摘要
Bone drilling is widely used in orthopedics and dental surgery; it is a technically surgical procedure. Recent technological improvements in this area are focused on efforts to reduce forces in bone drilling. The aim of this study was to compare changes in cutting force during dental bone drilling at various drilling conditions and drill tool geometry. In the present in vitro study, dog jaw bone with uniform thickness of cortical bone was used. Cutting force changes were measured during drilling process. Drill jig was designed and manufactured to fix jaw workpiece and mounted on the tool dynamometer to measure cutting force in drilling process. The dental implant drilling tests were conducted at various cutting speeds and feed rates. In this study drilling thrust force was observed 1.5 similar to 3.6[N] for MS type implant drilling and 3.1 similar to 4.9[N] for conventional high speed steel drilling, respectively. This further research will provide a basic quantitative approach for the timely issue of wide application of implant drilling in dental and orthopedic surgery fields.
引用
收藏
页码:2542 / +
页数:2
相关论文
共 50 条
  • [41] Performance of a new implant system and drilling protocol-A minipig intraoral dental implant model study
    Musskopf, Marta Liliana
    Stadler, Amanda Finger
    Fiorini, Tiago
    Ramos, Umberto Demoner
    Rabelo, Mariana de Sousa
    Pinto, Rodrigo Nahas de Castro
    Susin, Cristiano
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, : 40 - 51
  • [42] Oblique Cutting Based Mechanical Model for Insertion Torque of Dental Implant
    Li, Luli
    Zhang, Song
    Li, Quhao
    Bian, Cuirong
    Zhang, Airong
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2022, 35 (01)
  • [43] Oblique Cutting Based Mechanical Model for Insertion Torque of Dental Implant
    Luli Li
    Song Zhang
    Quhao Li
    Cuirong Bian
    Airong Zhang
    Chinese Journal of Mechanical Engineering, 2022, 35 (03) : 106 - 119
  • [44] Oblique Cutting Based Mechanical Model for Insertion Torque of Dental Implant
    Luli Li
    Song Zhang
    Quhao Li
    Cuirong Bian
    Airong Zhang
    Chinese Journal of Mechanical Engineering, 2022, 35
  • [45] Simplified Drilling Technique Does Not Decrease Dental Implant Osseointegration: A Preliminary Report
    Jimbo, Ryo
    Giro, Gabriela
    Marin, Charles
    Granato, Rodrigo
    Suzuki, Marcelo
    Tovar, Nick
    Lilin, Thomas
    Janal, Malvin
    Coelho, Paulo G.
    JOURNAL OF PERIODONTOLOGY, 2013, 84 (11) : 1599 - 1605
  • [46] Effect of cooling methods on cutting temperature, cutting force and hole quality in drilling of three ferrous alloys
    Islam, M. N.
    Boswell, B.
    INTERNATIONAL CONFERENCE ON MECHANICAL AND MANUFACTURING ENGINEERING (ICME2018), 2019, 1150
  • [47] The Effect of Simplifying Dental Implant Drilling Sequence on Osseointegration: An Experimental Study in Dogs
    Giro, Gabriela
    Tovar, Nick
    Marin, Charles
    Bonfante, Estevam A.
    Jimbo, Ryo
    Suzuki, Marcelo
    Janal, Malvin N.
    Coelho, Paulo G.
    INTERNATIONAL JOURNAL OF BIOMATERIALS, 2013, 2013
  • [48] Management of bleeding during dental implant surgery using a novel implant with an abbreviated drilling protocol: A clinical report
    Babayan, Mikhail
    Bidra, Avinash S.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (03): : 206 - 211
  • [49] Effects of rotary ultrasonic bone drilling on cutting force and temperature in the human bones
    Singh, Ravinder Pal
    Pandey, Pulak Mohan
    Behera, Chittaranjan
    Mridha, Asit Ranjan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2020, 234 (08) : 829 - 842