An Evaluation of the NICCI Monitor in Providing Continuous, Noninvasive Blood Pressure Readings in Children During Intraoperative Anesthetic Care

被引:0
|
作者
Bekiroglu, Ismail [1 ]
Owusu-Bediako, Kwaku [1 ,3 ]
Rice-Weimer, Julie [1 ]
Tobias, Joseph D. [1 ,2 ]
机构
[1] Nationwide Childrens Hosp, Dept Anesthesiol & Pain Med, Columbus, OH USA
[2] Ohio State Univ, Dept Anesthesiol & Pain Med, Columbus, OH USA
[3] Nationwide Childrens Hosp, Dept Anesthesiol & Pain Med, Columbus, OH 43205 USA
来源
关键词
Arterial blood pressure; Blood pressure monitors; Pediat-rics anesthesiology; Intraoperative monitoring; CNAP(TM) MONITOR; ACCURACY; DEVICE; COMPLICATIONS; CANNULATION;
D O I
10.14740/jocmr4723
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In specific clinical scenarios or with patient comorbid con-ditions, continuous blood pressure (BP) monitoring may be required as it can be expected to provide superior physiologic monitoring to intermit-tent techniques. However, continuous BP monitoring requires an arte-rial cannula (AC) placement, which may be time-consuming, technically challenging, or associated with adverse events. Various noninvasive BP devices have been developed which provide a continuous BP reading. The current study evaluates the accuracy of a novel continuous BP de-vice, the NICCI monitor (NM), in pediatric patients weighing 10 -40 kg.Methods: The study cohort included pediatric patients weighing be-tween 10 and 40 kg, scheduled for surgery for which placement of an AC was planned. Systolic (SBP), diastolic (DBP), and mean arterial (MAP) blood pressure readings were captured from the AC and the NM every second during anesthetic care.Results: The study cohort included 24 pediatric patients undergoing major orthopedic, cardiac, and neurosurgical procedures. A total of 146,562 pairs of SBP, DBP, and MAP values from the AC and NC were analyzed. The absolute difference for the NM and the AC's SBP, DBP, and MAP values were 11 +/- 9, 10 +/- 7, and 10 +/- 7 mm Hg, re-spectively. The difference between the BP values from the NM and the AC was <= 10 mm Hg for 57% of the SBP readings, 60% of the DBP readings, and 56% of the MAP readings. The bias was 4, 4, and 6 mm Hg for the SBP, DBP, and MAP, respectively.Conclusions: Although there were some technical limitations given pa-tient size, potentially resulting in variation in accuracy, the NM provided a continuous noninvasive BP measurement within clinically useful lim-its during a significant portion of anesthetic care compared to values ob- tained from an AC. Ongoing modification of the technology to improve its application in pediatric patients will likely increase its accuracy.
引用
收藏
页码:158 / 164
页数:7
相关论文
共 50 条
  • [41] Evaluation of the Omron 705-CP blood pressure monitor for use in children and adolescents
    Furusawa, EA
    Ruiz, MFO
    Saito, MI
    Koch, VH
    [J]. JOURNAL OF HYPERTENSION, 2004, 22 : S140 - S140
  • [42] CLINICAL-EVALUATION OF THE CALIBRATION OF NONINVASIVE CONTINUOUS BLOOD-PRESSURE MEASUREMENT DEVICES BY MEANS OF OSCILLOMETRIC BLOOD-PRESSURE MEASUREMENTS
    DEJONG, JR
    ROS, HH
    DELANGE, JJ
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1993, 70 : 8 - 8
  • [43] A DIRECT ASSESSMENT OF NONINVASIVE CONTINUOUS BLOOD PRESSURE MONITORING IN THE EMERGENCY D EPARTMENT AND INTENSIVE CARE UNIT
    Hamilton, Landon D.
    Binns, Scott
    Mcfann, Kim
    Nudell, Nikiah
    Dunn, Julie A.
    [J]. JOURNAL OF EMERGENCY NURSING, 2024, 50 (04) : 503 - 515
  • [44] Comparison of intraoperative blood pressure values measured by noninvasive versus invasive methods during normotension, hypertension, and hypotension
    Irimpan, Joel
    Kesavan, Rajesh
    Rajan, Sunil
    Kumar, Lakshmi
    [J]. JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2024, 40 (02) : 258 - 263
  • [45] CIRCULATORY RESPONSES IN CHILDREN WITH UNEXPLAINED SYNCOPE EVALUATED BY CONTINUOUS NONINVASIVE FINGER BLOOD-PRESSURE MONITORING
    TANAKA, H
    THULESIUS, O
    YAMAGUCHI, H
    MINO, M
    [J]. ACTA PAEDIATRICA, 1994, 83 (07) : 754 - 761
  • [46] Noninvasive Blood Pressure Monitor Designed for Patients With Heart Failure Supported with Continuous-Flow Left Ventricular Assist Devices
    Sajgalik, Pavol
    Kremen, Vaclav
    Fabian, Vratislav
    Maltais, Simon
    Stulak, John M.
    Kushwaha, Sudhir S.
    Joyce, Lyle D.
    Schirger, John A.
    Johnson, Bruce D.
    [J]. ASAIO JOURNAL, 2019, 65 (02) : 127 - 133
  • [47] NONINVASIVE CONTINUOUS BLOOD-PRESSURE MEASUREMENT - A CLINICAL-EVALUATION OF THE CORTRONIC APM-770
    DEJONG, JR
    TEPASKE, R
    SCHEFFER, GJ
    ROS, HH
    SIPKEMA, PP
    DELANGE, JJ
    [J]. JOURNAL OF CLINICAL MONITORING, 1993, 9 (01): : 18 - 24
  • [48] Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit
    Nicolas Langwieser
    Luisa Prechtl
    Agnes S. Meidert
    Alexander Hapfelmeier
    Christian Bradaric
    Tareq Ibrahim
    Karl-Ludwig Laugwitz
    Roland M. Schmid
    Julia Y. Wagner
    Bernd Saugel
    [J]. Clinical Research in Cardiology, 2015, 104 : 518 - 524
  • [49] Mobile Personal Health Care System for Noninvasive, Pervasive, and Continuous Blood Pressure Monitoring: Development and Usability Study
    Mena, Luis J.
    Felix, Vanessa G.
    Ostos, Rodolfo
    Gonzalez, Armando J.
    Martinez-Pelaez, Rafael
    Melgarejo, Jesus D.
    Maestre, Gladys E.
    [J]. JMIR MHEALTH AND UHEALTH, 2020, 8 (07):
  • [50] Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit
    Langwieser, Nicolas
    Prechtl, Luisa
    Meidert, Agnes S.
    Hapfelmeier, Alexander
    Bradaric, Christian
    Ibrahim, Tareq
    Laugwitz, Karl-Ludwig
    Schmid, Roland M.
    Wagner, Julia Y.
    Saugel, Bernd