High resolution x-ray photon-counting detector with scintillator-deposited charge-coupled device

被引:9
|
作者
Miyata, E [1 ]
Tawa, N
Mukai, K
Tsunerni, H
Miyaguchi, K
机构
[1] Osaka Univ, Grad Sch Sci, Dept Earth & Space Sci, Osaka 5600043, Japan
[2] Div Solid State, Hamamatsu, Shizuoka 4358558, Japan
关键词
charge-coupled device (CCD); hard X-ray detector; photon counting; scintillator; high resolution imaging;
D O I
10.1109/TNS.2006.872638
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report on a new photon-counting detector possessing unprecedented spatial resolution and moderate spectral resolution for 0.1-100 keV X-rays. It consists of an X-ray charge-coupled device (CCD) and a scintillator. The scintillator is directly coupled to the back surface of the X-ray CCD. Low-energy X-rays below 10 keV can be directly detected by the CCD. The majority of hard X-rays above 10 keV pass through the CCD but can be absorbed by the scintillator, generating visible photons. We coupled needlelike CsI(Tl) on the front surface of the back-illuminated (BI) CCD. The high detection efficiency of BI CCDs in the visible band enables us to collect visible photons emitted from the CsI(TI) efficiently, leading to the moderate spectral resolution of 28.4% at 22.1 keV and 25% at 59.5 keV. We also investigated the imaging capability of our device and demonstrated high resolution imaging with an accuracy of 10 +/- 3 mu m at 17.4 keV.
引用
收藏
页码:576 / 583
页数:8
相关论文
共 50 条
  • [1] High resolution X-ray photon-counting detector with scintillator-deposited charge-coupled device
    Miyata, E
    Tawa, N
    Mukai, K
    Tsunemi, H
    Miyaguchi, K
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 1014 - 1018
  • [2] Unprecedented imaging capability hard X-ray detector employing scintillator-deposited charge-coupled device
    Miyata, E
    Tawa, N
    Koizumi, G
    Mlki, M
    Miyaguchi, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2004, 43 (6B): : L808 - L810
  • [3] X-ray responsivities of direct-scintillator-deposited charge-coupled device
    Miyata, E
    Miki, M
    Tawa, N
    Miyaguchi, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (03): : 1476 - 1484
  • [4] X-ray responsivities of direct-scintillator-deposited charge-coupled device
    Miyata, Emi
    Miki, Masami
    Tawa, Noriaki
    Miyaguchi, Kazuhisa
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2005, 44 (03): : 1476 - 1484
  • [5] Optimization of a scintillator-deposited charge-coupled device with Monte-Carlo simulation
    Tawa, Noriaki
    Mukai, Kenji
    Ikegami, Kazuhiro
    Miyata, Emi
    Anabuki, Naohisa
    Tsunemi, Hiroshi
    Miyaguchi, Kazuhisa
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (1-2): : 119 - 121
  • [6] Wide-band imaging spectrometer with scintillator-deposited charge-coupled device
    Miyata, E.
    Anabuki, N.
    Mukai, K.
    Tawa, N.
    Miyauchi, T.
    Tsunemi, H.
    Miyaguchi, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (01): : 149 - 152
  • [7] Development of the scintillator-deposited charge-coupled device and application for the balloon-borne experiment, SUMIT
    Miyata, E.
    Mukai, K.
    Ikegami, K.
    Tawa, N.
    Anabuki, N.
    Tsunemi, H.
    Ogasaka, Y.
    Tamura, K.
    Furuzawa, A.
    Shibata, R.
    Haba, Y.
    Kunieda, H.
    Saito, Y.
    Yamagami, T.
    Miyaguchi, K.
    SPACE TELESCOPES AND INSTRUMENTATION II: ULTRAVIOLET TO GAMMA RAY, PTS 1 AND 2, 2006, 6266
  • [8] MicroComputed tomography with a photon-counting X-ray detector
    Frey, Ec.
    Taguchi, K.
    Kapusta, M.
    Xu, J.
    Orskaug, T.
    Ninive, I.
    Wagenaar, D.
    Patt, B.
    Tsui, B. M. W.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [9] Area x-ray detector based on a lens-coupled charge-coupled device
    Tate, MW
    Chamberlain, D
    Gruner, SM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (08): : 1 - 10
  • [10] Energy spectrometer on a diffractometer using a charge-coupled device X-ray detector
    Abe, Hiroshi
    Saitoh, Hiroyuki
    Nakao, Hironori
    Ito, Kazuki
    Ohshima, Ken-ichi
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2006, 39 : 767 - 770