First experience with single-source dual-energy computed tomography in six patients with acute arthralgia: a feasibility experiment using joint aspiration as a reference

被引:20
|
作者
Diekhoff, Torsten [1 ]
Ziegeler, Katharina [2 ]
Feist, Eugen [2 ]
Kiefer, Tobias [1 ]
Mews, Jurgen [3 ]
Hamm, Bernd [1 ]
Hermann, Kay-Geert A. [1 ]
机构
[1] Free Univ Berlin, Humboldt Univ, Charite Univ Med, Dept Radiol, D-10117 Berlin, Germany
[2] Free Univ Berlin, Humboldt Univ, Charite Univ Med, Dept Rheumatol & Clin Immunol, D-10117 Berlin, Germany
[3] Toshiba Med Syst Europe, NL-2701 RP Zoetermeer, Netherlands
关键词
Dual energy; Gout; Single source; CLINICAL UTILITY; GOUT; CT; DIAGNOSIS; HYPERURICEMIA; DEPOSITION; ULTRASOUND; DECT;
D O I
10.1007/s00256-015-2204-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Dual-energy computed tomography (DECT) is an emerging imaging technique for examining patients with suspected gout. Single-source dual-energy CT (S-DECT) is a new way of obtaining DECT information on conventional CT scanners rather than using special dual-source CT systems. We tested the feasibility of S-DECT (320-row CT; Aquilion ONE, Toshiba Medical Systems, Otawara, Japan) in 6 patients (5 men, 1 woman; mean age 61.3, range 48 to 69 years) with acute arthralgia and suspected gout, and compared the S-DECT findings with the results of joint aspiration. Three patients had a diagnosis of gouty arthritis with negatively birefringent crystals in synovial fluid, in addition to gouty tophi in S-DECT. Three patients had no detectable crystals by polarization microscopy and no tophi on DECT. Their final diagnoses were rheumatoid arthritis, activated osteoarthritis, and septic arthritis in one case each. This initial experience suggests that S-DECT might be a valuable alternative to dual-source CT. Hence, more patients may benefit from its additional diagnostic abilities in the future.
引用
收藏
页码:1573 / 1577
页数:5
相关论文
共 50 条
  • [31] Single-source dual-energy computed tomography for the assessment of bone marrow oedema in vertebral compression fractures: a prospective diagnostic accuracy study
    Torsten Diekhoff
    Nils Engelhard
    Michael Fuchs
    Matthias Pumberger
    Michael Putzier
    Jürgen Mews
    Marcus Makowski
    Bernd Hamm
    Kay-Geert A. Hermann
    European Radiology, 2019, 29 : 31 - 39
  • [32] Single-source dual-energy computed tomography for the assessment of bone marrow oedema in vertebral compression fractures: a prospective diagnostic accuracy study
    Diekhoff, Torsten
    Engelhard, Nils
    Fuchs, Michael
    Pumberger, Matthias
    Putzier, Michael
    Mews, Jurgen
    Makowski, Marcus
    Hamm, Bernd
    Hermann, Kay-Geert A.
    EUROPEAN RADIOLOGY, 2019, 29 (01) : 31 - 39
  • [33] Urinary stone differentiation in patients with large body size using dual-energy dual-source computed tomography
    Qu, Mingliang
    Jaramillo-Alvarez, Giselle
    Ramirez-Giraldo, Juan C.
    Liu, Yu
    Duan, Xinhui
    Wang, Jia
    Vrtiska, Terri J.
    Krambeck, Amy E.
    Lieske, John
    McCollough, Cynthia H.
    EUROPEAN RADIOLOGY, 2013, 23 (05) : 1408 - 1414
  • [34] Urinary stone differentiation in patients with large body size using dual-energy dual-source computed tomography
    Mingliang Qu
    Giselle Jaramillo-Alvarez
    Juan C. Ramirez-Giraldo
    Yu Liu
    Xinhui Duan
    Jia Wang
    Terri J. Vrtiska
    Amy E. Krambeck
    John Lieske
    Cynthia H. McCollough
    European Radiology, 2013, 23 : 1408 - 1414
  • [35] Clinical feasibility of 4D single-source dual-energy CT for proton therapy of lung-cancer patients
    Wohlfahrt, P.
    Hofmann, C.
    Troost, E. G. C.
    Richter, C.
    Jakobi, A.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1148 - S1148
  • [36] Diagnostic accuracy of single-source dual-energy computed tomography and ultrasonography for detection of lateral cervical lymph node metastases of papillary thyroid carcinoma
    Li, Lin
    Cheng, Sai-Nan
    Zhao, Yan-Feng
    Wang, Xiao-Yi
    Luo, De-Hong
    Wang, Yong
    JOURNAL OF THORACIC DISEASE, 2019, 11 (12) : 5032 - 5041
  • [37] Combination of single-source dual-energy computed tomography (CT) parameters and extracellular volume fraction for predicting lymphovascular and perineural invasion in colorectal cancer
    Zhang, Yuting
    Wen, Yurong
    Li, Shenglin
    Deng, Liangna
    Han, Tao
    Jing, Mengyuan
    Zhao, Jianhong
    Zhou, Junlin
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (10) : 7524 - 7539
  • [38] IDENTIFYING URIC ACID STONES USING DUAL-ENERGY COMPUTED TOMOGRAPHY: FIRST DIAGNOSTIC PERFORMANCE EVALUATION IN PATIENTS
    Kozomara, M.
    Stolzmann, P.
    Scheffel, H.
    Leschaka, S.
    Muentener, M.
    JOURNAL OF ENDOUROLOGY, 2009, 23 : A246 - A246
  • [39] Material Density Hepatic Steatosis Quantification on Intravenous Contrast-Enhanced Rapid Kilovolt (Peak)-Switching Single-Source Dual-Energy Computed Tomography
    Patel, Bhavik N.
    Kumbla, Rekha Anjali
    Berland, Lincoln L.
    Fineberg, Naomi S.
    Morgan, Desiree E.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (06) : 904 - 910
  • [40] Osteitis: a retrospective feasibility study comparing single-source dual-energy CT to MRI in selected patients with suspected acute gout (vol 46, pg 185, 2017)
    Diekhoff, Torsten
    Scheel, Michael
    Hermann, Sandra
    Mews, Juergen
    Hamm, Bernd
    Hermann, Kay Geert A.
    SKELETAL RADIOLOGY, 2018, 47 (12) : 1719 - 1719