Vibro stone column installation and its effect on ground improvement

被引:0
|
作者
Kirsch, F. [1 ]
机构
[1] GuD Geotech & Dynam Consult GmbH, Berlin, Germany
来源
Numerical Modelling of Construction Processes in Geotechnical Engineering for Urban Environment | 2006年
关键词
D O I
暂无
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Results of installation accompanying measurements of the in situ stresses, the ground stiffness and the ground surface vibrations in various test fields are presented. Following the installation, the stone columns are subjected to group loading whilst the instrumentation remains active including load pressure cells and settlement transducers. The results show significant alteration of the stress state and the soil stiffness during penetration of the depth vibrator and the subsequent stone column installation. Two major effects can be distinguished: the displacement of the ground due to the creation of the stone column body and the ground vibration with associated changes within the soil due to the movements of the depth vibrator. The results of the measurements are used to model the installation effects in numerical analyses using the finite element method. Comparison between the numerical results and the findings of the measurements as well as the load test results are used to calibrate this numerical model. Finally parametric studies are undertaken to estimate the additional improvement effect of the installation process on the total ground improvement factor for vibro stone column measures.
引用
收藏
页码:115 / 124
页数:10
相关论文
共 50 条
  • [31] Practice of using vibro-replacement stone column for improving uneven ground base composed of soil and weathered rock stratum
    Zhang, Fengwen
    Chen, Guanggang
    Zhao, Guozhong
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2000, 21 (02): : 68 - 74
  • [32] Ground vibrations from dynamic replacement column installation
    Hackney, Greg
    Australian Geomechanics Journal, 2011, 46 (01): : 23 - 30
  • [33] Vibro-replacement Stone Column Treating Silty Sand soil Subgrade
    Yuan, Yuqing
    Li, Wei
    Li, Xuechan
    Guo, Tao
    ADVANCES IN CIVIL ENGINEERING II, PTS 1-4, 2013, 256-259 : 1060 - +
  • [34] Study on composite model for vibro-replacement stone column foundation by FEM
    Fu, Shao-Jun
    Wang, Man
    Yantu Lixue/Rock and Soil Mechanics, 2008, 29 (02): : 375 - 380
  • [35] Laboratory assessment of the effect of vibro-replacement ground improvement on the mechanical response of natural silt
    Verma, Priyesh
    Wijewickreme, Dharma
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2023, 173
  • [36] Numerical Modelling of Stone Column Installation Effects on Performance of Circular Footing
    Benmebarek S.
    Remadna A.
    Benmebarek N.
    International Journal of Geosynthetics and Ground Engineering, 2018, 4 (3)
  • [37] Effect of Inter-Column Spacing on Soil Stresses due to Vibro-Installed Stone Columns: Interesting Findings
    Elshazly, Hesham
    Elkasabgy, Mohamed
    Elleboudy, Azza
    GEOTECHNICAL AND GEOLOGICAL ENGINEERING, 2008, 26 (02) : 225 - 236
  • [38] Encased Stone Columns for Soft Ground Improvement
    Dutta, Sushovan
    Nadaf, M. B.
    Birali, Ram Rathan Lal
    Mandal, J. N.
    GEO-CHICAGO 2016: SUSTAINABLE GEOENVIRONMENTAL SYSTEMS, 2016, (271): : 746 - 755
  • [39] Analytical and experimental study of the improvement of stone column composite foundations under shaking effect
    Arefpanah, Semko
    Sharafi, Alireza
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-GROUND IMPROVEMENT, 2023, 177 (04) : 255 - 272
  • [40] Soil improvement by vibro compaction in sandy gravel for ground water reduction
    Sidak, N
    COMPACTION OF SOILS, GRANULATES AND POWDERS, 2000, 3 : 23 - 32