Spectroscopic method to study low charge state ion and cold electron population in ECRIS plasma

被引:19
|
作者
Kronholm, R. [1 ]
Kalvas, T. [1 ]
Koivisto, H. [1 ]
Tarvainen, O. [1 ]
机构
[1] Univ Jyvaskyla, Dept Phys, Jyvaskyla, Finland
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 04期
基金
芬兰科学院;
关键词
CYCLOTRON-RESONANCE PLASMAS; CROSS-SECTIONS;
D O I
10.1063/1.5023434
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The results of optical emission spectroscopy experiments probing the cold electron population of a 14 GHz Electron Cyclotron Resonance Ion Source (ECRIS) are reported. The study has been conducted with a high resolution spectrometer and data acquisition setup developed specifically for the diagnostics of weak emission line characteristic to ECRIS plasmas. The optical emission lines of low charge state ions and neutral atoms of neon have been measured and analyzed with the line-ratio method. The aforementioned electron population temperature of the cold electron population (T-e < 100 eV) is determined for Maxwell-Boltzmann and Druyvesteyn energy distributions to demonstrate the applicability of the method. The temperature was found to change significantly when the extraction voltage of the ion source is turned on/off. In the case of the Maxwellian distribution, the temperature of the cold electron population is 20 +/- 10 eV when the extraction voltage is off and 40 +/- 10 eV when it is on. The optical emission measurements revealed that the extraction voltage also affects both neutral and ion densities. Based on the rate coefficient analysis with the aforementioned temperatures, switching the extraction voltage off decreases the rate coefficient of neutral to 1+ ionization to 42% and 1+ to 2+ ionization to 24% of the original. This suggests that switching the extraction voltage on favors ionization to charge states >= 2+ and, thus, the charge state distributions of ECRIS plasmas are probably different with the extraction voltage on/off. It is therefore concluded that diagnostics results of ECRIS plasmas obtained without the extraction voltage are not depicting the plasma conditions in normal ECRIS operation. Published by AIP Publishing.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Dust particle charge in plasma with ion flow and electron depletion near plasma boundaries
    Douglass, Angela
    Land, Victor
    Matthews, Lorin
    Hyde, Truell
    PHYSICS OF PLASMAS, 2011, 18 (08)
  • [42] Exact Thresholds in the Dynamics of Cold Plasma with Electron-Ion Collisions
    Rozanova, O.
    Chizhonkov, E.
    Delova, M.
    APPLICATION OF MATHEMATICS IN TECHNICAL AND NATURAL SCIENCES (AMITANS 2020), 2020, 2302
  • [43] Dusty plasma diagnostics methods for charge, electron temperature, and ion density
    Liu, Bin
    Goree, J.
    Fortov, V. E.
    Lipaev, A. M.
    Molotkov, V. I.
    Petrov, O. F.
    Morfill, G. E.
    Thomas, H. M.
    Ivlev, A. V.
    PHYSICS OF PLASMAS, 2010, 17 (05)
  • [44] EVOLUTION OF ION-CHARGE-STATE DISTRIBUTIONS IN AN ELECTRON-BEAM ION TRAP
    PENETRANTE, BM
    BARDSLEY, JN
    DEWITT, D
    CLARK, M
    SCHNEIDER, D
    PHYSICAL REVIEW A, 1991, 43 (09): : 4861 - 4872
  • [45] Letter: New fragment ion production method using super cold electrons in electron cyclotron resonance plasma
    Kidera, Masanori
    Takahashi, Kazuya
    Enomoto, Shuichi
    Goto, Akira
    Yano, Yasushige
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2007, 13 (05) : 355 - 358
  • [46] Ion and electron sheath characteristics in a low density and low temperature plasma
    Borgohain, Binita
    Bailung, H.
    PHYSICS OF PLASMAS, 2017, 24 (11)
  • [47] EFFICIENCY MEASUREMENTS FOR A LOW CHARGE-STATE IONIC INJECTION INTO AN ELECTRON-BEAM ION-SOURCE
    VISENTIN, B
    VANDUPPEN, P
    LEROY, PA
    HARRAULT, F
    GOBIN, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 101 (03): : 275 - 279
  • [48] Model for Calculation of Ion Charge-State Distribution in ECR ion source plasma
    Philippov, Alexandr V.
    Shirkov, Grigori D.
    Consoli, Fabrizio
    Gammino, Santo
    Ciavola, Giovanni
    Celona, Luigi
    Barbarino, Sebastiano
    EIGTH SEMINAR ON PROBLEMS OF THEORETICAL AND APPLIED ELECTRON AND ION OPTICS, 2008, 7121
  • [49] Development of a cold target recoil ion momentum spectrometer and a projectile charge state analyzer setup to study electron transfer processes in highly charged ion-atom/molecule collisions
    Siddiki, Md Abul Kalam Azad
    Nrishimhamurty, M.
    Kumar, Kamal
    Mukherjee, Jibak
    Tribedi, Lokesh. C.
    Khan, Arnab
    Misra, Deepankar
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (11):