EFFECTS OF UPSTREAM STEP GEOMETRY ON AXISYMMETRIC CONVERGING VANE ENDWALL SECONDARY FLOW AND HEAT TRANSFER AT TRANSONIC CONDITIONS

被引:0
|
作者
Li, Zhigang [1 ]
Liu, Luxuan [1 ]
Li, Jun [1 ]
Sibold, Ridge A. [2 ]
Ng, Wing F. [2 ]
Xu, Hongzhou [3 ]
Fox, Michael [3 ]
机构
[1] Xi An Jiao Tong Univ, Inst Turbomachinery, Xian 710049, Peoples R China
[2] Virginia Polytech Inst & State Univ, Dept Mech Engn, Blacksburg, VA 24061 USA
[3] Solar Turbines Inc, San Diego, CA USA
关键词
TURBINE BLADE; FREESTREAM TURBULENCE; SCALE; CASCADE;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a detailed experimental and numerical study on the effects of upstream step geometry on the endwall secondary flow and heat transfer in a transonic linear turbine vane passage with axisymmetric converging endwalls. The upstream step geometry represents the misalignment between the combustor exit and the nozzle guide vane endwall. The experimental measurements were performed in a blowdown wind tunnel with an exit Mach number of 0.85 and an exit Re of 1.5 x 10(6). A high freestream turbulence level of 16% was set at the inlet, which represents the typical turbulence conditions in a gas turbine engine. Two upstream step geometries were tested for the same vane profile: a baseline configuration with a gap located 0.88Cx (43.8 mm) upstream of the vane leading edge (upstream step height = 0 mm) and a misaligned configuration with a backward facing step located just before the gap at 0.88Cx (43.8 mm) upstream of the vane leading edge (step height = 4.45% span). The endwall temperature history was measured using transient infrared thermography, from which the endwall thermal load distribution, namely Nusselt number, were derived. This paper also presents a comparison with CFD predictions performed by solving the steady-state Reynolds Averaged Navier Stokes (RANS) with Reynolds Stress Model using the commercial CFD solver ANSYS Fluent v.15. The CFD simulations were conducted at a range of different upstream step geometries: three forward-facing (upstream step geometries with step heights from - 5.25 to 0% span), and five backward-facing, upstream step geometries (step heights from 0 to 6.56% span). These CFD results were used to highlight the link between heat transfer patterns and the secondary flow structures, and explain the effects of upstream step geometry. Experimental and numerical results indicate that the backward-facing upstream step geometry will significantly enlarge the high thermal load region and result in an obvious increase (up to 140%) in the heat transfer coefficient level, especially for arched regions around the vane leading edge. However, the forward-facing upstream geometry will modestly shrink the high thermal load region and reduce the heat transfer coefficient (by similar to 10%-40% decrease), especially for the suction side regions near the vane leading edge. The aerodynamic loss appears to have a slight increase (0.3% - 1.3%) as a result of the forward-facing upstream step geometry, but is slightly reduced (by 0.1% - 0.3%) by the presence of the backward upstream step geometry.
引用
收藏
页码:701 / 716
页数:16
相关论文
共 50 条
  • [21] Measurement of heat/mass transfer at second stage vane endwall according to step heights
    Kim, JeongJu
    Sohn, Ho-Seong
    Park, Hee Seung
    Hsu, Wei-Ting
    Ueda, Osamnu
    Cho, Hyung Hee
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2021, 35 (10) : 4575 - 4583
  • [22] Experimental Study of the Endwall Heat Transfer of a Transonic Nozzle Guide Vane With Upstream Jet Purge Cooling Part 1-Effect of Density Ratio
    Mao, Shuo
    Sibold, Ridge
    Ng, Wing F.
    Li, Zhigang
    Bai, Bo
    Xu, Hongzhou
    Fox, Michael
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2022, 144 (05):
  • [23] Measurement of heat/mass transfer at second stage vane endwall according to step heights
    JeongJu Kim
    Ho-Seong Sohn
    Hee Seung Park
    Wei-Ting Hsu
    Osamnu Ueda
    Hyung Hee Cho
    Journal of Mechanical Science and Technology, 2021, 35 : 4575 - 4583
  • [24] Measurements and modeling of the flow and heat transfer in a contoured vane-endwall passage
    Pasinato, HD
    Squires, KD
    Roy, RP
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (26) : 5685 - 5702
  • [25] A converging slot-hole film-cooling geometry - Part 2: Transonic nozzle guide vane heat transfer and loss
    Sargison, JE
    Guo, SM
    Oldfield, MLG
    Lock, GD
    Rawlinson, AJ
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2002, 124 (03): : 461 - 471
  • [26] Experimental Study of the Endwall Heat Transfer of a Transonic Nozzle Guide Vane With Upstream Jet Purge Cooling Part 2-Effect of Combustor-Nozzle Guide Vane Misalignment
    Mao, Shuo
    Sibold, Ridge
    Ng, Wing F.
    Li, Zhigang
    Bai, Bo
    Xu, Hongzhou
    Fox, Michael
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2022, 144 (05):
  • [27] Effects of an Upstream Cavity on the Secondary Flow in a Transonic Turbine Cascade
    El Ella, H. M. Abo
    Sjolander, S. A.
    Praisner, T. J.
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2012, 134 (05):
  • [28] EFFECTS OF AN UPSTREAM CAVITY ON THE SECONDARY FLOW IN A TRANSONIC TURBINE CASCADE
    El Ella, H. M. Abo
    Sjolander, S. A.
    Praisner, T. J.
    PROCEEDINGS OF THE ASME TURBO EXPO 2010: TURBOMACHINERY: AXIAL FLOW FAN AND COMPRESSOR AERODYNAMICS DESIGN METHODS, AND CFD MODELING FOR TURBOMACHINERY, VOL 7, PTS A-C, 2010, : 1413 - 1424
  • [29] Heat Transfer Performance of a Transonic Turbine Blade Passage in the Presence of Leakage Flow Through Upstream Slot and Mateface Gap With Endwall Contouring
    Roy, Arnab
    Jain, Sakshi
    Ekkad, Srinath V.
    Ng, Wing
    Lohaus, Andrew S.
    Crawford, Michael E.
    Abraham, Santosh
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2017, 139 (12):
  • [30] Unsteady Effects of Upstream Nozzle Wakes on Hub-Endwall Flow and Heat Transfer of an HPT Rotor
    Chen, L.
    Lu, Z. F.
    Dai, R.
    JOURNAL OF APPLIED FLUID MECHANICS, 2020, 13 (02) : 513 - 526