Technical considerations in MR angiography: An image-based guide

被引:22
|
作者
Morelli, John N. [1 ]
Gerdes, Clint M. [1 ]
Schmitt, Peter [2 ]
Ai, Tao [3 ]
Saettele, Megan R. [4 ]
Runge, Val M. [5 ]
Attenberger, Ulrike I. [6 ]
机构
[1] Texas A&M Univ, Hlth Sci Ctr, Scott & White Clin & Hosp, Dept Radiol, Temple, TX USA
[2] Siemens Healthcare Erlangen, Bavaria, Germany
[3] Huazhong Univ Sci & Technol, Tongji Med Coll, Tongji Hosp, Dept Radiol, Wuhan 430074, Peoples R China
[4] Univ Missouri, St Lukes Hosp, Dept Radiol, Kansas City, MO 64110 USA
[5] Univ Texas Med Branch, Dept Radiol, Galveston, TX 77555 USA
[6] Heidelberg Univ, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, Mannheim, Germany
关键词
magnetic resonance angiography; magnetic resonance venography; gadolinium chelates; parallel imaging; 3; T; MAGNETIC-RESONANCE-ANGIOGRAPHY; INTENSITY-PROJECTION ALGORITHMS; CONTRAST-ENHANCED MRA; RENAL-ARTERY STENOSIS; STATE FREE PRECESSION; BRAIN GLIOMA MODEL; INTRACRANIAL ANEURYSMS; T; GADOPENTETATE DIMEGLUMINE; GADOBENATE DIMEGLUMINE;
D O I
10.1002/jmri.24174
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As the complexity of the magnetic resonance angiography (MRA) techniques grows, it becomes more difficult for the practicing radiologist to appreciate the physical principles underlying these studies. Nevertheless, such an understanding is requisite for improving clinical image quality. As radiologists are most accustomed to dealing with medical images in everyday practice, it seems natural that an image-based approach to teaching MRA physics, rather than complex mathematical equations or pulse sequence diagrams, would be preferable. This article adopts such an approach. Simple ways to improve MRA image quality are emphasized along with new technologies and their physical basis. The ultimate goal of the article is to facilitate the practicing radiologist becoming more aware of the variety of MR techniques available, being more confident in modifying sequence parameters to improve image quality and reduce contrast dose, and understanding the basis behind newer MRA techniques. J. Magn. Reson. Imaging 2013;37:13261341. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1326 / 1341
页数:16
相关论文
共 50 条
  • [1] 3D image-based navigators for coronary MR angiography
    Addy, Nii Okai
    Ingle, R. Reeve
    Luo, Jieying
    Baron, Corey A.
    Yang, Phillip C.
    Hu, Bob S.
    Nishimura, Dwight G.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (05) : 1874 - 1883
  • [2] MR and CT angiography of the pelvis: Clinical and technical considerations
    Flora, L
    Yamashita, Y
    Takahashi, M
    [J]. CRITICAL REVIEWS IN DIAGNOSTIC IMAGING, 1999, 40 (06) : 327 - 360
  • [3] Technical note: MR image-based synthesis CT for CyberKnife robotic stereotactic radiosurgery
    Jiao, Shengxiu
    Zhao, Xiaoqian
    Zhou, Peng
    Geng, Mingying
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (05):
  • [4] Accelerated isotropic resolution 3D image-based navigators for coronary MR angiography
    Nii O Addy
    Jieying Luo
    R Reeve Ingle
    Bob S Hu
    Dwight G Nishimura
    [J]. Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [5] A New Framework for Interleaved Scanning in Cardiovascular MR: Application to Image-Based Respiratory Motion Correction in Coronary MR Angiography
    Henningsson, Markus
    Mens, Giel
    Koken, Peter
    Smink, Jouke
    Botnar, Rene M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (02) : 692 - 696
  • [6] An Image-based Approach to MR Artifacts in Neuroradiology
    Morelli, J.
    Runge, V.
    Ai, F.
    Vu, L.
    Nitz, W.
    Schmeets, S.
    Garg, V.
    Desai, S.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [7] Reproducibility of image-based computational models of intracranial aneurysm: a comparison between 3D rotational angiography, CT angiography and MR angiography
    Ren, Yuan
    Chen, Guo-Zhong
    Liu, Zhen
    Cai, Yan
    Lu, Guang-Ming
    Li, Zhi-Yong
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2016, 15
  • [8] Image-Based Information Guide on Mobile Devices
    Lee, Jimmy Addison
    Yow, Kin-Choong
    Sluzek, Andrzej
    [J]. ADVANCES IN VISUAL COMPUTING, PT II, PROCEEDINGS, 2008, 5359 : 346 - 355
  • [9] Reproducibility of image-based computational models of intracranial aneurysm: a comparison between 3D rotational angiography, CT angiography and MR angiography
    Yuan Ren
    Guo-Zhong Chen
    Zhen Liu
    Yan Cai
    Guang-Ming Lu
    Zhi-Yong Li
    [J]. BioMedical Engineering OnLine, 15
  • [10] Scene Location Guide by Image-Based Retrieval
    Jhuo, I-Hong
    Chen, Tsuhan
    Lee, D. T.
    [J]. ADVANCES IN MULTIMEDIA MODELING, PROCEEDINGS, 2010, 5916 : 196 - +