Newtonian and non-Newtonian blood flow in coiled cerebral aneurysms

被引:77
|
作者
Morales, Hernan G. [1 ,2 ]
Larrabide, Ignacio [1 ,2 ,4 ,5 ]
Geers, Arjan J. [1 ,2 ]
Aguilar, Martha L. [1 ,2 ]
Frangi, Alejandro F. [1 ,2 ,3 ]
机构
[1] Univ Pompeu Fabra, Ctr Computat Imaging & Simulat Technol Biomed CIS, Barcelona, Spain
[2] Networking Res Ctr Bioengn Biomat & Nanomed CIBER, Madrid, Spain
[3] Univ Sheffield, Dept Mech Engn, Ctr Computat Imaging & Simulat Technol Biomed CIS, Sheffield, S Yorkshire, England
[4] PLADEMA CONICET, Tandil, Argentina
[5] Univ Nacl Ctr, Tandil, Argentina
关键词
Cerebral aneurysms; Endovascular coiling; Hemodynamics; CFD; Non-Newtonian fluid flow; GUGLIELMI DETACHABLE COILS; INTRACRANIAL ANEURYSMS; SACCULAR ANEURYSM; HEMODYNAMICS; MODEL; SIMULATION; EMBOLIZATION; DYNAMICS; ARTERIES; REGIONS;
D O I
10.1016/j.jbiomech.2013.06.034
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Endovascular coiling aims to isolate the aneurysm from blood circulation by altering hemodynamics inside the aneurysm and triggering blood coagulation. Computational fluid dynamics (CFD) techniques have the potential to predict the post-operative hemodynamics and to investigate the complex interaction between blood flow and coils. The purpose of this work is to study the influence of blood viscosity on hemodynamics in coiled aneurysms. Three image-based aneurysm models were used. Each case was virtually coiled with a packing density of around 30%. CFD simulations were performed in coiled and untreated aneurysm geometries using a Newtonian and a Non-Newtonian fluid models. Newtonian fluid slightly overestimates the intra-aneurysmal velocity inside the aneurysm before and after coiling. There were numerical differences between fluid models on velocity magnitudes in coiled simulations. Moreover, the non-Newtonian fluid model produces high viscosity (>0.007 [Pa s]) at aneurysm fundus after coiling. Nonetheless, these local differences and high-viscous regions were not sufficient to alter the main flow patterns and velocity magnitudes before and after coiling. To evaluate the influence of coiling on intra-aneurysmal hemodynamics, the assumption of a Newtonian fluid can be used. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2158 / 2164
页数:7
相关论文
共 50 条
  • [21] Non-Newtonian Effect on Hemodynamic Characteristics of Blood Flow in Stented Cerebral Aneurysm
    Huang, Changsheng
    Chai, Zhenhua
    Shi, Baochang
    [J]. COMMUNICATIONS IN COMPUTATIONAL PHYSICS, 2013, 13 (03) : 916 - 928
  • [22] Non-Newtonian laminar flow and heat transfer in helically coiled pipes
    Ogulu, A.
    Bawo, D.D.S.
    [J]. Modelling, Measurement and Control B, 2002, 71 (5-6): : 41 - 49
  • [23] NON-NEWTONIAN FLOW PAST A SWARM OF NEWTONIAN DROPLETS
    ZHU, JT
    DENG, Q
    [J]. CHEMICAL ENGINEERING SCIENCE, 1994, 49 (01) : 147 - 150
  • [24] FLOW OF NON-NEWTONIAN FLUID
    THIRIET, M
    MARTINBORRET, G
    HECHT, F
    [J]. ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 1995, 103 (03) : C151 - C151
  • [25] AN EQUATION FOR NON-NEWTONIAN FLOW
    SHANGRAW, R
    GRIM, W
    MATTOCKS, AM
    [J]. TRANSACTIONS OF THE SOCIETY OF RHEOLOGY, 1961, 5 : 247 - 260
  • [26] Flow of a non-Newtonian fluid
    V. G. Pridanov
    V. I. Khonichev
    [J]. Technical Physics, 2012, 57 : 1475 - 1478
  • [27] ON NON-NEWTONIAN EFFECTS IN CEREBRAL ANEURYSMS: A COMPUTATIONAL STUDY ON 12 PATIENT SPECIFIC ANEURYSMS
    Evju, Oyvind
    Mardal, Kent-Andre
    Valen-Sendstad, Kristian
    [J]. PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 841 - 842
  • [28] Theoretical analysis of non-Newtonian blood flow in a microchannel
    Tanveer, Anum
    Salahuddin, T.
    Khan, Mair
    Malik, M. Y.
    Alqarni, M. S.
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 191
  • [29] Flow of non-Newtonian fluids
    Avram, Marius Andrei
    Avram, Marioara
    Iliescu, Ciprian
    Bragaru, Adina
    [J]. 2006 INTERNATIONAL SEMICONDUCTOR CONFERENCE, VOLS 1 AND 2, 2007, : 463 - +
  • [30] INSTABILITY IN NON-NEWTONIAN FLOW
    PEARSON, JRA
    [J]. ANNUAL REVIEW OF FLUID MECHANICS, 1976, 8 : 163 - 181