Ultra-thin-polysiloxane-film-composite membranes for the optimisation of amperometric oxidase enzyme electrodes

被引:23
|
作者
Myler, S
Collyer, SD
Bridge, KA
Higson, SPJ
机构
[1] Univ Manchester, Manchester Mat Sci Ctr, Manchester M1 7HS, Lancs, England
[2] Univ Manchester, Manchester M1 7HS, Lancs, England
来源
BIOSENSORS & BIOELECTRONICS | 2002年 / 17卷 / 1-2期
基金
英国工程与自然科学研究理事会;
关键词
ultra-thin film composite membranes; blood glucose determinations; polysiloxane; permselectivity; biocompatibility;
D O I
10.1016/S0956-5663(01)00265-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An outer ultra-thin-polydimethyldichlorosiloxane film composite membrane has been used as the outer covering barrier in an amperometric glucose oxidase enzyme electrode biosensor. The composite membrane was formed via the condensation polymerisation of dimethyldichlorosilane at the surface of a host porous alumina membrane. Homogeneous polydimethyldichlorosiloxane films of < 100 nm thickness acted as effective substrate diffusional barriers and were supported by the underlying porous alumina surface. Glucose and oxygen permeability coefficients were determined using diffusion chamber apparatus. Polysiloxane composite membranes were found to offer some screening functionality towards anionic biological interferents such as ascorbate. On exposure to blood an approximate 25% signal drift was observed during the first 2 h exposure to blood; after this time responses remained almost stable. Whole blood glucose determinations showed a close correlation (r(2) = 0.98) to analyses performed via standard hospital analyses. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:35 / 43
页数:9
相关论文
共 50 条
  • [1] Poly(o-phenylenediamine) ultra-thin polymer-film composite membranes for enzyme electrodes
    Myler, S
    Eaton, S
    Higson, SPJ
    [J]. ANALYTICA CHIMICA ACTA, 1997, 357 (1-2) : 55 - 61
  • [2] Amperometric multidetection with composite enzyme electrodes
    de Prada, AGV
    Peña, N
    Parrado, C
    Reviejo, AJ
    Pingarrón, JM
    [J]. TALANTA, 2004, 62 (05) : 896 - 903
  • [3] AMPEROMETRIC ENZYME ELECTRODES .3. ALCOHOL OXIDASE
    GUILBAULT, GG
    LUBRANO, GJ
    [J]. ANALYTICA CHIMICA ACTA, 1974, 69 (01) : 189 - 194
  • [4] AMPEROMETRIC ENZYME ELECTRODES FOR SUBSTRATES OF IMMOBILIZED PYRANOSE OXIDASE
    PETRIVALSKY, M
    SKLADAL, P
    MACHOLAN, L
    VOLC, J
    [J]. COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1994, 59 (05) : 1226 - 1244
  • [5] Amperometric Noise at Thin Film Band Electrodes
    Larsen, Simon T.
    Heien, Michael L.
    Taboryski, Rafael
    [J]. ANALYTICAL CHEMISTRY, 2012, 84 (18) : 7744 - 7749
  • [6] Mathematical modeling in amperometric oxidase enzyme-membrane electrodes
    Loghambal, S.
    Rajendran, L.
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2011, 373 (1-2) : 20 - 28
  • [7] Computational modelling of amperometric enzyme electrodes with selective and perforated membranes
    Baronas, Romas
    Ivanauskas, Feliksas
    Kulys, Juozas
    [J]. COMPUTATION IN MODERN SCIENCE AND ENGINEERING VOL 2, PTS A AND B, 2007, 2 : 457 - +
  • [8] MATHEMATICAL-MODELING OF AMPEROMETRIC ENZYME ELECTRODES WITH PERFORATED MEMBRANES
    SCHULMEISTER, T
    PFEIFFER, D
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (02): : 75 - 79
  • [9] AMPEROMETRIC ENZYME ELECTRODES .2. AMINO-ACID OXIDASE
    GUILBAULT, GG
    LUBRANO, GJ
    [J]. ANALYTICA CHIMICA ACTA, 1974, 69 (01) : 183 - 188
  • [10] A permselective biotinylated polydicarbazole film for the fabrication of amperometric enzyme electrodes
    Cosnier, S
    Le Pellec, A
    Marks, RS
    Périé, K
    Lellouche, JP
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2003, 5 (11) : 973 - 977