Effect of apertures in ultrasound-modulated optical tomography with photomultiplier tube

被引:4
|
作者
Zhu, Lili [1 ]
Ran, Shubing [1 ]
Lin, Zhiyuan [1 ]
Li, Hui [1 ]
机构
[1] Fujian Normal Univ, Coll Photon & Elect Engn, Key Lab Optoelect Sci & Technol Med, Minist Educ,Fujian Prov Key Lab Photon Technol, Fuzhou 350007, Fujian, Peoples R China
关键词
ultrasound-modulated light; modulation depth; aperture; photomultiplier tube;
D O I
10.1117/12.999559
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Improving signal to noise ratio in ultrasound-modulated optical tomography (UOT) is a research topic. Laying apertures in front of a photomultiplier tube (PMT) can reduce the ambient noise collected by the PMT, and efficiently improve the signal to noise ratio of UOT. In addition, the effective area of detection and the off-axis position of the PMT would be varied by changing the aperture size and position in front of the PMT. Experimental results indicated that ultrasound-modulated signal is dependent on the area of detection. The greater the detector area, the smaller the ultrasound-modulated signal and its modulation depth. The modulated signal also depended on the off-axis position of the PMT from the optic axis. In particular, the modulated signal did not reach the biggest value when the PMT just placed on the optics axis. Choosing appropriate size, position of aperture, can improve the signal to noise ratio and image contrast.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Structured ultrasound-modulated optical tomography
    Bocoum, Maimouna
    Gennisson, Jean-Luc
    Laudereau, Jean-Baptiste
    Louchet-Chauvet, Anne
    Tualle, Jean-Michel
    Ramaz, Francois
    [J]. APPLIED OPTICS, 2019, 58 (08) : 1933 - 1940
  • [2] Chirped ultrasound-modulated optical tomography
    Ku, G
    Yao, G
    Wang, LHV
    [J]. OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE III, PROCEEDINGS OF, 1999, 3597 : 371 - 375
  • [3] Optical phantoms for ultrasound-modulated optical tomography
    Kim, Chulhong
    Garcia-Uribe, Alejandro
    Kothapalli, Sri-Rajasekhar
    Wang, Lihong V.
    [J]. DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENTS OF TISSUE, 2008, 6870
  • [4] Simulation study of ultrasound-modulated optical tomography
    Yao, G
    Wang, LHV
    [J]. BIOMEDICAL OPTOACOUSTICS II, 2001, 4256 : 192 - 199
  • [5] A new method of ultrasound-modulated optical tomography
    Yao, Y
    Xing, D
    He, YH
    Ueda, K
    [J]. BIOMEDICAL PHOTONICS AND OPTOELECTRONIC IMAGING, 2000, 4224 : 218 - 222
  • [6] Ultrasound-modulated optical tomography at new depth
    Lai, Puxiang
    Xu, Xiao
    Wang, Lihong V.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (06)
  • [7] Image reconstruction in ultrasound-modulated optical tomography
    Li, J
    Wang, LHV
    [J]. PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING, 2004, 5320 : 268 - 272
  • [8] Local inversions in ultrasound-modulated optical tomography
    Bal, Guillaume
    Moskow, Shari
    [J]. INVERSE PROBLEMS, 2014, 30 (02)
  • [9] Ultrasound-modulated optical tomography in the reflective and coaxial configuration
    Fu, HB
    Xing, D
    Zeng, YG
    Wang, Y
    [J]. ALT'03 INTERNATIONAL CONFERENCE ON ADVANCED LASER TECHNOLOGIES: BIOMEDICAL OPTICS, 2003, 5486 : 61 - 66
  • [10] Ultrasound-modulated bioluminescence tomography
    Bal, Guillaume
    Schotland, John C.
    [J]. PHYSICAL REVIEW E, 2014, 89 (03):