Conventional versus computer-assisted surgery in total knee arthroplasty: comparison at ten years follow-up

被引:26
|
作者
d'Amato, Michele [1 ]
Ensini, Andrea [1 ,2 ]
Leardini, Alberto [2 ]
Barbadoro, Paolo [1 ]
Illuminati, Andrea [1 ]
Belvedere, Claudio [2 ,3 ]
机构
[1] Ist Ortoped Rizzoli, Dept Orthopaed Surg, IRCCS, Via Barbiano 1-10, I-40136 Bologna, Italy
[2] Ist Ortoped Rizzoli, Movement Anal Lab, IRCCS, Via Barbiano 1-10, I-40136 Bologna, Italy
[3] Ist Ortoped Rizzoli, Movement Anal Lab & Funct Clin Evaluat Prostheses, Ctr Ric Codivilla Putti, Via Barbiano 1-10, I-40136 Bologna, Italy
关键词
Total knee arthroplasty; Computer-aided surgery; Surgical navigation; Clinical outcome; Long-term follow-up; CONTROLLED-TRIAL; NAVIGATION; ALIGNMENT; OUTCOMES; OSTEOARTHRITIS; REPLACEMENTS; KINEMATICS; PROSTHESES; AXIS;
D O I
10.1007/s00264-018-4114-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeComputer-assisted systems (CAS) for total knee arthroplasty (TKA) were expected to result in more accurate prosthesis implantation, better patient outcomes, and longer implant survival when compared to conventional instrumentation (CI). The aim of this study was to compare two groups of patients operated using CAS or CI at ten years follow-up.MethodsOne hundred twenty TKA patients, 60 using CAS and 60 using CI, were contacted after a decade for follow-up. Eligible patients received radiological examination to assess the lower-limb mechanical axis. They were also clinically assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the Knee Society Score for Knee (KSS-K) and Function (KSS-F) Scoring. Kaplan-Meier survival analysis was performed to assess revisions, not for post-traumatic reasons.ResultsIn CAS and CI groups, the lower-limb mechanical axis was 1.7 degrees 2.4 degrees and 1.5 degrees +/- 2.8 degrees, respectively; corresponding KOOS values were 82.3 +/- 14.3 and 78.6 +/- 14.4; KSS-K values were 85.9 +/- 11.1 and 85.0 +/- 9.7; KSS-F values were 82.2 +/- 19.3 and 83.8 +/- 18. For these assessments, the differences between the two groups were not statistically significant (p>0.05). Two CAS (3.8%) and three CI patients (5.7%) were revised. The Kaplan-Meier analysis showed no significant differences between the two groups.Conclusionsp id=Par4No significant differences were found at long-term follow-up in terms of radiographical-clinical outcomes and of implant survival between TKA operated using CAS or CI.
引用
收藏
页码:1355 / 1363
页数:9
相关论文
共 50 条
  • [1] Conventional versus computer-assisted surgery in total knee arthroplasty: comparison at ten years follow-up
    Michele d’Amato
    Andrea Ensini
    Alberto Leardini
    Paolo Barbadoro
    Andrea Illuminati
    Claudio Belvedere
    International Orthopaedics, 2019, 43 : 1355 - 1363
  • [2] Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique
    Bäthis, H
    Perlick, L
    Tingart, M
    Lüring, C
    Zurakowski, D
    Grifka, J
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05): : 682 - 687
  • [3] Minimally Invasive Computer-Assisted Total Knee Arthroplasty Compared With Conventional Total Knee Arthroplasty: A Prospective 9-Year Follow-Up
    Zhu, Meng
    Ang, Chia Liang
    Yeo, Seng Jin
    Lo, Ngai Nung
    Chia, Shi-Lu
    Chong, Hwei Chi
    JOURNAL OF ARTHROPLASTY, 2016, 31 (05): : 1000 - 1004
  • [4] Comparison of computer-assisted navigation and conventional instrumentation for bilateral total knee arthroplasty The outcomes at mid-term follow-up
    Hsu, Robert Wen-Wei
    Hsu, Wei-Hsiu
    Shen, Wun-Jer
    Hsu, Wei-Bin
    Chang, Shr-Hsin
    MEDICINE, 2019, 98 (47)
  • [5] Twelve-Year Follow-Up of Navigated Computer-Assisted Versus Conventional Total Knee Arthroplasty A Prospective Randomized Comparative Trial
    Cip, Johannes
    Obwegeser, Florian
    Benesch, Thomas
    Bach, Christian
    Ruckenstuhl, Paul
    Martin, Arno
    JOURNAL OF ARTHROPLASTY, 2018, 33 (05): : 1404 - 1411
  • [6] Clinical and Radiological Outcomes of Computer-Assisted versus Conventional Total Knee Arthroplasty at 5-Year Follow-Up: Is There Any Benefit?
    Chavez-Valladares, Sergio
    Trigueros-Larrea, Jose Maria
    Pais-Ortega, Sergio
    Gonzalez-Bedia, Maria Antonia
    Caballero-Garcia, Alberto
    Cordova, Alfredo
    Noriega-Gonzalez, David
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (09):
  • [7] Computer assisted total knee arthroplasty: 2.5 years follow-up of 200 cases
    Aletto, Cristian
    Zara, Arnaldo
    Notarfrancesco, Donato
    Maffulli, Nicola
    SURGEON-JOURNAL OF THE ROYAL COLLEGES OF SURGEONS OF EDINBURGH AND IRELAND, 2021, 19 (06): : E394 - E401
  • [8] Blood loss in computer-assisted mobile bearing total knee arthroplasty. A comparison of computer-assisted surgery with a conventional technique
    F. Conteduca
    F. Massai
    R. Iorio
    E. Zanzotto
    D. Luzon
    A. Ferretti
    International Orthopaedics, 2009, 33 : 1609 - 1613
  • [9] Blood loss in computer-assisted mobile bearing total knee arthroplasty. A comparison of computer-assisted surgery with a conventional technique
    Conteduca, F.
    Massai, F.
    Iorio, R.
    Zanzotto, E.
    Luzon, D.
    Ferretti, A.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (06) : 1609 - 1613
  • [10] Clinical Outcomes After Computer-assisted Versus Conventional Total Knee Arthroplasty
    Xie, Chunming
    Liu, Kai
    Xiao, Luxin
    Tang, Rong
    ORTHOPEDICS, 2012, 35 (05) : E647 - E653