A variety of popular instant, ground, and brewed coffees were analyzed using a modified liquid chromatography-tandem mass spectrometry (LC-MS/MS) method specifically developed for the determination of acrylamide in foods. Coffee test portions were spiked with C-13(3)-labeled acrylamide as an internal standard prior to their extraction and cleanup. Ground coffees (1 g) and instant coffees (0.5 g) were extracted by shaking with 9 mL of water for 20 min. Brewed coffee test portions (9 mL) were taken through the cleanup procedure without further dilution with extraction solvent. Coffee test portions were cleaned up by passing 1.5 mL first through an Oasis HLB (hydrophilic/lipophilic copolymer sorbent) solid phase extraction (SPE) cartridge and then a Bond Elut-Accucat (cation and anion exchange sorbent) SPE cartridge. The cleaned up extracts were analyzed by positive ion electrospray LC-MS/MS. The MS/MS data was used to detect, confirm, and quantitate acrylamide. The limit of quantitation of the method was 10 ng/g for ground and instant coffees and 1.0 ng/mL for brewed coffee. The levels of acrylamide ranged from 45 to 374 ng/g in unbrewed coffee grounds, from 172 to 539 ng/g in instant coffee crystals, and from 6 to 16 ng/mL in brewed coffee.
引用
收藏
页码:1996 / 2002
页数:7
相关论文
共 50 条
  • [31] MS analysis of LC fractions using an ettan LC-MS system
    Wadensten, H
    Salomonsson, I
    Lindqvist, S
    Renlund, S
    Berkova, M
    [J]. LC GC NORTH AMERICA, 2002, : 10 - 12
  • [32] Analysis of steroids in newborn screening by LC-MS/MS
    Fountain, Mark
    Klein, David
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 242
  • [33] The Analysis of Testosterone by LC-MS/MS (A Comparison with Immunoassay).
    McFarlane, John
    Liu, Hua-fen
    Fernandez, Beth
    Stone, Judith
    [J]. ENDOCRINE REVIEWS, 2010, 31 (03)
  • [34] Testosterone analysis in serum of women by LC-MS/MS
    Kushmir, MM
    Rockwood, AL
    Yue, B
    Roberts, WL
    Meikle, AW
    [J]. CLINICAL CHEMISTRY, 2004, 50 (06) : A91 - A92
  • [35] LC-MS/MS analysis of steroids in the clinical laboratory
    Keevil, Brian G.
    [J]. CLINICAL BIOCHEMISTRY, 2016, 49 (13-14) : 989 - 997
  • [36] LC-MS/MS analysis of organic toxics in food
    Núñez, O
    Moyano, E
    Galceran, MT
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (07) : 683 - 703
  • [37] Analysis of dutasteride in human serum by LC-MS/MS
    Nam, Hye-Seon
    Nam, Kyong-Hee
    Jung, Su Hee
    Lee, Jang Woo
    Kang, Jin Yeong
    Hong, Soon Keun
    Kim, Tae Sung
    Jung, Ki Kyung
    Kang, Tae Seok
    Yoon, Hae-Jung
    Lee, Kwang Ho
    Rhee, Gyu-Seek
    [J]. ANALYTICAL SCIENCE AND TECHNOLOGY, 2012, 25 (01): : 76 - 82
  • [38] Analysis of quinolones and Sulfonamides in meat by LC-MS/MS
    Zamoum, Radia
    Chebli, Akli
    Djerroud, Djedjiga
    Alamir, Barkahoum
    [J]. TOXICOLOGIE ANALYTIQUE ET CLINIQUE, 2021, 33 (01) : 64 - 73
  • [39] LC-MS/MS analysis of new "internet drugs"
    Stephanson, N.
    Al-Saffar, Y.
    Beck, O.
    [J]. THERAPEUTIC DRUG MONITORING, 2011, 33 (04) : 484 - 484
  • [40] Bottled water: Analysis of mycotoxins by LC-MS/MS
    Mata, A. T.
    Ferreira, J. P.
    Oliveira, B. R.
    Batoreu, M. C.
    Crespo, M. T. Barreto
    Pereira, V. J.
    Bronze, M. R.
    [J]. FOOD CHEMISTRY, 2015, 176 : 455 - 464