A high precision fundamental frequency measurement method based on FPGA

被引:0
|
作者
Wang Yifan [1 ]
Chen Kai [1 ]
Xu Bo [1 ]
Yang Yunpeng [1 ]
Luan Yun [1 ]
机构
[1] Univ Elect Sci & Technol China, Sch Automat Engn, Chengdu 611731, Peoples R China
基金
中国国家自然科学基金;
关键词
fundamental frequency; harmonics; FFT; period measurement; FPGA; power analyzer;
D O I
10.1109/icemi46757.2019.9101426
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Accurate fundamental frequency measurement has a significant role in synchronous sampling and power parameter analysis. However, the large amount of harmonics appearing in circuits makes it difficult to measure the fundamental frequency. In this work, we propose a fundamental frequency measurement architecture that combines. FFT algorithm with period measurement method. This method can reduce the frequency resolution limitation in FFT between sampling rates and calculating length. This integrated method is appropriate to measure the fundamental frequency of signal that contains a large amount of harmonics. :Experimental results show that the frequency of signal with large amplitude harmonics can be measured accurately by using the proposed structure.
引用
收藏
页码:254 / 260
页数:7
相关论文
共 50 条
  • [21] FPGA-based High-precision Measurement Algorithm for the Ultrasonic Echo Time of Flight
    王伯雄
    张金
    [J]. Journal of Measurement Science and Instrumentation, 2010, 1 (02) : 103 - 107
  • [22] DESIGN OF EQUAL PRECISION FREQUENCY MEASURING SYSTEM BASED ON FPGA
    Yang, Huibao
    [J]. INTERNATIONAL SYMPOSIUM ON COMPUTER SCIENCE & TECHNOLOGY, PROCEEDINGS, 2009, : 626 - 628
  • [23] Frequency Meter with Equal Precision Based FPGA plus MCU
    Wang, Peng
    Yan, Changjia
    Niu, Tong
    Fang, Xue
    Jin, Zhipeng
    Guan, Boshi
    [J]. INTERNATIONAL CONFERENCE MACHINERY, ELECTRONICS AND CONTROL SIMULATION, 2014, 614 : 308 - 311
  • [24] A High Precision Proton Magnetometer Based on a Multi-Channel Frequency Measurement
    Liu, Huan
    Dong, Haobin
    Ge, Jian
    Bai, Bingjie
    [J]. 2016 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, 2016, : 837 - 841
  • [25] Embedded High-Precision Frequency-Based Capacitor Measurement System
    Welter, Loic
    Dreux, Philippe
    Portal, Jean-Michel
    Aziza, Hassen
    [J]. PROCEEDINGS OF THE 2013 IEEE 19TH INTERNATIONAL ON-LINE TESTING SYMPOSIUM (IOLTS), 2013, : 116 - 121
  • [26] Research on high precision frequency measurement method for large dynamic range periodic signal
    Guo, XY
    Cheng, XC
    Wang, YK
    Su, SJ
    [J]. ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 2717 - 2720
  • [27] High-Precision Roll Measurement Method Based on Laser Polarization
    Long, Fei
    Zheng, Fajia
    Jia, Peizhi
    Xia, Xing
    Feng, Qibo
    [J]. INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2024, 25 (10) : 2099 - 2110
  • [28] Development of high frequency and high precision phase measurement instrument based on AD9901
    Institute of Modern Physics, CAS, P.O. Box 31, Lanzhou 730000, China
    不详
    [J]. Hedianzixue Yu Tance Jishue, 2007, 5 (901-904):
  • [29] A frequency measurement method based on optimal multi-average for increasing proton magnetometer measurement precision
    Tan, Chao
    Wang, Jiacheng
    Li, Zongliao
    [J]. MEASUREMENT, 2019, 135 : 418 - 423
  • [30] Analysis of High Precision Moment of Inertia Measurement Method Based on Torsion Pendulum Method
    Li, Haoyue
    Xu, Yong
    Ding, Jiuhui
    Zhai, Kangrui
    [J]. 2021 PROCEEDINGS OF THE 40TH CHINESE CONTROL CONFERENCE (CCC), 2021, : 6651 - 6655