Comparison of the BTE tech EVJ handgrip to the Jamar hand dynamometer for measuring grip strength

被引:1
|
作者
Myers, Edwin J. [1 ]
Dominguez, David S. [1 ]
Guigliano, Melissa E. [1 ]
Mallory, Melissa G. [1 ]
机构
[1] Florida Gulf Coast Univ, Marieb Coll Hlth & Human Serv, Dept Rehabil Sci, Occupat Therapy Program, Ft Myers, FL 33965 USA
关键词
Dynamometer; industrial rehabilitation; hand function; grip strength; functional capacity evaluation;
D O I
10.3233/TAD-200318
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
INTRODUCTION: This study compared the inter-instrument reliability of the Jamar Hand Dynamometer (Jamar) to the BTE EVJ Handgrip tool (EVJ). The EVJ is a new digital handgrip instrument designed by BTE Technologies Inc. (BTE Tech) utilizing Bluetooth technology to automatically upload data to a computer or electronic health record. METHOD: This repeated measure study engaged 338 participants (N = 199 females, N = 139 males) ages 20 to 50. All participants were tested on both devices following the protocol established by the American Society of Hand Therapists (ASHT). RESULTS: Comparative statistics included ICC values (0.81-0.84), Pearson R (correlation coefficient) (0.68-0.77), and Bland Altman plots (93-95% of data within 2 SD), indicating good inter-instrument agreement. CONCLUSIONS: The EVJ Handgrip, developed by BTE Technologies, demonstrated good inter-instrument reliability with the Jamar Hand Dynamometer and may be reliable to use when referencing the published normative values in the clinical environment.
引用
收藏
页码:221 / 227
页数:7
相关论文
共 50 条
  • [21] A comparative study of the Jamar® and the Grippit® for measuring handgrip strength in clinical practice
    Svantesson, Ulla
    Norde, Maria
    Svensson, Sandra
    Brodin, Elisabeth
    ISOKINETICS AND EXERCISE SCIENCE, 2009, 17 (02) : 85 - 91
  • [22] Reliability and validity of an electronic dynamometer for measuring grip strength
    Allen, Deborah
    Barnett, Fiona
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2011, 18 (05): : 258 - 264
  • [23] Conversion of grip strength scores between Jamar dynamometer and a modified sphygmomanometer in patients with rheumatoid arthritis
    Ugurlu, U.
    Ozdogan, H.
    ISOKINETICS AND EXERCISE SCIENCE, 2013, 21 (04) : 263 - 272
  • [24] GRIP STRENGTH AND HAND POSITION OF THE DYNAMOMETER IN 204 FINNISH ADULTS
    HARKONEN, R
    PIIRTOMAA, M
    ALARANTA, H
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1993, 18B (01): : 129 - 132
  • [25] EFFECT OF VARIATIONS IN HAND GRIP ON RECORDED DYNAMOMETER BACK STRENGTH
    HINOJOSA, R
    BERGER, RA
    RESEARCH QUARTERLY, 1965, 36 (03): : 366 - 367
  • [26] Reference values for adult grip strength measured with a Jamar dynamometer: a descriptive meta-analysis
    Bohannon, RW
    Peolsson, A
    Massy-Westropp, N
    Desrosiers, J
    Bear-Lehman, JB
    PHYSIOTHERAPY, 2006, 92 (01) : 11 - 15
  • [27] GRIP-STRENGTH MEASUREMENT - A COMPARISON OF 3 JAMAR DYNAMOMETERS
    FLOODJOY, M
    MATHIOWETZ, V
    OCCUPATIONAL THERAPY JOURNAL OF RESEARCH, 1987, 7 (04): : 235 - 243
  • [28] COMPARISON BETWEEN CAMRY AND JAMAR DYNAMOMETERS IN MEASURING HAND GRIP STRENGTH AMONG OLDER POST-ACUTE COVID-19 OUTPATIENTS
    Tai, M. H.
    Wan, S. N.
    Engkasan, J.
    Ong, T.
    AGE AND AGEING, 2022, 51 (SUPPL 2)
  • [29] Reliability and validity of an electronic dynamometer for measuring grip strength COMMENT
    Fitinghoff, Helene
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2011, 18 (05): : 265 - 265
  • [30] Relationship between hand size, grip strength and dynamometer position in women
    Fiebert, IM
    Roach, KE
    Fromdahl, JW
    Moyer, JD
    Pfeiffer, FF
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 1998, 10 (03) : 137 - 142