Effect of apertures in ultrasound-modulated optical tomography with photomultiplier tube

被引:4
|
作者
Zhu, Lili [1 ]
Ran, Shubing [1 ]
Lin, Zhiyuan [1 ]
Li, Hui [1 ]
机构
[1] Fujian Normal Univ, Coll Photon & Elect Engn, Key Lab Optoelect Sci & Technol Med, Minist Educ,Fujian Prov Key Lab Photon Technol, Fuzhou 350007, Fujian, Peoples R China
关键词
ultrasound-modulated light; modulation depth; aperture; photomultiplier tube;
D O I
10.1117/12.999559
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Improving signal to noise ratio in ultrasound-modulated optical tomography (UOT) is a research topic. Laying apertures in front of a photomultiplier tube (PMT) can reduce the ambient noise collected by the PMT, and efficiently improve the signal to noise ratio of UOT. In addition, the effective area of detection and the off-axis position of the PMT would be varied by changing the aperture size and position in front of the PMT. Experimental results indicated that ultrasound-modulated signal is dependent on the area of detection. The greater the detector area, the smaller the ultrasound-modulated signal and its modulation depth. The modulated signal also depended on the off-axis position of the PMT from the optic axis. In particular, the modulated signal did not reach the biggest value when the PMT just placed on the optics axis. Choosing appropriate size, position of aperture, can improve the signal to noise ratio and image contrast.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Methods for parallel-detection-based ultrasound-modulated optical tomography
    Li, J
    Wang, LV
    [J]. APPLIED OPTICS, 2002, 41 (10) : 2079 - 2084
  • [42] Camera-based ultrasound-modulated optical tomography with isometric resolution
    Lin, Guangzhong
    Wu, Daixuan
    Zhao, Jiayu
    Xu, Yiyun
    Shen, Yuecheng
    Shao, Lijie
    [J]. APPLIED PHYSICS LETTERS, 2024, 124 (25)
  • [43] Study of ultrasound-modulated optical tomography in biological tissue with parallel detection
    Yao, G
    Wang, LHV
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2317 - 2320
  • [44] AM ultrasound-modulated optical tomography with real-time FFT
    Yao, Y
    Xing, D
    He, YH
    [J]. CHINESE SCIENCE BULLETIN, 2001, 46 (22): : 1869 - 1872
  • [45] Quantitative reconstruction of absorption and scattering coefficients in ultrasound-modulated optical tomography
    Powell, Samuel
    Leung, Terence S.
    [J]. PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2014, 2014, 8943
  • [46] Ultrasound-modulated light tomography assessment of osteoporosis
    Lev, A
    Rubanov, E
    Sfez, B
    Shany, S
    Foldes, AJ
    [J]. OPTICS LETTERS, 2005, 30 (13) : 1692 - 1694
  • [47] Effects of modulation phase of ultrasound-modulated light on the ultrasound-modulated optical image in turbid media
    Weng, Cuncheng
    Zhang, Jing
    [J]. ULTRASONICS, 2012, 52 (04) : 472 - 474
  • [48] Imaging by optically scattering objects and absorption objects with ultrasound-modulated optical tomography
    Fujian Provincial Key Laboratory of Photonic Technology, College of Photonic and Electronic Engineering, Fujian Normal University, Fuzhou
    Fujian
    350007, China
    [J]. Zhongguo Jiguang, 2
  • [49] Ultrasound-modulated optical tomography of biological tissue by use of contrast of laser speckles
    Li, Jun
    Ku, Geng
    Wang, Lihong V.
    [J]. Applied Optics, 2002, 41 (28): : 6030 - 6035
  • [50] Ultrasound-modulated optical tomography of biological tissue by use of contrast of laser speckles
    Li, J
    Ku, G
    Wang, LHV
    [J]. APPLIED OPTICS, 2002, 41 (28) : 6030 - 6035