Comparison of 12 deformable registration strategies in adaptive radiation therapy for the treatment of head and neck tumors

被引:166
|
作者
Castadot, Pierre [1 ]
Lee, John Aldo [1 ]
Parraga, Adriane [2 ,3 ]
Geets, Xavier [1 ]
Macq, Benoit [3 ]
Gregoire, Vincent [1 ]
机构
[1] Catholic Univ Louvain, St Luc Univ Hosp, Dept Radiat Oncol, Brussels, Belgium
[2] Univ Fed Rio Grande do Sul, Signal & Image Proc Lab, Porto Alegre, RS, Brazil
[3] Catholic Univ Louvain, Commun & Remote Sensing Lab, B-3000 Louvain, Belgium
关键词
Deformable registration algorithms; Adaptive radiotherapy; Head and neck cancer;
D O I
10.1016/j.radonc.2008.04.010
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Weight loss, tumor shrinkage, and tissue edema induce substantial modification of patient's anatomy during head and neck (HN) radiotherapy (RT) or chemo-radiotherapy. These modifications may impact on the dose distribution to both target volumes (TVs) and organs at risk (OARs). Adaptive radiotherapy (ART) where patients are re-imaged and re-planned several times during the treatment is a possible strategy to improve treatment delivery. It however requires the use of specific deformable registration (DR) algorithms that requires proper validation on a clinical material. Materials and methods: Twelve voxel-based DR strategies were compared with a dataset of 5 patients imaged with computed tomography (CT) before and once during RT (on average after a mean dose of 36.8 Gy): level-set (LS), level-set implemented in multi-resolution (LSMR), Demons' algorithm implemented in multi-resolution (D-MR), D-MR followed by LS (D-MR-LS), fast free-form deformable registration via calculus of variations (F3CV) and F3CV followed by LS (F3CV-LS). The use of an edge-preserving denoising filter called "local M-smoothers" applied to the registered images and combined to all the aforesaid strategies was also tested (fLS, fLS(MR), fD(MR), fD(MR)-LS, fF3CV, fF3CV-LS). All these strategies were compared to a rigid registration based on mutual information (MI, fMI). Chronological and anti-chronological registrations were also studied. The various DR strategies were evaluated using a volume-based criterion (i.e. Dice similarity index, DSI) and a voxel-intensity criterion (i.e. correlation coefficient, CC) on a total of 18 different manually contoured volumes. Results: For the DSI analysis, the best three strategies were D-MR, fD(MR)-LS, and fD(MR), with the median values of 0.86, 0.85 and 0.85, respectively; corresponding inter-quartile range (IQR) reached 9.6%, 10% and 10.2%. For the CC analysis, the best three strategies were fD(MR)-LS, D-MR-LS and D-MR with the median values of 0.97, 0.96 and 0.94, respectively; corresponding IQR reached 11%; 9% and 15%. Concerning the time-sequence analysis, the anti-chronological registration (all deformable strategies pooled) showed a better median DSI value (0.84 vs 0.83, p < 0.001) and IQR (11.2% vs 12.4%). For CC, the anti-chronological registration (all deformable strategies pooled) had a slightly lower median value (0.91 vs 0.912, p < 0.001) but a better IQR (16.4% vs 21%). Conclusions: The use of fD(MR)-LS is a good registration strategy for HN-ART as it is the best compromise in terms of median and IQR for both DSI and CC. Even though less robust in terms of CC, D-MR is a good alternative. None of the time-sequence appears superior. (C) 2008 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 89 (2008) 1-12.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 50 条
  • [21] Comparison of Deformable Versus Rigid PET/CT Registration in Head-and-Neck Cancer (HNC) Patients Undergoing Postoperative Radiation Therapy (PORT)
    Kovalchuk, N.
    Niedermayr, T. R.
    Qureshi, M. M.
    Willins, J.
    Truong, M. T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S511 - S512
  • [22] Radiation dose response simulation for biomechanical-based deformable image registration of head and neck cancer treatment
    Al-Mayah, Adil
    Moseley, Joanne
    Hunter, Shannon
    Brock, Kristy
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (21): : 8481 - 8489
  • [23] Evaluation of deformable image registration methods for dose monitoring in head and neck adaptive radiotherapy
    Rigaud, B.
    Simon, A.
    Castelli, J.
    Gobeli, M.
    Arango, J. D. Ospina
    Cazoulat, G.
    Henry, O.
    Haigron, P.
    De Crevoisier, R.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S488 - S489
  • [24] DOSIMETRIC ANALYSIS OF WEEKLY ADAPTIVE HEAD & NECK IMRT USING A DEFORMABLE REGISTRATION ALGORITHM
    Gagnon, P.
    Tanyi, J.
    Ku, L. C.
    McDonald, T.
    Holland, J.
    Fuss, M.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S28 - S28
  • [25] EVALUATION OF DEFORMABLE IMAGE CO-REGISTRATION IN ADAPTIVE IMRT FOR HEAD AND NECK CANCER
    Olteanu, A. M. L.
    Madani, I.
    De Gersem, W.
    Vercauteren, T.
    De Neve, W.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S443 - S444
  • [26] Quantitative deformable image registration uncertainty framework for proton head and neck treatment
    Amstutz, F.
    D'Almeida, P. G.
    Wu, X.
    Albertini, F.
    Bachtiary, B.
    Weber, D. C.
    Unkelbach, J.
    Lomax, A. J.
    Zhang, Y.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S340 - S342
  • [27] Deformable versus rigid registration of PET/CT images for radiation treatment planning of head and neck and lung cancer patients: a retrospective dosimetric comparison
    Dominique Fortin
    Parminder S Basran
    Tanya Berrang
    David Peterson
    Elaine S Wai
    Radiation Oncology, 9
  • [28] Deformable versus rigid registration of PET/CT images for radiation treatment planning of head and neck and lung cancer patients: a retrospective dosimetric comparison
    Fortin, Dominique
    Basran, Parminder S.
    Berrang, Tanya
    Peterson, David
    Wai, Elaine S.
    RADIATION ONCOLOGY, 2014, 9
  • [29] RADIATION-THERAPY FOR NONSQUAMOUS TUMORS OF THE HEAD AND NECK
    MANTRAVADI, RVP
    OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 1986, 19 (04) : 741 - 754
  • [30] Erythropoietin in radiation therapy. Tumors of the head and neck
    Dunst, J.
    Metzen, E.
    Rades, D.
    ONKOLOGE, 2007, 13 (02): : 143 - +