The accuracy of the extramedullary and intramedullary femoral alignment system in total knee arthroplasty for varus osteoarthritic knee

被引:21
|
作者
Jung, Woon-hwa [1 ]
Chun, Chung-woo [1 ]
Lee, Ji-hoon [1 ]
Ha, Jae-hun [1 ]
Jeong, Jae-Heon [1 ]
机构
[1] Murup Hosp, Dept Orthopaed Surg, Changwon Si 631423, Gyeongnam, South Korea
关键词
Total knee arthroplasty; Extramedullary alignment; Intramedullary alignment; Tibiofemoral alignment; MECHANISMS; FAILURE;
D O I
10.1007/s00167-012-1994-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The intramedullary (IM) femoral alignment system does not alway guarantee accuracy of the component position in the total knee arthroplasty (TKA). In some cases, the extramedullary (EM) femoral alignment system in total knee arthroplasty (TKA) is a useful alternative surgical option to adjust femoral component alignment. In the EM technique, accuracy of the femoral head center location is mandatory. The purpose of this prospective randomized study was to compare the alignment after TKA using two different femoral alignment systems. From January 2009 to December 2009, 91 patients (106 knees) with osteoarthritis underwent TKA. The IM femoral alignment system was used in 50 TKAs, and the EM system was used in 56 TKAs. We measured the coronal, sagittal alignment of the femoral component, and overall alignment from full-length standing. Anteroposterior radiographs were taken 1 year after surgery. The overall limb alignment was 0.2A degrees A A +/- A 1.9A degrees A varus in the EM group and 1.1A degrees A A +/- A 1.9A degrees A valgus in the IM group (p = 0.001). The coronal alignment of the femoral component was 90.0A degrees A A +/- A 1.1A degrees in the EM group and 90.3A degrees A A +/- A 1.2A degrees in the IM group, not statistically different (n.s.). The sagittal alignment of the femoral component was 2.3A degrees A A +/- A 1.7A degrees in the EM group and 2.5A degrees A A +/- A 1.0A degrees in the IM group (n.s.). Clinically acceptable overall limb alignment was achieved in 91.1 % of EM group and 84.0 % of IM group (n.s.). The present study suggests that by applying our EM technique that uses a newly designed mechanical axis marker system, the alignment of the femoral component and overall limb alignment is reliable and at least as accurate as the standard IM technique. I.
引用
收藏
页码:629 / 635
页数:7
相关论文
共 50 条
  • [21] Intramedullary versus extramedullary alignment guides on total knee arthroplasty: a meta-analysis
    Qin, Ya-fei
    Li, Na
    Shi, Yong-xin
    Sun, Kai
    Li, Zhi-jun
    Li, Hui
    JOURNAL OF COMPARATIVE EFFECTIVENESS RESEARCH, 2018, 7 (12) : 1181 - 1193
  • [22] Unusual complication associated with femoral intramedullary alignment guide in total knee arthroplasty
    Yau, WP
    Ng, TP
    Chiu, KY
    JOURNAL OF ARTHROPLASTY, 2001, 16 (02): : 247 - 249
  • [23] Extramedullary versus intramedullary femoral alignment technique in total knee arthroplasty: a meta-analysis of randomized controlled trials
    Qian Tang
    Ping Shang
    Gang Zheng
    Hua-Zi Xu
    Hai-Xiao Liu
    Journal of Orthopaedic Surgery and Research, 12
  • [24] Extramedullary versus intramedullary femoral alignment technique in total knee arthroplasty: a meta-analysis of randomized controlled trials
    Tang, Qian
    Shang, Ping
    Zheng, Gang
    Xu, Hua-Zi
    Liu, Hai-Xiao
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [25] THE ACCURACY OF INTRAMEDULLARY ALIGNMENT IN TOTAL KNEE REPLACEMENT
    MANNING, M
    ELLOY, M
    JOHNSON, R
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (05): : 852 - 852
  • [26] ACCURACY OF INTRAMEDULLARY ALIGNMENT IN TOTAL KNEE REPLACEMENT
    ELLOY, MA
    MANNING, MP
    JOHNSON, R
    JOURNAL OF BIOMEDICAL ENGINEERING, 1992, 14 (05): : 363 - 370
  • [27] Anterior Border of the Tibia as a Landmark for Extramedullary Alignment Guide in Total Knee Arthroplasty for Varus Knees
    Fukagawa, Shingo
    Matsuda, Shuichi
    Mitsuyasu, Hiroaki
    Miura, Hiromasa
    Okazaki, Ken
    Tashiro, Yasutaka
    Iwamoto, Yukihide
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (06) : 919 - 924
  • [28] Femoral Valgus Correction Angle for the Intramedullary Alignment Rod Is Strongly Associated with Femoral Lateral Bowing in Japanese Patients with Varus Knee Osteoarthritis Undergoing Total Knee Arthroplasty
    Hattori, Yosuke
    Asai, Nobuyuki
    Mori, Shotaro
    Ikuta, Ken
    Kazama, Yusuke
    Iesaki, Yusuke
    Takahashi, Shimpei
    Kaneko, Atsushi
    Sato, Tomotaro
    ADVANCES IN ORTHOPEDICS, 2022, 2022
  • [29] Femoral bowing affects varus femoral alignment but not patient satisfaction in mechanically aligned total knee arthroplasty
    Umatani, Naoki
    Kuriyama, Shinichi
    Nishitani, Kohei
    Nakamura, Shinichiro
    Ito, Hiromu
    Matsuda, Shuichi
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (01): : 89 - 96
  • [30] The Effects of Surgical Technique in Total Knee Arthroplasty for Varus Osteoarthritic Knee on the Rotational Alignment of Femoral Component: Gap Balancing Technique versus Measured Resection Technique
    Kim, Chang-Wan
    Lee, Chang-Rack
    Gwak, Heui-Chul
    Kim, Jung-Han
    Kwon, Yong-Uk
    Kim, Doo-Yeol
    JOURNAL OF KNEE SURGERY, 2020, 33 (02) : 144 - 151