Arthroscopically assisted and three-dimensionally modeled minimally invasive rim plate osteosynthesis via modified anterolateral approach for posterolateral tibial plateau fractures

被引:14
|
作者
Delcogliano, Marco [1 ]
Marin, Roberto [1 ,2 ]
Deabate, Luca [1 ]
Previtali, Davide [1 ]
Filardo, Giuseppe [1 ,3 ]
Surace, Michele Francesco [2 ]
Candrian, Christian [1 ]
Gaffurini, Paolo [1 ]
机构
[1] Osped Reg Lugano, EOC, Orthopaed & Traumatol Unit, Lugano, Switzerland
[2] Univ Insubria, Interdisciplinary Res Ctr Pathol & Surg Musculosk, Dept Biotechnol & Life Sci DBSV, Varese, Italy
[3] IRCCS Ist Ortoped Rizzoli, ATRC, Bologna, Italy
来源
KNEE | 2020年 / 27卷 / 03期
关键词
Posterolateral tibial plateau fracture; Anterolateral approach; Mini-invasive plate osteosynthesis; 3D fracture model; MORPHOLOGICAL-CHARACTERISTICS; FRAGMENTS; DEPRESSION; MANAGEMENT; FIXATION; INJURY;
D O I
10.1016/j.knee.2020.02.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim: The aim of this study was to describe a new, closed, arthroscopically-assisted reduction of posterolateral tibial plateau fractures with minimally invasive plate osteosynthesis using a plate pre-contoured over a 3D-model based on a CT-scan of the injured tibial plateau and positioned by using a minimal anterolateral approach. Methods: A five to six centimeter long curvilinear incision was made over the Gerdy's tubercle. After subcutaneous dissection, the fascia was incised, the ileo-tibial band was split, and the dissection was extended posteriorly. The knee was flexed to 90 degrees and the space between the fibular collateral ligament and the posterolateral plateau rim (para-FCL space) was created. A variable-angle locking compression plate contoured on a 3D-model was inserted flush to the tibial plateau rim. Two cortical screws were placed to ensure support under the area of depression as far posteriorly as possible. Two additional screws were implanted, and a cortical screw was used for the most anterior screw hole. The custom pre-contoured plate based on a person-specific 3D-model, associated with arthroscopy reduction, provides a supporting and containing effect to the posterolateral periarticular fragments and allows a minimally invasive plate osteosynthesis fixation to be performed. This guarantees a proper reduction and fixation without the described limitations and risks associated with the classic approaches. Conclusions: This approach should be considered to treat fractures of the posterolateral plateau, isolated or associated with medial tibial plateau fractures, as it could improve the outcome in terms of lower associated risks, better reduction and fixation, and faster and improved patient recovery. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:1093 / 1100
页数:8
相关论文
共 42 条
  • [21] Minimally invasive plate osteosynthesis of distal tibial fracture using a posterolateral approach: a cadaveric study and preliminary report
    Yashwant Singh Tanwar
    Masood Habib
    Atin Jaiswal
    Satyaprakash Singh
    International Orthopaedics, 2013, 37 : 989 - 990
  • [22] Minimally invasive plate osteosynthesis of distal tibial fracture using a posterolateral approach: a cadaveric study and preliminary report
    Apipop Kritsaneephaiboon
    Tanawat Vaseenon
    Boonsin Tangtrakulwanich
    International Orthopaedics, 2013, 37 : 105 - 111
  • [23] Management of feline tibial diaphyseal fractures using orthogonal plates performed via minimally invasive plate osteosynthesis
    Craig, Andrew
    Witte, Philip G.
    Moody, Tristram
    Harris, Karen
    Scott, Harry W.
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2018, 20 (01) : 6 - 14
  • [24] Minimally invasive plate osteosynthesis of acetabular anterior column fractures using the two-incision minimally invasive approach and a preshaped three dimension plate
    Yan Zhuang
    Shenglu Cao
    Yanbin Lin
    Renbin Li
    Gang Wang
    Yiran Wang
    International Orthopaedics, 2016, 40 : 2157 - 2162
  • [25] Minimally invasive plate osteosynthesis of acetabular anterior column fractures using the two-incision minimally invasive approach and a preshaped three dimension plate
    Zhuang, Yan
    Cao, Shenglu
    Lin, Yanbin
    Li, Renbin
    Wang, Gang
    Wang, Yiran
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (10) : 2157 - 2162
  • [26] An imageology-based feasibility study of plating posterolateral tibial plateau fractures via an anterolateral trans-fibular-head approach
    Zhou, Xiaoji
    Zhou, Jiangshan
    Qian, Huajun
    Qian, Chunxiao
    Xu, Bin
    Pan, Lv
    Chu, Xudong
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [27] An imageology-based feasibility study of plating posterolateral tibial plateau fractures via an anterolateral trans-fibular-head approach
    Xiaoji Zhou
    Jiangshan Zhou
    Huajun Qian
    Chunxiao Qian
    Bin Xu
    Lv Pan
    Xudong Chu
    BMC Musculoskeletal Disorders, 25
  • [28] Clinical and radiological outcome of Gustilo type III open distal tibial and tibial shaft fractures after staged treatment with posterolateral minimally invasive plate osteosynthesis (MIPO) technique
    He, Xiaojian
    Hu, Chuanzhen
    Zhou, Kaihua
    Zhai, Qilin
    Wen, Weifeng
    Pan, Fugen
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (08) : 1097 - 1102
  • [29] Clinical and radiological outcome of Gustilo type III open distal tibial and tibial shaft fractures after staged treatment with posterolateral minimally invasive plate osteosynthesis (MIPO) technique
    Xiaojian He
    Chuanzhen Hu
    Kaihua Zhou
    Qilin Zhai
    Weifeng Wen
    Fugen Pan
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 1097 - 1102
  • [30] Comment on Kritsaneephaiboon et al.: Minimally invasive plate osteosynthesis of distal tibial fracture using a posterolateral approach: a cadaveric study and preliminary report
    Bing Li
    Da-wei Chen
    Guang-rong Yu
    Yun-feng Yang
    International Orthopaedics, 2013, 37 : 1423 - 1423