Rigid motion artifact reduction in CT using extended difference function

被引:1
|
作者
Zhang, Yuan [1 ]
Zhang, Liyi [1 ,2 ]
Sun, Yunshan [2 ]
机构
[1] Tianjin Univ, Sch Elect & Informat Engn, Tianjin, Peoples R China
[2] Tianjin Univ Commerce, Sch Informat Engn, Tianjin, Peoples R China
基金
中国博士后科学基金;
关键词
Computed Tomography (CT); extended difference function; fan-beam; motion estimation; motion artifacts; CONE-BEAM CT;
D O I
10.3233/XST-180442
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: In computed tomography (CT), a patient motion would result in degraded spatial resolution and image artifacts. OBJECTIVE: To eliminate motion artifacts, this study presents a method to estimate the motion parameters from sinograms based on extended difference function. METHODS: Based on our previous work, we first divide the projection data into two parts according to view angles and take Radon transform. Then, we calculate the extended difference functions and search for the minimum points. The relative displacements can be determined by the minimum points, and the motion can be estimated by the relationships between the relative displacements and motion parameters. Finally, we introduce the estimated parameters into the reconstruction process to compensate for the motion effects. RESULTS: The simulation results show that the running times can reduce by about 30% than our previous work. In phantom experiments, the relative mean rotation excursion (RMRE) and relative mean translation excursion (RMTE) of the new method are lower than the conventional Helgason-Ludwig consistency condition (HLCC) based method and comparable to our previous work. Compare with the HLCC method, the root mean square error (RMSE) of the new method also reduces, while the Pearson correlation coefficient (CC) and mean structural similarity index (MSSIM) increase. CONCLUSIONS: The proposed new method yields the improved performance on accuracy of motion estimation with higher computational efficiency, and thus it can produce high-quality images.
引用
收藏
页码:273 / 285
页数:13
相关论文
共 50 条
  • [1] Rigid motion artifact reduction in CT using frequency domain analysis
    Zhang, Yuan
    Zhang, Liyi
    Sun, Yunshan
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (05) : 721 - 736
  • [2] Rigid Motion Artifact Reduction in CT Using the Phase Correlation Method
    Zhang, Yuan
    Zhang, Liyi
    Sun, Yunshan
    [J]. RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2020, 13 (08) : 1119 - 1128
  • [3] A Rigid Motion Artifact Reduction Method for CT Based on Blind Deconvolution
    Zhang, Yuan
    Zhang, Liyi
    [J]. ALGORITHMS, 2019, 12 (08)
  • [4] Rigid and non-rigid motion artifact reduction in X-ray CT using attention module
    Ko, Youngjun
    Moon, Seunghyuk
    Baek, Jongduk
    Shim, Hyunjung
    [J]. MEDICAL IMAGE ANALYSIS, 2021, 67
  • [5] Data consistency based rigid motion artifact reduction in fan-beam CT
    Yu, Hengyong
    Wang, Ge
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (02) : 249 - 260
  • [6] Reduction of motion blurring artifact using respiratory gated CT: A quantitative evaluation
    Lu, W
    Parikh, P
    Hubenschmidt, J
    Politte, D
    Whiting, B
    Bradley, J
    Low, D
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2056 - 2056
  • [8] Motion artifact compensation in CT
    Zerfowski, D
    [J]. MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 : 416 - 424
  • [9] Artifact reduction using segmentation constrained RPCA for CT
    Kim, Y.
    Choi, D.
    Lim, S.
    Cho, S.
    [J]. INTERNATIONAL FORUM ON MEDICAL IMAGING IN ASIA 2019, 2019, 11050
  • [10] Artifact reduction in truncated CT using Sinogram completion
    Chityala, R
    Hoffmann, KR
    Rudin, S
    Bednarek, DR
    [J]. Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 2110 - 2117