R1 dispersion contrast at high field with fast field-cycling MRI

被引:15
|
作者
Boedenler, Markus [1 ]
Basini, Martina [2 ,3 ]
Casula, Maria Francesca [4 ,5 ]
Umut, Evrim [6 ]
Goesweiner, Christian [1 ]
Petrovic, Andreas [1 ]
Kruk, Danuta [6 ]
Scharfetter, Hermann [1 ]
机构
[1] Graz Univ Technol, Inst Med Engn, Stremayrgasse 16, A-8010 Graz, Austria
[2] Univ Milan, Phys Dept, Via Celoria 16, I-20133 Milan, Italy
[3] Univ Milan, INSTM, Via Celoria 16, I-20133 Milan, Italy
[4] Univ Cagliari, Dept Chem & Soil Sci, I-09042 Monserrato, CA, Italy
[5] Univ Cagliari, INSTM, I-09042 Monserrato, CA, Italy
[6] Univ Warmia & Mazury, Fac Math & Comp Sci, Sloneczna 54, PL-10710 Olsztyn, Poland
关键词
Fast field-cycling; Dispersion; Delta relaxation enhanced MR; MRI; Quadrupole relaxation enhancement; Contrast agent; RELAXATION ENHANCED MR; MAGNETIC-RESONANCE; AGENTS;
D O I
10.1016/j.jmr.2018.03.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Contrast agents with a strong R-1 dispersion have been shown to be effective in generating target-specific contrast in MRI. The utilization of this R-1 field dependence requires the adaptation of an MRI scanner for fast field-cycling (FFC). Here, we present the first implementation and validation of FFC-MRI at a clinical field strength of 3 T. A field-cycling range of +/- 100 mT around the nominal Bo field was realized by inserting an additional insert coil into an otherwise conventional MRI system. System validation was successfully performed with selected iron oxide magnetic nanoparticles and comparison to FFC-NMR relaxometry measurements. Furthermore, we show proof-of-principle R-1 dispersion imaging and demonstrate the capability of generating R-1 dispersion contrast at high field with suppressed background signal. With the presented ready-to-use hardware setup it is possible to investigate MRI contrast agents with a strong R-1 dispersion at a field strength of 3 T. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:68 / 75
页数:8
相关论文
共 50 条
  • [31] Magnetic field-cycling investigations of molecular tunnelling
    Horsewill, AJ
    Xue, Q
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2002, 4 (22) : 5475 - 5480
  • [32] Field-cycling NMR and DNP - A friendship with benefits
    Gizatullin, Bulat
    Mattea, Carlos
    Stapf, Siegfried
    JOURNAL OF MAGNETIC RESONANCE, 2021, 322
  • [33] Field-cycling effects on dynamic nuclear polarization
    Miesel, K.
    Ivanov, K. L.
    Koechling, T.
    Yurkovskaya, A. V.
    Vieth, H. -M.
    APPLIED MAGNETIC RESONANCE, 2008, 34 (3-4) : 423 - 437
  • [35] Design of a fast field-cycling magnetic resonance imaging system, characterization and methods for relaxation dispersion measurements around 1.5 T
    Chanet, Nicolas
    Guillot, Genevieve
    Willoquet, Georges
    Jourdain, Laurene
    Dubuisson, Rose-Marie
    Reganha, Gael
    de Rochefort, Ludovic
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (02):
  • [36] Magnetic field compensation for field-cycling NMR relaxometry in the ULF band
    Anoardo, E
    Ferrante, GM
    APPLIED MAGNETIC RESONANCE, 2003, 24 (01) : 85 - 96
  • [37] Theory of fast field-cycling NMR relaxometry of liquid systems undergoing chemical exchange
    Fries, Pascal H.
    Belorizky, Elie
    MOLECULAR PHYSICS, 2019, 117 (7-8) : 849 - 860
  • [38] A fast field-cycling device for high-resolution NMR: Design and application to spin relaxation and hyperpolarization experiments
    Kiryutin, Alexey S.
    Pravdivtsev, Andrey N.
    Ivanov, Konstantin L.
    Grishin, Yuri A.
    Vieth, Hans-Martin
    Yurkovskaya, Alexandra V.
    JOURNAL OF MAGNETIC RESONANCE, 2016, 263 : 79 - 91
  • [39] Magnetic field compensation for field-cycling NMR Relaxometry in the ULF band
    E. Anoardo
    G. M. Ferrante
    Applied Magnetic Resonance, 2003, 24 : 85 - 96
  • [40] A whole-body Fast Field-Cycling scanner for clinical molecular imaging studies
    Broche, Lionel M.
    Ross, P. James
    Davies, Gareth R.
    Macleod, Mary-Joan
    Lurie, David J.
    SCIENTIFIC REPORTS, 2019, 9 (1)