The effect of fresh gas flow rate and type of anesthesia machine on time to reach target sevoflurane concentration

被引:2
|
作者
Shin, Hye Won [1 ]
Yu, Hae Na [1 ]
Bae, Go Eun [1 ]
Huh, Hyub [1 ]
Park, Ji Yong [1 ]
Kim, Ji Young [1 ]
机构
[1] Korea Univ, Dept Anesthesiol & Pain Med, Anam Hosp, Coll Med, Inchon Ro 73, Seoul 02841, South Korea
来源
BMC Anesthesiology | 2017年 / 17卷
关键词
Inhalation anesthetics; Equipment design; Ventilation; CONSUMPTION; MANAGEMENT; DEVICES; SYSTEM;
D O I
10.1186/s12871-016-0294-y
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Anesthesia machines have been developed by the application of new technology for rapid and easier control of anesthetic concentration. In this study, we used a test lung to investigate whether the time taken to reach the target sevoflurane concentration varies with the rate of fresh gas flow (FGF) and type of anesthesia machine (AM). Methods: We measured the times taken to reach the target sevoflurane concentration (2 minimum alveolar concentration = 4%) at variable rates of FGF (0.5, 1, or 3 L/min) and different types of AM (Primus (R), Perseus (R), and Zeus (R) [Zeus (R) -F; Zeus (R) fresh gas mode, Zeus (R) -A; Zeus (R) auto-mode]). Concomitant ventilation was supplied using 100% O-2. The AMs were connected to a test lung. A sevoflurane vaporizer setting of 6% was used in Primus (R), Perseus (R), and Zeus (R) -F; a target end-tidal setting of 4% was used in Zeus (R) -A (from a vaporizer setting of 0%). The time taken to reach the target concentration was measured in every group. Results: When the same AM was used (Primus (R), Perseus (R), or Zeus (R) -F), the times to target concentration shortened as the FGF rate increased (P<0.05). Conversely, when the same FGF rate was used, but with different AMs, the time to target concentration was shortest in Perseus (R), followed by Primus (R), and finally by Zeus (R) -F (P<0.05). With regards to both modes of Zeus (R), at FGF rates of 0.5 and 1 L/min, the time to target concentration was shorter in Zeus (R) -A than in Zeus (R) -F; however, the time was longer in Zeus (R) -A than in Zeus (R) -F at FGF rate of 3 L/min (P<0.05). Conclusion: Shorter times taken to reach the target concentration were associated with high FGF rates, smaller internal volume of the AM, proximity of the fresh gas inlets to patients, absence of a decoupling system, and use of blower-driven ventilators in AM.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] An evaluation of the contributions by fresh gas flow rate, carbon dioxide concentration and desflurane partial pressure to carbon monoxide concentration during low fresh gas flows to a circle anaesthetic breathing system
    Fan, S. -Z.
    Lin, Y. -W.
    Chang, W. -S.
    Tang, C. -S.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2008, 25 (08) : 620 - 626
  • [22] Effect of concentration and gas flow rate on the removal of gas-phase trichloroethylene in a novel packed biofilter
    Baskaran D.
    Rajamanickam R.
    Vaidyalingam B.
    Bioresource Technology Reports, 2020, 9
  • [23] Effect of gas temperature on flow rate characteristics of an averaging pitot tube type flow meter
    Yeo, Seung Hwa
    Lee, Su Ryong
    Lee, Choong Hoon
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2015, 29 (01) : 241 - 249
  • [24] Effect of gas temperature on flow rate characteristics of an averaging pitot tube type flow meter
    Seung Hwa Yeo
    Su Ryong Lee
    Choong Hoon Lee
    Journal of Mechanical Science and Technology, 2015, 29 : 241 - 249
  • [25] Incidence of shivering in patients undergoing ambulatory gynecological laparoscopy increases by fresh gas flow rate and surgical time
    Panah, M
    Rosenblatt, M
    Kahn, P
    Bronheim, D
    ANESTHESIA AND ANALGESIA, 1997, 84 : S18 - S18
  • [26] Biofiltration of air contaminated by styrene: Effect of nitrogen supply, gas flow rate, and inlet concentration
    Jorio, H
    Bibeau, L
    Heitz, M
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (09) : 1764 - 1771
  • [27] Effect of Pulsed Corona Discharge Voltage and Feed Gas Flow Rate on Dissolved Ozone Concentration
    Prasetyaningrum, A.
    Ratnawati
    Jos, B.
    INTERNATIONAL CONFERENCE OF CHEMICAL AND MATERIAL ENGINEERING (ICCME) 2015: GREEN TECHNOLOGY FOR SUSTAINABLE CHEMICAL PRODUCTS AND PROCESSES, 2015, 1699
  • [28] A Novel, Cassette-Based Nitric Oxide Delivery System Accurately Delivers Inhaled Nitric Oxide via the Anesthesia Machine Independent of Fresh Gas Flow Rate and Volatile Anesthetic Agent
    Twite, Mark
    Anderson, Stephanie
    Roebuck, Aaron
    ANESTHESIA AND ANALGESIA, 2023, 136 : 73 - 73
  • [29] A Novel, Cassette-Based Nitric Oxide Delivery System Accurately Delivers Inhaled Nitric Oxide via the Anesthesia Machine Independent of Fresh Gas Flow Rate and Volatile Anesthetic Agent
    Twite, Mark
    Anderson, Stephanie
    Roebuck, Aaron
    ANESTHESIA AND ANALGESIA, 2023, 136 : 1000 - 1001
  • [30] Effect of Fresh Gas Flow Rate on Thiol/Disulphide Hemostasis and Ischemia-modified Albumin in Laparoscopic Cholecystectomy
    Eminoglu, Sermin
    Ozgunay, Seyda Efsun
    Karaca, Umran
    Demirel, Asiye
    Gamli, Mehmet
    Ustundag, Yasemin
    Karasu, Derya
    Eroglu, Hasan
    Erel, Ozcan
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2022, 32 (02): : 141 - 146