Experimental study on the structural behaviors of jacking prestressed concrete cylinder pipe

被引:34
|
作者
Zhang, Yao [2 ]
Yan, Zhi-guo [1 ,2 ]
Zhu, He-hua [1 ,2 ]
Ju, J. Woody [3 ]
机构
[1] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, 1239 Siping Rd, Shanghai 200092, Peoples R China
[2] Tongji Univ, Dept Geotech Engn, 1239 Siping Rd, Shanghai 200092, Peoples R China
[3] Univ Calif Los Angeles, Dept Civil & Environm Engn, Los Angeles, CA 90095 USA
关键词
Structural behaviors; JPCCP; Combined load; Internal pressure; External load; PERFORMANCE;
D O I
10.1016/j.tust.2017.11.033
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, full-scale tests were conducted on Jacking Prestressed Concrete Cylinder Pipe (JPCCP) under external load, internal pressure, and combined load in order to evaluate its structural behaviors and possible failure modes. The experimental results indicate that external load plays a critical role in determining the onset of inner concrete core cracking at the invert and crown of a pipe. Once cracking appears in the inner concrete core of JPCCP under external load, the crack propagates rapidly and exhibits significant brittle fracture property. The onset of microcracking first appears in the exterior-reinforced concrete coating at the pipe springline in these three tests. Compared to the inner concrete core, cracks distributed in exterior-reinforced concrete coatings are smaller and narrower, as a result of the restriction imposed by the stirrup. The results of the combined load test show that JPCCP structure transforms from a perfect cycle into a damaged cycle, exhibiting a reduction in section stiffness at the pipe invert as loading increases. When the steel cylinder reaches its yield limit, the prestressing wire at the pipe invert yields soon after, and debonding (delamination) occurs between the steel cylinder and concrete almost simultaneously. Nevertheless, the JPCCP structure features excellent post-cracking capacity after a new equilibrium forms, and it exhibits enhanced ductile properties. Finally, a comparison between test results for JPCCP and Prestressed Concrete Cylinder Pipe (PCCP) is performed to illustrate the failure mode of JPCCP under combined load.
引用
收藏
页码:60 / 70
页数:11
相关论文
共 50 条
  • [31] Prestressed concrete cylinder pipe solves tough soil problems
    不详
    WATER-ENGINEERING & MANAGEMENT, 1999, 146 (06): : 13 - 13
  • [32] Rehabilitation of large diameter prestressed cylinder concrete pipe (PCCP) with FRP composites - Experimental investigation
    Lee, DC
    Karbhari, VM
    ADVANCES IN STRUCTURAL ENGINEERING, 2005, 8 (01) : 31 - 44
  • [33] Extending the life of Prestressed Concrete Cylinder Pipe with Pulse Cathodic Protection
    Doniguian, T
    Kipps, H
    Barnes, J
    PIPELINES IN THE CONSTRUCTED ENVIRONMENT, 1998, : 367 - 376
  • [34] Case history - Corrosion and cathodic protection of prestressed concrete cylinder pipe
    Gummow, RA
    MATERIALS PERFORMANCE, 2005, 44 (05) : 32 - 33
  • [35] Cathodic protection of prestressed concrete cylinder pipe utilizing zinc anodes
    Benedict, RL
    Ott, JG
    Marshall, DH
    White, D
    MATERIALS PERFORMANCE, 1997, 36 (05) : 12 - 16
  • [36] CFRP liner quality control for repair of prestressed concrete cylinder pipe
    Allan, A.
    Carr, H.
    CHALLENGES, OPPORTUNITIES AND SOLUTIONS IN STRUCTURAL ENGINEERING AND CONSTRUCTION, 2010, : 623 - +
  • [37] Using EPS and CFRP liner to strengthen prestressed concrete cylinder pipe
    Zhai, Kejie
    Fang, Hongyuan
    Guo, Chengchao
    Li, Bin
    Wang, Niannian
    Yang, Kangjian
    Zhang, Xijun
    Du, Xueming
    Di, Danyang
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 412
  • [38] Internal Joint Bonding of Prestressed Concrete Cylinder Pipe: The Improbable Project
    Smith, Greg
    PIPELINES 2020: UTILITY ENGINEERING, SURVEYING, AND MULTIDISCIPLINARY TOPICS, 2020, : 259 - 264
  • [39] Overload test and failure mechanism analysis of prestressed concrete cylinder pipe
    Hu, Shaowei
    Liu, Xiaoxin
    Shuili Fadian Xuebao/Journal of Hydroelectric Engineering, 2012, 31 (01): : 103 - 107
  • [40] EXPERIMENTAL EVALUATION OF DESIGN METHODS FOR PRESTRESSED CONCRETE PIPE
    ZARGHAMEE, MS
    HEGER, FJ
    DANA, WR
    JOURNAL OF TRANSPORTATION ENGINEERING-ASCE, 1988, 114 (06): : 635 - 655