High resolution x-ray photon-counting detector with scintillator-deposited charge-coupled device

被引:9
|
作者
Miyata, E [1 ]
Tawa, N
Mukai, K
Tsunerni, H
Miyaguchi, K
机构
[1] Osaka Univ, Grad Sch Sci, Dept Earth & Space Sci, Osaka 5600043, Japan
[2] Div Solid State, Hamamatsu, Shizuoka 4358558, Japan
关键词
charge-coupled device (CCD); hard X-ray detector; photon counting; scintillator; high resolution imaging;
D O I
10.1109/TNS.2006.872638
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report on a new photon-counting detector possessing unprecedented spatial resolution and moderate spectral resolution for 0.1-100 keV X-rays. It consists of an X-ray charge-coupled device (CCD) and a scintillator. The scintillator is directly coupled to the back surface of the X-ray CCD. Low-energy X-rays below 10 keV can be directly detected by the CCD. The majority of hard X-rays above 10 keV pass through the CCD but can be absorbed by the scintillator, generating visible photons. We coupled needlelike CsI(Tl) on the front surface of the back-illuminated (BI) CCD. The high detection efficiency of BI CCDs in the visible band enables us to collect visible photons emitted from the CsI(TI) efficiently, leading to the moderate spectral resolution of 28.4% at 22.1 keV and 25% at 59.5 keV. We also investigated the imaging capability of our device and demonstrated high resolution imaging with an accuracy of 10 +/- 3 mu m at 17.4 keV.
引用
收藏
页码:576 / 583
页数:8
相关论文
共 50 条
  • [31] Charge-coupled device fiber optic taper array x-ray detector for protein crystallography
    Naday, I
    Ross, S
    Westbrook, EM
    Zentai, G
    OPTICAL ENGINEERING, 1998, 37 (04) : 1235 - 1244
  • [32] Novel photon-counting detector for 0.1-100 keV X-ray imaging possessing high spatial resolution
    Miyata, E
    Tamura, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2003, 42 (10A): : L1201 - L1204
  • [33] Novel Photon-Counting Detector for 0.1-100 keV X-Ray Imaging Possessing High Spatial Resolution
    Miyata, Emi
    Tamura, Keisuke
    Japanese Journal of Applied Physics, Part 2: Letters, 2003, 42 (10 A):
  • [34] Development of a high-resolution x-ray imaging system with a charge-coupled-device detector coupled with crystal x-ray magnifiers
    Sato, K
    Hasegawa, Y
    Kondo, K
    Miyazaki, K
    Matsushita, T
    Amemiya, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (12): : 4449 - 4456
  • [35] Modeling Spectral Distortions in Energy Resolved Photon-counting X-ray Detector
    Wang, Xiaolan
    Meier, Dirk
    Hugg, James
    Chowdhury, Samir
    Wagenaar, Douglas
    Patt, Bradley
    Frey, Eric
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3054 - 3057
  • [36] Photon-counting x-ray detectors for CT
    Danielsson, Mats
    Persson, Mats
    Sjolin, Martin
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03):
  • [37] X-ray spectroscopy with a photon-counting SiPM-based scintillation detector
    Ceravolo, S.
    Gargiulo, R.
    Paesani, D.
    Russo, A.
    Sarra, I.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (09)
  • [38] Spectral X-ray phase contrast imaging with a CdTe photon-counting detector
    Navarrete, Carlos
    Procz, Simon
    Schuetz, Michael Kilian
    Roque, Gerardo
    Fey, Julian
    Avila, Carlos
    Olivo, Alessandro
    Fiederle, Michael
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 971 (971):
  • [39] Biomedical x-ray imaging with a GaAs photon-counting detector: A comparative study
    Scholz, J.
    Birnbacher, L.
    Petrich, C.
    Riedel, M.
    Heck, L.
    Gkoumas, S.
    Sellerer, T.
    Achterhold, K.
    Herzen, J.
    APL PHOTONICS, 2020, 5 (10)
  • [40] DIRECT X-RAY SENSITIVE CHARGE-COUPLED DEVICE (CCD) AS A DETECTOR IN THE STUDY OF SYNCHROTRON SECTION TOPOGRAPHS
    TUOMI, T
    PARTANEN, J
    SIMOMAA, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 61 (04): : 569 - 574