Determination of Bedaquiline in Human Serum Using Liquid Chromatography-Tandem Mass Spectrometry

被引:27
|
作者
Alffenaar, Jan-Willem C. [1 ]
Bolhuis, Mathieu [1 ]
van Hateren, Kai [1 ]
Sturkenboom, Marieke [1 ]
Akkerman, Onno [2 ]
de Lange, Wiel [2 ]
Greijdanus, Ben [1 ]
van der Werf, Tjip [2 ,3 ]
Touw, Daan [1 ,4 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Clin Pharm & Pharmacol, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Pulm Dis & TB, Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Internal Med, Groningen, Netherlands
[4] Univ Groningen, Univ Ctr Pharm, Sect Pharmacokinet Toxicol & Targeting, Groningen, Netherlands
关键词
ACQUIRED DRUG-RESISTANCE; DIARYLQUINOLINE TMC207; BACTERICIDAL ACTIVITY; ICP-MS; TUBERCULOSIS; PHARMACOKINETICS; HPLC; MOXIFLOXACIN; RIFAPENTINE; MANAGEMENT;
D O I
10.1128/AAC.00276-15
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Bedaquiline, a diarylquinoline for the treatment of multidrug-resistant tuberculosis (TB), relies on exposure-dependent killing. As data on drug exposure in specific populations are scarce, pharmacokinetic studies may be of interest. No simple and robust validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been reported to date. Therefore, a new method using a quadrupole mass spectrometer was developed for analysis of bedaquiline and N-monodesmethyl bedaquiline (M2) in human serum, using deuterated bedaquiline as the internal standard. The calibration curve was linear over a range of 0.05 (lower limit of quantification [LLOQ]) to 6.00 mg/liter for both bedaquiline and M2, with correlation coefficient values of 0.997 and 0.999, respectively. The calculated accuracy ranged from 1.9% to 13.6% for bedaquiline and 2.9% to 8.5% for M2. Within-run precision ranged from 3.0% to 7.2% for bedaquiline and 3.1% to 5.2% for M2, and between-run precision ranged from 0.0% to 4.3% for bedaquiline and 0.0% to 4.6% for M2. Evaluation of serum concentrations in a patient receiving bedaquiline showed high levels at the end of treatment, reflecting accumulation of the drug. More observational pharmacokinetic data are needed to relate altered drug concentrations to clinical outcome or adverse drug effects. A simple LC-MS/MS method to quantify bedaquiline and M2 levels in human serum using a deuterated internal standard has been validated. This method can be used in clinical studies and daily practice.
引用
收藏
页码:5675 / 5680
页数:6
相关论文
共 50 条
  • [1] Determination of Lamotrigine in Human Serum By Liquid Chromatography-Tandem Mass Spectrometry
    Lee, W.
    Yoon, S.
    Park, Y.
    Suh, B.
    Kwon, O. H.
    [J]. CLINICAL CHEMISTRY, 2009, 55 (06) : A261 - A261
  • [2] Determination of Tirofiban in human serum by liquid chromatography-tandem mass spectrometry
    Oertel, R
    Köhler, A
    Koster, A
    Kirch, W
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (01): : 181 - 185
  • [3] Quantitative determination of methylnaltrexone in human serum using liquid chromatography-tandem mass spectrometry
    Oswald, Stefan
    Schumacher, Gitta
    Siegmund, Werner
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (05) : 1079 - 1084
  • [4] Determination of evodiamine and rutecarpine in human serum by liquid chromatography-tandem mass spectrometry
    Wen, Dawei
    Li, Chenchen
    Liu, Yuping
    Liao, Yiping
    Liu, Huwei
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (06) : 1075 - 1081
  • [5] Determination of serum amantadine by liquid chromatography-tandem mass spectrometry
    Arndt, T
    Guessregen, B
    Hohl, A
    Reis, J
    [J]. CLINICA CHIMICA ACTA, 2005, 359 (1-2) : 125 - 131
  • [6] Determination of testosterone in serum by liquid chromatography-tandem mass spectrometry
    Turpeinen, U.
    Linko, S.
    Itkonen, O.
    Hamalainen, E.
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2008, 68 (01): : 50 - 57
  • [7] Determination of aldosterone in serum by liquid chromatography-tandem mass spectrometry
    Turpeinen, Ursula
    Hamalainen, Esa
    Stenman, Ulf-Hakan
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 113 - 118
  • [8] Simultaneous determination of androstenedione and testosterone in human serum by liquid chromatography-tandem mass spectrometry
    Gallagher, L. M.
    Owen, L. J.
    Keevil, B. G.
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2007, 44 : 48 - 56
  • [9] Determination of Cefotiam in Human Plasma Using Liquid Chromatography-Tandem Mass Spectrometry
    Du Ping
    Li Peng-Fei
    Liu Hong-Chuan
    Yu Wei-Yue
    Liu Li-Hong
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 44 (06) : 876 - 881
  • [10] Determination of scopolamine in human serum and microdialysis samples by liquid chromatography-tandem mass spectrometry
    Oertel, R
    Richter, K
    Ebert, U
    Kirch, W
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2001, 750 (01): : 121 - 128