Comparison of short-term light disturbance, optical and visual performance outcomes between a myopia control contact lens and a single-vision contact lens

被引:25
|
作者
Vicente Garcia-Marques, Jose [1 ]
Juliana Macedo-De-Araujo, Rute [2 ]
Cervino, Alejandro [1 ]
Garcia-Lazaro, Santiago [1 ]
McAlinden, Colm [3 ,4 ]
Manuel Gonzalez-Meijome, Jose [2 ]
机构
[1] Univ Valencia, Dept Opt & Optometry & Vis Sci, Optometry Res Grp, Valencia, Spain
[2] Univ Minho, Ctr Phys Optometry, Sch Sci, Clin & Expt Optometry Res Lab CEORLab, Braga, Portugal
[3] Swansea Bay Univ Hlth Board, Singleton Hosp, Dept Ophthalmol, Swansea, W Glam, Wales
[4] Wenzhou Med Univ, Wenzhou, Peoples R China
关键词
light disturbance; MiSight; multifocal contact lens; myopia control; visual performance; visual quality; MISIGHT ASSESSMENT; SENSITIVITY; QUALITY; PROGRESSION; SPAIN; GLARE;
D O I
10.1111/opo.12729
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To compare the optical and visual performance of a dual-focus (DF) contact lens used for myopia control with a single-vision (SV) contact lens of the same material. Methods A randomised, double-masked crossover study. Twenty-eight healthy, myopic volunteers between 18 and 32 years of age (23.49 +/- 4.07 years) participated in this study. The sensory dominant eye for distance vision was determined. Refraction, best-corrected visual acuity (VA) and aberrations for 3 mm and 5 mm pupil diameters were quantified without a contact lens in situ. Subjects were fitted with two contact lens designs: DF and SV, both made of omafilcon A material. The Quality of Vision (QoV) questionnaire, over-refraction, best-corrected VA, stereopsis at 40 cm, best-corrected photopic and mesopic contrast sensitivity, light disturbance and aberrations were assessed 25 min after contact lens insertion. Results There were no statistically significant differences in best-corrected VA and stereopsis between the baseline, DF and SV conditions. Photopic and mesopic contrast sensitivity were lower for the DF contact lens at all frequencies, with the exception of the mesopic contrast sensitivity at 18 cycles per degree (p = 0.23). Higher order aberrations and light disturbance size and irregularity were higher for the DF contact lens (p < 0.001). No differences were found in higher order aberrations between baseline and the SV contact lens condition for each pupil diameter. QoV scores also revealed lower frequency, severity and bothersome scores with the SV contact lens than with the DF contact lens (p < 0.001). Conclusions The DF contact lens design decreased the psychophysical and psychometric visual quality scores in the short-term under dim-light conditions when compared with a single-vision contact lens design of the same material. VA and stereopsis were unaffected by the lens design.
引用
收藏
页码:718 / 727
页数:10
相关论文
共 23 条
  • [21] The short-term effects of PMMA contact lens wear on keratometric behaviour: results for a single keratoconic cornea
    Chetty, E.
    Gillan, W. D. H.
    [J]. AFRICAN VISION AND EYE HEALTH JOURNAL, 2010, 69 (02): : 69 - 76
  • [22] SHORT-TERM, LOW-CONTRAST VISUAL-ACUITY REDUCTION ASSOCIATED WITH INVIVO CONTACT-LENS DRYING
    TIMBERLAKE, GT
    DOANE, MG
    BERTERA, JH
    [J]. OPTOMETRY AND VISION SCIENCE, 1992, 69 (10) : 755 - 760
  • [23] Exploring non-adherence to contact lens wear schedule: Subjective assessments and patient related factors in children wearing single vision and myopia control contact lenses
    Weng, Rebecca
    Naduvilath, Thomas
    Philip, Krupa
    Chen, Xiang
    Sankaridurg, Padmaja
    [J]. CONTACT LENS & ANTERIOR EYE, 2021, 44 (01): : 94 - 101