Metal-organic framework MIL-100(Fe) as the stationary phase for both normal-phase and reverse-phase high performance liquid chromatography

被引:110
|
作者
Fu, Yan-Yan [1 ,2 ]
Yang, Cheng-Xiong [1 ,2 ]
Yan, Xiu-Ping [1 ,2 ]
机构
[1] Nankai Univ, State Key Lab Med Chem Biol, Coll Chem, Tianjin 300071, Peoples R China
[2] Nankai Univ, Res Ctr Analyt Sci, Coll Chem, Tianjin 300071, Peoples R China
基金
中国国家自然科学基金;
关键词
Metal-organic frameworks; Stationary phase; High performance liquid chromatography; Normal phase; Reverse phase; Isomers; COATED CAPILLARY COLUMNS; SELECTIVE ADSORPTION; XYLENE ISOMERS; MOBILE-PHASE; SEPARATION; ALKYLAROMATICS; ETHYLBENZENE; MIL-101(CR); AROMATICS; ALKANES;
D O I
10.1016/j.chroma.2012.12.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Metal-organic framework MIL-100(Fe) was explored as a novel stationary phase for both normal-phase and reverse-phase high performance liquid chromatography. Two groups of analytes (benzene, toluene, ethylbenzene, naphthalene and 1-chloronaphthalene; aniline, acetanilide, 2-nitroaniline and 1-naphthylamine) were used to test the separation performance of MIL-100(Fe) in the reverse-phase mode, while the isomers of chloroaniline or toluidine were employed to evaluate its performance in the normal-phase mode. The MIL-100(Fe) packed column gave a baseline separation of all the tested analytes with good precision. The separation was controlled by negative enthalpy change and entropy change in the reverse-phase mode, but positive enthalpy change and entropy change in the normal-phase mode. The relative standard deviations of retention time, peak area, peak height, and half peak width for eleven replicate separations of the tested analytes were 0.2-0.7%, 0.5-3.6%, 0.6-2.3% and 0.8-1.7%, respectively. The mesoporous cages, accessible windows, excellent chemical and solvent stability, metal active sites and aromatic pore walls make MIL-100(Fe) a good candidate as a novel stationary phase for both normal-phase and reverse-phase high performance liquid chromatography. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 50 条
  • [1] Metal-organic frameworks for reverse-phase high-performance liquid chromatography
    Liu, Shan-Shan
    Yang, Cheng-Xiong
    Wang, Shan-Wei
    Yan, Xiu-Ping
    [J]. ANALYST, 2012, 137 (04) : 816 - 818
  • [2] Chiral Separation and Determination of Etoxazole Enantiomers in Vegetables by Normal-Phase and Reverse-Phase High Performance Liquid Chromatography
    Zhang, Ping
    He, Yuhan
    Wang, Sheng
    Shi, Dongmei
    Xu, Yangyang
    Yang, Furong
    Wang, Jianhao
    He, Lin
    [J]. MOLECULES, 2020, 25 (14):
  • [3] Separation of anilines by a covalent triazine-triphenyl polymer as a stationary phase for their normal-phase and reverse-phase determination by high-performance liquid chromatography (HPLC)
    Yue, Zeyi
    Peng, Zifang
    Guo, Yun
    Zhang, Wenfen
    [J]. ANALYTICAL LETTERS, 2022, 55 (17) : 2764 - 2775
  • [4] Homochiral metal-organic framework used as a stationary phase for high-performance liquid chromatography
    Kong, Jiao
    Zhang, Mei
    Duan, Ai-Hong
    Zhang, Jun-Hui
    Yang, Rui
    Yuan, Li-Ming
    [J]. JOURNAL OF SEPARATION SCIENCE, 2015, 38 (04) : 556 - 561
  • [5] Properties of microdispersed sintered nanodiamonds as a stationary phase for normal-phase high performance liquid chromatography
    Nesterenko, Pavel N.
    Fedyanina, Olga N.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (04) : 498 - 505
  • [6] SEPARATION OF TOCOPHEROL AND TOCOTRIENOL ISOMERS USING NORMAL-PHASE AND REVERSE-PHASE LIQUID-CHROMATOGRAPHY
    TAN, B
    BRZUSKIEWICZ, L
    [J]. ANALYTICAL BIOCHEMISTRY, 1989, 180 (02) : 368 - 373
  • [7] MICROBORE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED INTERFACE FOR NORMAL-PHASE OR REVERSE-PHASE LIQUID-CHROMATOGRAPHY
    KALASINSKY, KS
    SMITH, JAS
    KALASINSKY, VF
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (09) : 1969 - 1974
  • [8] Comparative Enantioseparation of Crufomate with Cellulose- and Amylose-based Chiral Stationary Phases on Reverse-Phase and Normal-Phase High-Performance Liquid Chromatography
    Chai, Tingting
    Wang, Xueqing
    Bie, Mei
    Dai, Shouhui
    Zhao, Hualin
    Yang, Shuming
    Qiu, Jing
    [J]. ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (02) : 797 - 802
  • [9] High performance liquid chromatography of substituted aromatics with the metal-organic framework MIL-100(Fe): Mechanism analysis and model-based prediction
    Qin, Weiwei
    Silvestre, Martin Eduardo
    Li, Yongli
    Franzreb, Matthias
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2016, 1432 : 84 - 91
  • [10] "Click" preparation of a chiral macrocycle-based stationary phase for both normal-phase and reversed-phase high performance liquid chromatography enantioseparation
    Zhang, You -Ping
    Li, Kuan
    Xiong, Ling-Xiao
    Wang, Bang-Jin
    Xie, Sheng-Ming
    Zhang, Jun -Hui
    Yuan, Li -Ming
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2022, 1683