First experience with single-source dual-energy computed tomography in six patients with acute arthralgia: a feasibility experiment using joint aspiration as a reference

被引:20
|
作者
Diekhoff, Torsten [1 ]
Ziegeler, Katharina [2 ]
Feist, Eugen [2 ]
Kiefer, Tobias [1 ]
Mews, Jurgen [3 ]
Hamm, Bernd [1 ]
Hermann, Kay-Geert A. [1 ]
机构
[1] Free Univ Berlin, Humboldt Univ, Charite Univ Med, Dept Radiol, D-10117 Berlin, Germany
[2] Free Univ Berlin, Humboldt Univ, Charite Univ Med, Dept Rheumatol & Clin Immunol, D-10117 Berlin, Germany
[3] Toshiba Med Syst Europe, NL-2701 RP Zoetermeer, Netherlands
关键词
Dual energy; Gout; Single source; CLINICAL UTILITY; GOUT; CT; DIAGNOSIS; HYPERURICEMIA; DEPOSITION; ULTRASOUND; DECT;
D O I
10.1007/s00256-015-2204-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Dual-energy computed tomography (DECT) is an emerging imaging technique for examining patients with suspected gout. Single-source dual-energy CT (S-DECT) is a new way of obtaining DECT information on conventional CT scanners rather than using special dual-source CT systems. We tested the feasibility of S-DECT (320-row CT; Aquilion ONE, Toshiba Medical Systems, Otawara, Japan) in 6 patients (5 men, 1 woman; mean age 61.3, range 48 to 69 years) with acute arthralgia and suspected gout, and compared the S-DECT findings with the results of joint aspiration. Three patients had a diagnosis of gouty arthritis with negatively birefringent crystals in synovial fluid, in addition to gouty tophi in S-DECT. Three patients had no detectable crystals by polarization microscopy and no tophi on DECT. Their final diagnoses were rheumatoid arthritis, activated osteoarthritis, and septic arthritis in one case each. This initial experience suggests that S-DECT might be a valuable alternative to dual-source CT. Hence, more patients may benefit from its additional diagnostic abilities in the future.
引用
收藏
页码:1573 / 1577
页数:5
相关论文
共 50 条
  • [1] First experience with single-source dual-energy computed tomography in six patients with acute arthralgia: a feasibility experiment using joint aspiration as a reference
    Torsten Diekhoff
    Katharina Ziegeler
    Eugen Feist
    Tobias Kiefer
    Jürgen Mews
    Bernd Hamm
    Kay-Geert A Hermann
    Skeletal Radiology, 2015, 44 : 1573 - 1577
  • [2] Determination of Renal Stone Composition in Phantom and Patients Using Single-Source Dual-Energy Computed Tomography
    Kulkarni, Naveen M.
    Eisner, Brian H.
    Pinho, Daniella F.
    Joshi, Mukta C.
    Kambadakone, Avinash R.
    Sahani, Dushyant V.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (01) : 37 - 45
  • [3] Feasibility of Single-Source Dual-Energy Computed Tomography for Urinary Stone Characterization and Value of Iterative Reconstructions
    Morsbach, Fabian
    Wurnig, Moritz C.
    Mueller, Daniel
    Krauss, Bernhard
    Korporaal, Johannes Georg
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2014, 49 (03) : 125 - 130
  • [4] Material differentiation in forensic radiology with single-source dual-energy computed tomography
    Thomas D. Ruder
    Yannick Thali
    Stephan A. Bolliger
    Sandra Somaini-Mathier
    Michael J. Thali
    Gary M. Hatch
    Sebastian T. Schindera
    Forensic Science, Medicine, and Pathology, 2013, 9 : 163 - 169
  • [5] Optimal window settings in single-source dual-energy computed tomography of the abdomen
    Noda, Yoshifumi
    Goshima, Satoshi
    Kozaka, Kazuto
    Yoneda, Norihide
    Mizuno, Nozomi
    Kato, Akiko
    Fujimoto, Keita
    Tsuji, Yusuke
    Miyoshi, Toshiharu
    Kawada, Hiroshi
    Kawai, Nobuyuki
    Tanahashi, Yukichi
    Matsuo, Masayuki
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 109 : 204 - 209
  • [6] Material differentiation in forensic radiology with single-source dual-energy computed tomography
    Ruder, Thomas D.
    Thali, Yannick
    Bolliger, Stephan A.
    Somaini-Mathier, Sandra
    Thali, Michael J.
    Hatch, Gary M.
    Schindera, Sebastian T.
    FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2013, 9 (02) : 163 - 169
  • [7] Quantification of Iodine Concentration Using Single-Source Dual-Energy Computed Tomography in a Calf Liver
    Agostini, Andrea
    Mahmood, Usman
    Erdi, Yusuf
    Borgheresi, Alessandra
    Ragucci, Monica
    Sawan, Peter
    Ryan, Davinia
    Laino, Maria Elena
    Corrias, Giuseppe
    Mannelli, Lorenzo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (02) : 222 - 229
  • [9] First experience with single-source, dual-energy CCTA for monochromatic stent imaging
    Stehli, Julia
    Fuchs, Tobias A.
    Singer, Adrian
    Bull, Sacha
    Clerc, Olivier F.
    Possner, Mathias
    Gaemperli, Oliver
    Buechel, Ronny R.
    Kaufmann, Philipp A.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (05) : 507 - 512
  • [10] Measurement of Myocardial Extracellular Volume Fraction FromIodine Density Images Using Single-Source, Dual-Energy Computed Tomography: A Feasibility Study
    Ohta, Yasutoshi
    Kitao, Shinichiro
    Watanabe, Tomomi
    Mukai, Natsuko
    Kishimoto, Junichi
    Yamamoto, Kazuhiro
    Ogawa, Toshihide
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (05) : 750 - 756