wood shear wall; Hybrid system; Cyclic loads; Incremental dynamic analysis (IDA); Wood structures; CONCRETE FRAMES; MODEL;
D O I
10.1061/(ASCE)ST.1943-541X.0001665
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cross-laminated timber (CLT) is a relatively new type of massive timber system that has shown to possess excellent mechanical properties and structural behavior in building construction. When post-tensioned with high-strength tendons, CLT panels perform well under cyclic loadings because of two key characteristics: their rocking behavior and self-centering capacity. Although post-tensioned rocking CLT panels can carry heavy gravity loads, resist lateral loads, and self-center after a seismic event, they are heavy and form a pinched hysteresis, thereby limiting energy dissipation. Conversely, conventional light-frame wood shear walls (LiFS) provide a large amount of energy dissipation from fastener slip and, as their name implies, are lightweight, thereby reducing inertial forces during earthquakes. The combination of these different lateral behaviors can help improve the performance of buildings during strong ground shaking, but issues of deformation compatibility exist. This study presents the results of a numerical study to examine the behavior of post-tensioned CLT walls under cyclic loadings. A well-known 10-parameter model was applied to simulate the performance of a CLT-LiFS hybrid system. The post-tensioned CLT wall model was designed on the basis of a modified monolithic beam analogy that was originally developed for precast concrete-jointed ductile connections. Several tests on post-tensioned CLT panels and hybrid walls were implemented at the Large Scale Structural Lab at the University of Alabama to validate the numerical model, and the results showed very good agreement with the numerical model. Finally, incremental dynamic analysis on system level models was compared with conventional light-frame wood system models. (C) 2016 American Society of Civil Engineers.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Structural characteristics of light-frame wood shear walls with various construction detailing
    Bagheri, M. M.
    Doudak, G.
    ENGINEERING STRUCTURES, 2020, 205
  • [32] Lateral response of post-tensioned pendulum shear walls
    Silva, P. F.
    Lagler, C.
    Burgueno, R.
    STRUCTURES, 2024, 67
  • [33] Seismic Behavior of Hybrid Post-Tensioned Cast in Place Concrete Shear Walls
    Anis Shatnawi
    Sara G. Abdallah
    Bashar Tarawneh
    Arabian Journal for Science and Engineering, 2019, 44 : 4095 - 4109
  • [34] Experimental study of punching shear in post-tensioned slabs with unbonded tendons
    Choi, Seung-Ho
    Hwang, Jin-Ha
    Han, Sun-Jin
    Joo, Hyo-Eun
    Kim, Jae-Hyun
    Kim, Kang Su
    STRUCTURAL ENGINEERING AND MECHANICS, 2021, 79 (04) : 507 - 516
  • [35] Shear behavior of unbonded post-tensioned segmental beams with dry joints
    Turmo, J
    Ramos, G
    Aparicio, AC
    ACI STRUCTURAL JOURNAL, 2006, 103 (03) : 409 - 417
  • [36] In-plane flexural strength of unbonded post-tensioned concrete masonry walls
    Hassanli, Reza
    ElGawady, Mohamed A.
    Mills, Julie E.
    ENGINEERING STRUCTURES, 2017, 136 : 245 - 260
  • [38] Experimental Lateral Load Response of Unbonded Post-Tensioned Precast Concrete Walls
    Perez, Felipe J.
    Pessiki, Stephen
    Sause, Richard
    ACI STRUCTURAL JOURNAL, 2013, 110 (06) : 1045 - 1055
  • [39] Unbonded Tendon Stresses in Post-Tensioned Concrete Walls at Nominal Flexural Strength
    Henry, Richard S.
    Sri Sritharan
    Ingham, Jason M.
    ACI STRUCTURAL JOURNAL, 2012, 109 (02) : 171 - 181
  • [40] Seismic performance assessment of conventional CLT shear wall structures and post-tensioned CLT shear wall structures
    Sun, Xiaofeng
    He, Minjuan
    Li, Zheng
    Lam, Frank
    ENGINEERING STRUCTURES, 2019, 196