The purpose of our study was to evaluate the accuracy of MR myelography in depicting disc herniation in the lumbar spine when compared with conventional MRI in patients presenting with clinical evidence of disc herniation. One hundred patients re for conventional MR imaging of the lumbar spine also had coronal MR (TR 9000 ms, TE 272 ms eff, NEX 3, echo train length 32) myelography performed. Three experienced observers compared magnetic resonance myelography (MRM) with conventional lumbar spine MR using the following variables: visibility of thecal sac and nerve roots, and the presence, location and severity of disc herniation. Disc protrusions were seen at 110 disc space levels on conventional MR images as apposed to 93 on MRM. However, only 72% of lesions seen on conventional MR were diagnosed by MRM. Similarly only 63.8% of nerve root compression abnormalities seen at:conventional MR were visualized when compared with conventional MRM. The sensitivity, specificity and accuracy of MRM when compared with conventional MR was 72, 93 and 85%. respectively. The MRM technique yields images that resemble conventional myelography and may be used to help confirm abnormalities seen on conventional MR in selected cases; however,the large number of false-positive and false-negative examinations indicates-that caution should be used in interpreting MRM images.
机构:
Univ Fed Rio de Janeiro, Dept Radiol, Sch Med, Rio De Janeiro, Brazil
Clin Diagnost Imagem CDPI, Rio De Janeiro, BrazilUniv Fed Rio de Janeiro, Dept Radiol, Sch Med, Rio De Janeiro, Brazil
Kinder, Andre
Palma Filho, Fernando
论文数: 0引用数: 0
h-index: 0
机构:
Clin Diagnost Imagem CDPI, Rio De Janeiro, BrazilUniv Fed Rio de Janeiro, Dept Radiol, Sch Med, Rio De Janeiro, Brazil
Palma Filho, Fernando
Ribeiro, Elisio
论文数: 0引用数: 0
h-index: 0
机构:
Clin Diagnost Imagem CDPI, Rio De Janeiro, BrazilUniv Fed Rio de Janeiro, Dept Radiol, Sch Med, Rio De Janeiro, Brazil
Ribeiro, Elisio
Domingues, Romeu C.
论文数: 0引用数: 0
h-index: 0
机构:
Clin Diagnost Imagem CDPI, Rio De Janeiro, BrazilUniv Fed Rio de Janeiro, Dept Radiol, Sch Med, Rio De Janeiro, Brazil
Domingues, Romeu C.
Domingues, Roberto C.
论文数: 0引用数: 0
h-index: 0
机构:
Clin Diagnost Imagem CDPI, Rio De Janeiro, BrazilUniv Fed Rio de Janeiro, Dept Radiol, Sch Med, Rio De Janeiro, Brazil
Domingues, Roberto C.
Marchiori, Edson
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Rio de Janeiro, Dept Radiol, Sch Med, Rio De Janeiro, BrazilUniv Fed Rio de Janeiro, Dept Radiol, Sch Med, Rio De Janeiro, Brazil
Marchiori, Edson
Gasparetto, Emerson
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Rio de Janeiro, Dept Radiol, Sch Med, Rio De Janeiro, Brazil
Clin Diagnost Imagem CDPI, Rio De Janeiro, BrazilUniv Fed Rio de Janeiro, Dept Radiol, Sch Med, Rio De Janeiro, Brazil