Effect of the cut-off frequency on rough-point and flat-surface contacts?

被引:7
|
作者
Meng, Fanming [1 ]
机构
[1] Chongqing Univ, State Key Lab Mech Transmiss, Chongqing 400044, Peoples R China
关键词
Rough point contact; Rough flat surface contact; Cut-off frequency; Conjugate gradient method; Contact radius; ENGINEERING SURFACES; MODEL; DEFORMATION; WEAR;
D O I
10.1007/s12206-012-0712-0
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In the past years, contact between two bodies has been studied from various ways that do not consider the cut-off frequency effect on the contact mechanism. This paper reports the correlation between rough point contact and flat surface contact at different cut-off frequencies of filter. The similarity and difference between the two types of contact mechanisms are presented for materials with linear or elasticperfectly plastic deformation. The conjugate gradient method (CGM) is used for analysing the rough point contact, while the rough flat surface contact is studied with an improved CGM in which the influence coefficient for the elastic deformation of the rough flat surface is obtained with finite element method. Numerical results show that for the above two types of contacts, their von Mises stress and maximum shear stress are greatly affected by the cut-off frequency of a high-pass filter. Moreover, a decrease in the cut-off frequency leads to an increase in the contact area and a decrease in the approach for the rough flat surface contact, while the opposite variations is for the point contact between rough bodies with the small radii.
引用
收藏
页码:2889 / 2901
页数:13
相关论文
共 50 条
  • [21] Effect of Co ions substitute on the cut-off frequency of NiZn ferrites
    State Key Laboratory of Electronic Thin Films and Integrated Devices, Chengdu 610054, China
    不详
    Gongneng Cailiao, 2008, 5 (754-756+760):
  • [22] The Higgs mechanism as a cut-off effect
    Irges, Nikos
    Knechtli, Francesco
    Luz, Magdalena
    JOURNAL OF HIGH ENERGY PHYSICS, 2007, (08):
  • [23] MICELLIZATION AS THE ORIGIN OF THE CUT-OFF EFFECT IN HOMOLOGOUS SERIES OF SURFACE ANESTHETICS
    ECKERT, T
    WACHTEL, E
    ARZNEIMITTEL-FORSCHUNG/DRUG RESEARCH, 1983, 33-1 (01): : 98 - 100
  • [24] On the redshift cut-off for flat-spectrum radio sources
    Jarvis, MJ
    Rawlings, S
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2000, 319 (01) : 121 - 136
  • [25] Circuit model for flat cut-off probes with coplanar capacitance
    Yeom, H. J.
    You, K. H.
    Kim, Jung-Hyung
    Lee, Hyo-Chang
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2021, 30 (06):
  • [26] Cut-off point of the Scoliometer in school scoliosis screening
    Huang, SC
    SPINE, 1997, 22 (17) : 1985 - 1989
  • [27] Fetus as Human Being: Where is the Cut-off Point?
    Dabbagh, Soroush
    JOURNAL OF MEDICAL ETHICS AND HISTORY OF MEDICINE, 2009, 2
  • [28] Emission noise and high frequency cut-off of the Kondo effect in a quantum dot
    Delagrange, R.
    Basset, J.
    Bouchiat, H.
    Deblock, R.
    PHYSICAL REVIEW B, 2018, 97 (04)
  • [29] The effect of electronic components on the cut-off frequency of the hot-wire system
    Li, JD
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (03) : 766 - 774
  • [30] Boron spike effect on cut-off frequency and early voltage in SiGe HBTs
    Hashimoto, T.
    Sato, F.
    Tatsumi, T.
    Tashiro, T.
    1995,