Quantitative evaluation of contrast enhanced transcranial Doppler signal using galactose based echo-contrast agent in dogs

被引:2
|
作者
Chung, Woojo
Choi, Hojung
Lee, Kichang
Lee, Heechun
Choi, Mincheol
Yoon, Junghee
机构
[1] Seoul Natl Univ, Coll Vet Med, Seoul 151742, South Korea
[2] Chungnam Natl Univ, Coll Vet Med, Taejon 305764, South Korea
[3] Chonbuk Natl Univ, Coll Vet Med, Jeongu 561756, South Korea
[4] Gyeongsang Natl Univ, Jinju 660701, South Korea
来源
JOURNAL OF VETERINARY MEDICAL SCIENCE | 2006年 / 68卷 / 06期
关键词
canine; galactose based echo-contrast agent; right middle cerebral artery; transcranial Doppler;
D O I
10.1292/jvms.68.597
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Transcranial Doppler ultrasonography (TCD) is hindered by insufficient ultrasound penetration through the temporal bone. The use of echo-contrast agents to enhance the Doppler signal is an important step toward the solution of this problem. The aim of the present study was to investigate the tolerability and diagnostic value of the intravenous echo-contrast agent, Levovist (R). Levovist (R) was administered intravenously in 8 dogs with two doses (0.2 and 0.3 ml/kg) at different concentrations (300 and 400 mg/ml). In right middle cerebral artery (RMCA), the duration and degree of the signal enhancement were measured by TCD. All 32 administrations of Levovist, produced an increase in TCD signal of the RMCA without complications. The first assessable pulse curve could be seen on the screen after 4 to 7 seconds after injection. There was no significant difference of latency period between different concentration and dosage. The signal amplitude was increased homogeneously by more than 30 dB when 0.3 ml/kg with 300 mg/ml concentration of Levovist (R) and 0.2 and 0.3 ml/kg with 400 mg/ml concentration were administered. There was no significant difference in the duration of optimal contrasting between 0.3 ml/kg with 300 mg/ml concentration of Levovist (R) and 0.2 and 0.3 ml/kg with 400 mg/ml concentration. The duration of the signal enhancement was 144 to 422 seconds, depending on the degree of concentration and dose of administration. Optimal TCD signal enhancement of RMCA was obtained using 0.3 ml/kg with 300 mg/ml concentration of Levovis (R) in dogs, which is considered to provide quality visualization.
引用
收藏
页码:597 / 601
页数:5
相关论文
共 50 条
  • [31] Perforating veins in recurrent esophageal varices evaluated by endoscopic color Doppler ultrasonography with a galactose-based contrast agent
    Sato, T
    Yamazaki, K
    Toyota, J
    Karino, Y
    Ohmura, T
    Akaike, J
    Kuwata, Y
    Suga, T
    JOURNAL OF GASTROENTEROLOGY, 2004, 39 (05) : 422 - 428
  • [32] Perforating veins in recurrent esophageal varices evaluated by endoscopic color Doppler ultrasonography with a galactose-based contrast agent
    Takahiro Sato
    Katsu Yamazaki
    Jouji Toyota
    Yoshiyasu Karino
    Takumi Ohmura
    Jun Akaike
    Yasuaki Kuwata
    Toshihiro Suga
    Journal of Gastroenterology, 2004, 39 : 422 - 428
  • [33] Usefulness of an echo-contrast agent for assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery with transthoracic Doppler scan echocardiography
    Okayama, H
    Sumimoto, T
    Hiasa, G
    Morioka, N
    Yamamoto, K
    Kawada, H
    AMERICAN HEART JOURNAL, 2002, 143 (04) : 668 - 675
  • [34] Editorial for "Enhanced Mass on Contrast-Enhanced BreastMRI: Differentiation Using a Combination of Dynamic Contrast-EnhancedMRIand Quantitative Evaluation With SyntheticMRI"
    Kulshreshtha, Manjari
    Sharma, Uma
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (02) : 392 - 393
  • [35] Assessment of cerebral autoregulation with transcranial Doppler sonography in poor bone windows using constant infusion of an ultrasound contrast agent
    Lorenz, Matthias W.
    Thoelen, Nina
    Loesel, Nadine
    Lienerth, Christian
    Gonzalez, Marilen
    Humpich, Marek
    Roelz, Waltraud
    Dvorak, Florian
    Sitzer, Matthias
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (03): : 345 - 353
  • [36] Evaluation of coronary reserve in the left anterior descending coronary artery by contrast-enhanced transthoracic harmonic echo Doppler
    Caiati, C
    Montaldo, C
    Zedda, N
    Ruscazio, M
    Pirisi, R
    Iliceto, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 201A - 201A
  • [37] Quantitative evaluation of renal parenchymal perfusion using contrast-enhanced ultrasonography in renal ischemia-reperfusion injury in dogs
    Lee, Gahyun
    Jeon, Sunghoon
    Lee, Sang-kwon
    Cheon, Byunggyu
    Moon, Sohyeon
    Park, Jun-Gyu
    Cho, Kyoung-Oh
    Choi, Jihye
    JOURNAL OF VETERINARY SCIENCE, 2017, 18 (04) : 507 - 514
  • [38] Improved Contrast-Enhanced Power Doppler Using a Coherence-Based Estimator
    Tremblay-Darveau, Charles
    Bar-Zion, Avinoam
    Williams, Ross
    Sheeran, Paul S.
    Milot, Laurent
    Loupas, Thanasis
    Adam, Dan
    Bruce, Matthew
    Burns, Peter N.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (09) : 1901 - 1911
  • [39] Contrast-enhanced ultrasonography findings using a perflubutane-based contrast agent in patients with early hepatocellular carcinoma
    Numata, Kazushi
    Fukuda, Hiroyuki
    Miwa, Haruo
    Ishii, Tomohiro
    Moriya, Satoshi
    Kondo, Masaaki
    Nozaki, Akito
    Morimoto, Manabu
    Okada, Masahiro
    Takebayashi, Shigeo
    Maeda, Shin
    Nozawa, Akinori
    Nakano, Masayuki
    Tanaka, Katsuaki
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (01) : 95 - 102
  • [40] Evaluation of malignant and benign breast tumors by D-galactose based signal enhanced Doppler sonography
    Schroeder, RJ
    Hadijuana, JC
    Hidajat, N
    Vogl, TJ
    Maeurer, J
    Felix, R
    RADIOLOGY, 1997, 205 : 1483 - 1483