SINGLE TUBE REAL TIME PCR FOR DETECTION OF STREPTOCOCCUS PNEUMONIAE, MYCOPLASMA PNEUMONIAE, CHLAMYDOPHILA PNEUMONIAE AND LEGIONELLA PNEUMOPHILA FROM CLINICAL SAMPLES OF CAP

被引:18
|
作者
Nomanpour, Bizhan [1 ]
Ghodousi, Arash [1 ]
Babaei, Toraj [2 ]
Jafari, Siroos [3 ]
Feizabadi, Mohammad Mehdi [1 ,4 ]
机构
[1] Univ Tehran Med Sci, Sch Med, Dept Microbiol, Tehran, Iran
[2] Shaheed Rajaie Cardiovasc Med & Res Ctr, Dept Cardiac Anesthesiol, Tehran, Iran
[3] Univ Tehran Med Sci, Sch Med, Dept Infect Dis, Tehran, Iran
[4] Univ Tehran Med Sci, Pediat Infect Dis Res Ctr, Tehran, Iran
关键词
community acquired pneumonia; CAP; real time PCR; Streptococcus pneumoniae; Legionella pneumophila; Chlamydophila pneumoniae; Mycoplasma pneumoniae; COMMUNITY-ACQUIRED PNEUMONIA; INFECTIOUS-DISEASES-SOCIETY; PATHOGENS; ASSAY; SPP; DNA;
D O I
10.1556/AMicr.59.2012.2.3
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
We designed a multiplex real time PCR for rapid, sensitive and specific detection of Streptococcus pneumoniae, Legionella pneumophila, Chlamydophila pneumoniae and Mycoplasma pneumoniae. The study cases consisted of 129 patients with community acquired pneumonia (CAP). Bacteriological techniques were implemented for detection of the cultivable organisms. DNA were extracted from sputa, throat swabs, bronchoalveolar lavages and tracheal aspirates and used as templates in real time PCR. The primers and probes were designed for cbpA (S. pneumoniae), p1adhesin (M. pneumoniae), mip (L. pneumophila) and ompA (C. pneumoniae). After optimization of real time PCR for every organism, the experiments were continued in multiplex in a single tube. Of 129 CAP specimens, the positive cultures included 14 (10.85%) for S. pneumoniae, 9 (6.98%) for L. pneumophila and 3 (2.33%) for M. pneumoniae. Four specimens (3.10%) were positive for C. pneumoniae by real time PCR. The sensitivity of our real time PCR was 100% for all selected bacteria. The specificity of the test was 98.26%, 98.34%, 100% and 100% for S. pneumoniae, L. pneumophila, M. pneumoniae and C. pneumoniae, respectively. This is the first report on the use of multiplex real time PCR for detection of CAP patients in the Middle East. The method covers more than 90% of the bacterial pathogens causing CAP.
引用
收藏
页码:171 / 184
页数:14
相关论文
共 50 条
  • [21] DETECTION OF STREPTOCOCCUS-PNEUMONIAE IN SPUTUM SAMPLES BY PCR
    GILLESPIE, SH
    ULLMAN, C
    SMITH, MD
    EMERY, V
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (05) : 1308 - 1311
  • [22] Development of real-time multiplex nucleic acid sequence-based amplification for detection of Mycoplasma pneumoniae, Chlamydophila pneumoniae, and Legionella spp. in respiratory specimens
    Loens, K.
    Beck, T.
    Ursi, D.
    Overdijk, M.
    Sillekens, P.
    Goossens, H.
    Ieven, M.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (01) : 185 - 191
  • [23] Duplex real-time PCR assay for detection of Streptococcus pneumoniae in clinical samples and determination of penicillin susceptibility
    Harris, Kathryn A.
    Turner, Paul
    Green, Elaine A.
    Hartley, John C.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (08) : 2751 - 2758
  • [24] Real-time PCR assays for the detection and quantification of Streptococcus pneumoniae
    Park, Hee Kuk
    Lee, Hee Jung
    Kim, Wonyong
    [J]. FEMS MICROBIOLOGY LETTERS, 2010, 310 (01) : 48 - 53
  • [25] In vitro activity of levofloxacin against contemporary clinical isolates of Legionella pneumophila, Mycoplasma pneumoniae and Chlamydia pneumoniae from North America and Europe
    Critchley, IA
    Jones, ME
    Heinze, PD
    Hubbard, D
    Engler, HD
    Evangelista, AT
    Thornsberry, C
    Karlowsky, JA
    Sahm, DF
    [J]. CLINICAL MICROBIOLOGY AND INFECTION, 2002, 8 (04) : 214 - 221
  • [26] Evaluation of the NucliSens miniMAG RNA extraction and real-time NASBA applications for the detection of Mycoplasma pneumoniae and Chlamydophila pneumoniae in throat swabs
    Loens, K.
    Ursi, D.
    Goossens, H.
    Leven, M.
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2008, 72 (02) : 217 - 219
  • [27] Evaluation of two commercial tests for detection of Legionella pneumophila and Mycoplasma pneumoniae (Duplica, Euroclone) in clinical specimens
    Lueck, C.
    Helbig, J. H.
    Hochauf, K.
    Jacobs, E.
    Dumke, R.
    [J]. INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2009, 299 : 40 - 40
  • [28] Evaluation of a New Real-time PCR Assay for Detection of Mycoplasma Pneumoniae in Clinical Specimens
    Zhao Fei
    Cao Bin
    He Li Hua
    Yin Yu Dong
    Tao Xiao Xia
    Song Shu Fan
    Meng Fan Liang
    Zhang Jian Zhong
    [J]. BIOMEDICAL AND ENVIRONMENTAL SCIENCES, 2012, 25 (01) : 77 - 81
  • [30] Verification of the ProPneumo-1 assay for the simultaneous detection of Mycoplasma pneumoniae and Chlamydophila pneumoniae in clinical respiratory specimens
    Higgins, Rachel R.
    Lombos, Ernesto
    Tang, Patrick
    Rohoman, Karl
    Maki, Anne
    Brown, Shirley
    Jamieson, Frances
    Drews, Steven J.
    [J]. ANNALS OF CLINICAL MICROBIOLOGY AND ANTIMICROBIALS, 2009, 8