Green roofs have shown a remarkable effect on the reduction of the building cooling load in summer. The assessment of the thermal performance of green roofs is essential for their design and evaluation. This study investigated the thermal characteristics of an extensive green roof under air-conditioned and non-air-conditioned states by using experimental data obtained on successive sunny summer days. Two indices of the green roof, namely the equivalent thermal resistance and the equivalent decrement factor, were estimated through comparison with a common bare roof. Under the non-air-conditioned state, the distribution of the average temperature on the green roof profile was S-sharp. The lowest average temperature of the green roof was observed on the interface between the planting soil and roof structure, which were 1.8 and 0.9 degrees C below the outdoor and indoor air temperature, respectively. This finding indicated that the bottom of the soil layer functioned as a "cooling source" that absorbed heat from the upside and downside. The indoor critical air temperature that maintains the heat flux equal to zero was investigated on the basis of the experimental data. The influence of indoor critical air temperature on the equivalent thermal resistance was discussed; for the same green roof under the same outdoor climatic conditions, an indoor air temperature that is closer to the indoor critical air temperature yields a higher equivalent thermal resistance. Therefore, the equivalent thermal resistance of the green roof obtained under low indoor air temperature is recommended for practical use.
引用
收藏
页码:1010 / 1021
页数:12
相关论文
共 50 条
  • [21] Impact of climatic conditions on the thermal effectiveness of an extensive green roof
    Lin, Bau-Show
    Yu, Chin-Chung
    Su, Ai-Tsen
    Lin, Yann-Jou
    [J]. BUILDING AND ENVIRONMENT, 2013, 67 : 26 - 33
  • [22] Thermal Study on Extensive Green Roof Integrated Irrigation in Northwestern Arid Regions of China
    Wang, Yajun
    Singh, Rajendra Prasad
    Fu, Dafang
    Zhang, Junyu
    Zhou, Fang
    [J]. WATER, 2017, 9 (11)
  • [23] THERMAL PERFORMANCE OF AN EXTENSIVE GREEN ROOF UNDER SEMI-ARID CONDITIONS IN CENTRAL ARGENTINA
    Imhof, Lelia
    Suarez, Edgardo
    Caceres, Natalia
    Robbiati, Federico
    Caceres, Cecilia
    Broilo, Alejandra
    Pellizari, Lucila
    Suarez, Mario
    Hick, Emmanuel
    Matoff, Evangelina
    Galetto, Leonardo
    [J]. JOURNAL OF GREEN BUILDING, 2021, 16 (01): : 17 - 42
  • [24] Seasonal and Diurnal Thermal Performance of a Subtropical Extensive Green Roof: The Impacts of Background Weather Parameters
    Peng, Lilliana L. H.
    Jim, C. Y.
    [J]. SUSTAINABILITY, 2015, 7 (08): : 11098 - 11113
  • [25] Thermal and energy performance of green roof and cool roof: A comparison study in Shanghai area
    He, Yang
    Yu, Hang
    Ozaki, Akihito
    Dong, Nannan
    [J]. JOURNAL OF CLEANER PRODUCTION, 2020, 267
  • [26] Experimental and Numerical Study on the Insulation Performance of a Photo-Thermal Roof in Hot Summer and Cold Winter Areas
    Zhang, Ying
    Sun, Hongfa
    Long, Jibo
    Zeng, Li
    Shen, Xiaohang
    [J]. BUILDINGS, 2022, 12 (04)
  • [27] Experimental study of the thermal protection performance of the high reflectivity-phase change material (PCM) roof in summer
    Meng, Erlin
    Wang, Junqi
    Yu, Hang
    Cai, Ruonan
    Chen, Yizhong
    Zhou, Bo
    [J]. BUILDING AND ENVIRONMENT, 2019, 164
  • [28] Study on delayed discharge time of extensive green roof
    Zhang, Hua
    Cao, Jinlu
    Li, Mao
    Zhang, Feng
    [J]. Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2015, 48 : 391 - 395
  • [29] Effects of slopes on the stormwater attenuation performance in extensive green roof
    Chow, M. F.
    Abu Bakar, M. F.
    Razali, M. H. Mohd
    [J]. 2018 2ND INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL SCIENCE, 2018, 164
  • [30] Experimental study of the thermal performance of a new type of PV roof
    Tian, Ruian
    Meng, Erlin
    Shu, Yue
    Li, Jun
    Zhou, Bo
    Zhao, Haiqian
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 157