Optimally spaced fiber catheter for excimer laser coronary angioplasty (ELCA)

被引:0
|
作者
Lippincott, R [1 ]
Bellendir, J [1 ]
Taylor, K [1 ]
Reiser, C [1 ]
机构
[1] Spectranet Corp, Colorado Springs, CO 80907 USA
关键词
excimer; laser; catheter; optical fiber; angioplasty;
D O I
10.1117/12.350976
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Current multiple-optical-fiber catheters for excimer laser coronary angioplasty (ELCA) emit pulsed light at 308nm from a xenon chloride (XeCl) excimer laser to remove plaque in occluded arteries. Because the fiber ends, arranged in a closest-packed array, do not cover the entire surface of the catheter tip, these devices ablate holes typically holes typically 75-80% of the catheter tip diameter. To increase the ablation effectiveness, an optimally spaced fiber catheter has been designed in which the fiber-to-fiber spacing is increased precisely enough so as to cover the entire catheter tip area with fibers. In vitro and in vivo testing compared the optimally spaced catheter to catheter models currently in clinical use. Although device handling characteristics were found to be identical, the optimally spaced devices removed a significantly greater amount of tissue. This may offer a technical advantage in a clinical setting.
引用
收藏
页码:308 / 315
页数:8
相关论文
共 50 条
  • [21] CONTRIBUTION OF EXCIMER LASER TO CORONARY ANGIOPLASTY
    OLLIVIER, JP
    AVRILLIER, S
    ROUGIER, J
    RAYNAL, E
    GANDJBAKHCH, I
    BERTHIER, JP
    DRONIOU, J
    CABROL, C
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1988, 81 (03): : 261 - 267
  • [22] PERCUTANEOUS CORONARY EXCIMER LASER ANGIOPLASTY
    KARSCH, KR
    HAASE, KK
    MAUSER, M
    VOELKER, W
    BAUMBACH, A
    SEIPEL, L
    HERZ, 1990, 15 (04) : 233 - 240
  • [23] INVIVO EXCIMER LASER CORONARY ANGIOPLASTY
    OLLIVIER, JP
    AVRILLIER, S
    GANDJBAKHCH, I
    DRONIOU, J
    MEDECINE ET ARMEES, 1988, 16 (03): : 170 - 170
  • [24] PERCUTANEOUS EXCIMER LASER CORONARY ANGIOPLASTY
    LITVACK, F
    EIGLER, NL
    MARGOLIS, JR
    GRUNDFEST, WS
    ROTHBAUM, D
    LINNEMEIER, T
    HESTRIN, LB
    TSOI, D
    COOK, SL
    KRAUTHAMER, D
    GOLDENBERG, T
    LAUDENSLAGER, JR
    SEGALOWITZ, J
    FORRESTER, JS
    AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (15): : 1027 - 1032
  • [25] PERCUTANEOUS EXCIMER LASER CORONARY ANGIOPLASTY
    LITVACK, F
    GRUNDFEST, W
    EIGLER, N
    TSOI, D
    GOLDENBERG, T
    LAUDENSLAGER, J
    FORRESTER, J
    LANCET, 1989, 2 (8654): : 102 - 103
  • [26] DEVELOPMENT AND EVALUATION OF A FIBER OPTIC TIP LASER CATHETER FOR CORONARY ANGIOPLASTY
    DARGIER, C
    LEMAIRE, J
    FOURRIER, JL
    HERLEMONT, F
    MORDON, S
    BUYS, B
    BERNAGE, P
    BRUNETAUD, JM
    NIAY, P
    BERTRAND, ME
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1991, 84 (06): : 873 - 878
  • [27] LONG-TERM CLINICAL OUTCOME AND FACTORS ASSOCIATED WITH ADVERSE EVENTS AFTER SUCCESSFUL EXCIMER-LASER CORONARY ANGIOPLASTY (ELCA) - A REPORT FROM THE MULTICENTER ELCA REGISTRY
    KLEIN, LW
    EIGLER, N
    CUMMINS, F
    ROTHBAUM, D
    CIRCULATION, 1993, 88 (04) : 25 - 25
  • [28] CORONARY EXCIMER-LASER FOR UNSUCCESSFUL ANGIOPLASTY
    WAKSMAN, R
    CAREY, D
    GHAZZAL, ZMB
    KING, SB
    JOURNAL OF INVASIVE CARDIOLOGY, 1994, 6 (01): : 21 - 24
  • [29] ANGIOSCOPY AFTER CORONARY EXCIMER LASER ANGIOPLASTY
    DIETHRICH, EB
    HANAFY, HM
    SANTIAGO, OJ
    BAHADIR, I
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (02) : 643 - 643
  • [30] EARLY LIMITATIONS OF CORONARY EXCIMER LASER ANGIOPLASTY
    SANBORN, TA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (04) : 995 - 996