Continuous-flow synthesis of [11C]raclopride, a positron emission tomography radiotracer, on a microfluidic chip

被引:13
|
作者
Haroun, Samar [1 ]
Sanei, Zahra [1 ]
Jivan, Salma [2 ]
Schaffer, Paul [1 ,2 ]
Ruth, Thomas J. [1 ,2 ]
Li, Paul C. H. [1 ]
机构
[1] Simon Fraser Univ, Dept Chem, Burnaby, BC V5A 1S6, Canada
[2] TRIUMF, Div Nucl Med, Vancouver, BC V6T 2A3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
microfluidic reactor; positron emission tomography (PET) imaging; radiotracer; raclopride; polydimethylsiloxane (PDMS) chip; MICRO REACTORS; PET; BINDING; MICROREACTORS; MICROMIXERS; TECHNOLOGY; PRINCIPLES; RECEPTORS; BRAIN;
D O I
10.1139/cjc-2012-0331
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
C-11-labelled radiotracers such as [C-11]raclopride are produced in a process that can take between 45 and 60 min to complete. These conventional approaches can consume upwards of 75% of the C-11 (t(1/2) = 20 min) due to radioactive decay alone, even more if synthesis losses are considered. To compensate, a large starting quantity of radioactive precursors such as [C-11]methyl iodide is required to produce an adequate amount of the tracer for injection. In this investigation, a continuous-flow microchip is explored for the purpose of synthesizing C-11 radiotracers in a shorter time by exploiting the favorable reaction kinetics of using smaller reaction volumes. To enhance the mixing of reagents within the microchannel, a micromixer "loop" design was used in fabricating various polydimethylsiloxane chip styles. With a loop design implemented in an abacus-style chip for the production of nonradioactive raclopride, shorter reaction times, reduced precursor use, and improved yields were possible when compared with the use of a simple serpentine design (no loop-style chip). However, when performing the equivalent radiochemical reaction, the results were not as favorable. Using the loop design in a full loop-style chip, parameters such as premixing the reagents, reducing flow rate, and varying reagent concentrations were explored to improve the yields of [C-11]raclopride (in terms of relative radioactivity) formed. The full loop chip design produced the best results, and future work will see the polydimethylsiloxane prototype chip design translated into a glass chip for further optimization.
引用
收藏
页码:326 / 332
页数:7
相关论文
共 50 条
  • [41] AN ASYMMETRIC APPROACH TO THE RADIOSYNTHESIS OF BOTH ENANTIOMERS OF α-[11C]METHYLDOPA AND α-[11C]METHYLTYROSINE FOR POSITRON EMISSION TOMOGRAPHY
    Popkov, A.
    Nadvornik, M.
    Jirman, J.
    Kruzberska, P.
    Lycka, A.
    Weidlich, T.
    Kozisek, J.
    Breza, M.
    Lehel, S.
    Gillings, N. M.
    [J]. CZECHOSLOVAK JOURNAL OF PHYSICS, 2006, 56 : D689 - D693
  • [42] Microfluidic chip synthesizes radiolabel for positron emission tomography
    Wilson, M
    [J]. PHYSICS TODAY, 2006, 59 (03) : 19 - 19
  • [43] Effect of repetitive transcranial magnetic stimulation in Parkinson's disease: analysis of dopamine release by [11C]-raclopride positron emission tomography
    Kim, J.
    Lee, W.
    Chung, E.
    Choi, Y.
    Lee, G.
    Kim, B.
    [J]. MOVEMENT DISORDERS, 2006, 21 : S583 - S583
  • [44] Abused drugs and natural rewards target different regions of the dopamine system in humans:: Positron emission tomography studies with [11C]raclopride
    Dagher, A
    Boileau, I
    Small, D
    Asaad, JM
    Pihl, R
    Benkelfat, C
    [J]. ANNALS OF NEUROLOGY, 2002, 52 (03) : S45 - S46
  • [45] Amphetamine-induced dopamine release in rat: Whole-brain spatiotemporal analysis with [11C]raclopride and positron emission tomography
    Johansson, Jarkko
    Ericsson, Madelene
    Axelsson, Jan
    af Bjerken, Sara
    Virel, Ana
    Karalija, Nina
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2024, 44 (03): : 434 - 445
  • [46] Optimization of [11C] Raclopride Positron Emission Tomographic Rat Studies: Comparison of Methods for Image Quantification
    Torrent, Elia
    Farre, Magi
    Abasolo, Ibane
    Millan, Olga
    Llop, Jordi
    Domingo Gispert, Juan
    Ruiz, Alba
    Pareto, Deborah
    [J]. MOLECULAR IMAGING, 2013, 12 (04): : 257 - 262
  • [47] An alternative synthesis of [11C]raclopride for routine use
    Kiichi Ishiwata
    Shin-ichi Ishii
    Michio Senda
    [J]. Annals of Nuclear Medicine, 1999, 13 : 195 - 197
  • [48] An alternative synthesis of [11C]raclopride for routine use
    Ishiwata, K
    Ishii, S
    Senda, M
    [J]. ANNALS OF NUCLEAR MEDICINE, 1999, 13 (03) : 195 - 197
  • [49] Characterization of hepatic tumors using [11C]metomidate through positron emission tomography: comparison with [11C]acetate
    Roivainen, Anne
    Naum, Alexandru
    Nuutinen, Heikki
    Leino, Rauli
    Nurmi, Heimo
    Nagren, Kjell
    Parkkola, Riitta
    Virtanen, Johanna
    Kallajoki, Markku
    Kujari, Harry
    Ovaska, Jari
    Roberts, Peter
    Seppanen, Marko
    [J]. EJNMMI RESEARCH, 2013, 3 : 1 - 7
  • [50] Imaging the serotonin transporter with positron emission tomography: initial human studies with [11C]DAPP and [11C]DASB
    S. Houle
    N. Ginovart
    D. Hussey
    J.H. Meyer
    A.A. Wilson
    [J]. European Journal of Nuclear Medicine, 2000, 27 : 1719 - 1722