Feasibility and safety of frequency-domain optical coherence tomography for coronary artery evaluation: a single-center study

被引:15
|
作者
Lehtinen, Tuomas [1 ,2 ]
Nammas, Wail [1 ]
Airaksinen, Juhani K. E. [2 ]
Karjalainen, Pasi P. [1 ]
机构
[1] Satakunta Cent Hosp, Ctr Heart, Pori 28500, Finland
[2] Turku Univ Hosp, Dept Med, Turku 20521, Finland
来源
关键词
Optical coherence tomography; Frequency-domain; Safety; Feasibility; ACUTE MYOCARDIAL-INFARCTION; MULTICENTER; LESION;
D O I
10.1007/s10554-013-0196-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We assessed the feasibility and safety of frequency-domain optical coherence tomography (FD-OCT) in a variety of indications. We conducted a retrospective analysis of all FD-OCT examinations performed for research and clinical indications, including stable angina, acute coronary syndromes, diagnostic procedures and percutaneous coronary intervention (PCI), at the Satakunta Central Hospital (Pori, Finland) between August 12th 2009 and February 9th 2011. All pullbacks were screened for image quality. Data on complications and clinical implications of examinations was obtained from patient records. The mean age of the patients was 65.9 +/- A 10.9 years (81.7 % males). A total of 230 examinations were performed on 210 patients; 523 pullbacks were eventually attempted (519 successful). On average, 2.3 +/- A 1.1 pullbacks were performed, and 1.1 +/- A 0.4 vessels were scanned per examination. PCI was performed in 44.3 % of examinations. Radial access was used in 70.3 % of cases. Examination was successful in 202 (87.8 %) examinations. One patient died of heart failure later after PCI for acute myocardial infarction. No cases of major bleeding, myocardial infarction, contrast-induced nephropathy, or pericardial tamponade were encountered. Chest pain occurred in 10.9 % of examinations, minor bleeding in 4.8 %, and myocardial ischemia in 2.6 %. Femoral access was associated with fewer blood and decentration artefacts and a trend towards better image quality when compared to radial access, with no difference in complications. After the first 50 examinations, there appeared to be fewer artefacts in the subsequent examinations. The current study demonstrated that FD-OCT is feasible, with infrequent complications.
引用
收藏
页码:997 / 1005
页数:9
相关论文
共 50 条
  • [21] Optical coherence tomography by adopting frequency-domain optical delay line
    Shi, Guo-Hua
    Ding, Zhi-Hua
    Rao, Xue-Jun
    Zhang, Yu-Dong
    Guangdian Gongcheng/Opto-Electronic Engineering, 2006, 33 (10): : 1 - 4
  • [22] Sex Differences in Nonculprit Coronary Plaque Microstructures on Frequency-Domain Optical Coherence Tomography in Acute Coronary Syndromes and Stable Coronary Artery Disease
    Kataoka, Yu
    Puri, Rishi
    Hammadah, Muhammad
    Duggal, Bhanu
    Uno, Kiyoko
    Kapadia, Samir R.
    Tuzcu, Murat
    Nissen, Steven E.
    King, Peta
    Nicholls, Stephen J.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2016, 9 (08)
  • [23] Gender differences in non-culprit coronary plaque microstructures on frequency-domain optical coherence tomography in stable coronary artery disease
    Kataoka, Y.
    Puri, R.
    Hammadah, M.
    Duggal, B.
    Uno, K.
    Kapadia, S. R.
    Tuzcu, E. M.
    Nissen, S. E.
    King, P. B.
    Nicholls, S. J.
    EUROPEAN HEART JOURNAL, 2016, 37 : 802 - 802
  • [24] Intravascular Frequency-domain Optical Coherence Tomography Imaging System
    Tao Kuiyuan
    Liu Tiegen
    Ding Zhenyang
    Zhou Yonghan
    Liu Kun
    Jiang Junfeng
    Hu Haofeng
    Kuang Hao
    Liu Zixu
    2016 15TH INTERNATIONAL CONFERENCE ON OPTICAL COMMUNICATIONS AND NETWORKS (ICOCN), 2016,
  • [25] Frequency-domain optical coherence tomography system in the terahertz region
    Hideaki Kitahara
    Masahiko Tani
    Masanori Hangyo
    Applied Physics B, 2020, 126
  • [26] Frequency-domain optical coherence tomography system in the terahertz region
    Kitahara, Hideaki
    Tani, Masahiko
    Hangyo, Masanori
    APPLIED PHYSICS B-LASERS AND OPTICS, 2020, 126 (01):
  • [27] Motion artifacts in optical coherence tomography with frequency-domain ranging
    Yun, SH
    Tearney, GJ
    de Boer, JF
    Bouma, BE
    OPTICS EXPRESS, 2004, 12 (13): : 2977 - 2998
  • [28] Advances in Optical Coherence Tomography: Frequency-domain Technology and Applications
    Yun, Seok Hyun
    2007 CONFERENCE ON LASERS & ELECTRO-OPTICS/QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2007), VOLS 1-5, 2007, : 1662 - 1663
  • [29] Feasibility of Intracoronary Frequency Domain Optical Coherence Tomography Derived Fractional Flow Reserve for the Assessment of Coronary Artery Stenosis
    Zafar, Haroon
    Sharif, Faisal
    Leahy, Martin J.
    INTERNATIONAL HEART JOURNAL, 2014, 55 (04) : 307 - 311
  • [30] Frequency-domain optical coherence tomography assessment of unprotected left main coronary artery disease-A comparison with intravascular ultrasound
    Fujino, Yusuke
    Bezerra, Hiram G.
    Attizzani, Guilherme F.
    Wang, Wei
    Yamamoto, Hirosada
    Chamie, Daniel
    Kanaya, Tomoaki
    Mehanna, Emile
    Tahara, Satoko
    Nakamura, Sunao
    Costa, Marco A.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (03) : E173 - E183