Technical considerations in MR angiography: An image-based guide

被引:22
|
作者
Morelli, John N. [1 ]
Gerdes, Clint M. [1 ]
Schmitt, Peter [2 ]
Ai, Tao [3 ]
Saettele, Megan R. [4 ]
Runge, Val M. [5 ]
Attenberger, Ulrike I. [6 ]
机构
[1] Texas A&M Univ, Hlth Sci Ctr, Scott & White Clin & Hosp, Dept Radiol, Temple, TX USA
[2] Siemens Healthcare Erlangen, Bavaria, Germany
[3] Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Radiol, Wuhan 430074, Peoples R China
[4] Univ Missouri, St Lukes Hosp, Dept Radiol, Kansas City, MO 64110 USA
[5] Univ Texas Med Branch, Dept Radiol, Galveston, TX 77555 USA
[6] Heidelberg Univ, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, Mannheim, Germany
关键词
magnetic resonance angiography; magnetic resonance venography; gadolinium chelates; parallel imaging; 3; T; MAGNETIC-RESONANCE-ANGIOGRAPHY; INTENSITY-PROJECTION ALGORITHMS; CONTRAST-ENHANCED MRA; RENAL-ARTERY STENOSIS; STATE FREE PRECESSION; BRAIN GLIOMA MODEL; INTRACRANIAL ANEURYSMS; T; GADOPENTETATE DIMEGLUMINE; GADOBENATE DIMEGLUMINE;
D O I
10.1002/jmri.24174
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As the complexity of the magnetic resonance angiography (MRA) techniques grows, it becomes more difficult for the practicing radiologist to appreciate the physical principles underlying these studies. Nevertheless, such an understanding is requisite for improving clinical image quality. As radiologists are most accustomed to dealing with medical images in everyday practice, it seems natural that an image-based approach to teaching MRA physics, rather than complex mathematical equations or pulse sequence diagrams, would be preferable. This article adopts such an approach. Simple ways to improve MRA image quality are emphasized along with new technologies and their physical basis. The ultimate goal of the article is to facilitate the practicing radiologist becoming more aware of the variety of MR techniques available, being more confident in modifying sequence parameters to improve image quality and reduce contrast dose, and understanding the basis behind newer MRA techniques. J. Magn. Reson. Imaging 2013;37:13261341. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1326 / 1341
页数:16
相关论文
共 50 条
  • [41] MR enteroclysis: technical considerations and clinical applications
    Nicholas Gourtsoyiannis
    Nickolas Papanikolaou
    John Grammatikakis
    Panos Prassopoulos
    [J]. European Radiology, 2002, 12 : 2651 - 2658
  • [42] Postoperative MR Imaging of Joints Technical Considerations
    Burke, Christopher J.
    Khodarahmi, Iman
    Fritz, Jan
    [J]. MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2022, 30 (04) : 583 - 600
  • [43] MR-IMAGING OF THE MUSCULOSKELETAL SYSTEM - TECHNICAL CONSIDERATIONS FOR ENHANCING IMAGE QUALITY AND DIAGNOSTIC YIELD
    RUBIN, DA
    KNEELAND, JB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (05) : 1155 - 1163
  • [44] MR image-based radiomics to differentiate type Ι and type ΙΙ epithelial ovarian cancers
    Junming Jian
    Yong’ai Li
    Perry J. Pickhardt
    Wei Xia
    Zhang He
    Rui Zhang
    Shuhui Zhao
    Xingyu Zhao
    Songqi Cai
    Jiayi Zhang
    Guofu Zhang
    Jingxuan Jiang
    Yan Zhang
    Keying Wang
    Guangwu Lin
    Feng Feng
    Xiaodong Wu
    Xin Gao
    Jinwei Qiang
    [J]. European Radiology, 2021, 31 : 403 - 410
  • [45] Optimizing maternal fat suppression with constrained image-based shimming in fetal MR
    Gaspar, Andreia S.
    Nunes, Rita G.
    Ferrazzi, Giulio
    Hughes, Emer J.
    Hutter, Jana
    Malik, Shaihan J.
    McCabe, Laura
    Baruteau, Kelly P.
    Rutherford, Mary A.
    Hajnal, Joseph V.
    Price, Anthony N.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (01) : 477 - 485
  • [46] MR image-based radiomics to differentiate type Ι and type ΙΙ epithelial ovarian cancers
    Jian, Junming
    Li, Yongai
    Pickhardt, Perry J.
    Xia, Wei
    He, Zhang
    Zhang, Rui
    Zhao, Shuhui
    Zhao, Xingyu
    Cai, Songqi
    Zhang, Jiayi
    Zhang, Guofu
    Jiang, Jingxuan
    Zhang, Yan
    Wang, Keying
    Lin, Guangwu
    Feng, Feng
    Wu, Xiaodong
    Gao, Xin
    Qiang, Jinwei
    [J]. EUROPEAN RADIOLOGY, 2021, 31 (01) : 403 - 410
  • [47] Whole-heart coronary MR angiography using image-based navigation for the detection of coronary anomalies in adult patients with congenital heart disease
    Henningsson, Markus
    Hussain, Tarique
    Vieira, Miguel S.
    Greil, Gerald F.
    Smink, Jouke
    v Ensbergen, Gerald
    Beck, Gabrielle
    Botnar, Rene M.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (04) : 947 - 955
  • [48] TECHNICAL FACTORS IN MR IMAGE QUALITY
    KOEHLER, PR
    DANIELS, DL
    WILLIAMS, AL
    HAUGHTON, VM
    [J]. NEURORADIOLOGY, 1986, 28 (01) : 74 - 77
  • [49] MR angiography of the fingers: Technical constraints and clinical applications
    Drape, J
    Argaud, C
    Diche, T
    Revelon, GI
    Godefroy, DA
    Chevrot, A
    [J]. RADIOLOGY, 2001, 221 : 611 - 611
  • [50] SOME TECHNICAL CONSIDERATIONS IN PURCHASING A DIGITAL ANGIOGRAPHY SYSTEM