Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

被引:118
|
作者
Dournes, Gael [1 ,2 ]
Verdier, Damien [1 ,2 ]
Montaudon, Michel [1 ,2 ]
Bullier, Eric [3 ]
Riviere, Annalisa [3 ]
Dromer, Claire [4 ]
Picard, Francois [5 ]
Billes, Marc-Alain [6 ]
Corneloup, Olivier [1 ]
Laurent, Francois [1 ,2 ]
Lederlin, Mathieu [1 ,2 ]
机构
[1] Hop Haut Leveque, Dept Med Imaging, CHU Bordeaux, F-33600 Pessac, France
[2] Univ Bordeaux Segalen, F-33076 Bordeaux, France
[3] Hop Haut Leveque, CHU Bordeaux, Dept Nucl Med, F-33600 Pessac, France
[4] Hop Haut Leveque, CHU Bordeaux, Dept Resp Dis, F-33600 Pessac, France
[5] Hop Haut Leveque, CHU Bordeaux, Dept Cardiol, F-33600 Pessac, France
[6] Hop Haut Leveque, CHU Bordeaux, Dept Cardiac Surg, F-33600 Pessac, France
关键词
Dual energy CT; Dual energy lung perfusion imaging; Pulmonary scintigraphy; Pulmonary hypertension; Chronic thromboembolic pulmonary hypertension; COMPUTED-TOMOGRAPHY; LUNG PERFUSION; ARTERY OBSTRUCTION; HELICAL CT; ROW CT; EMBOLISM; THROMBOENDARTERECTOMY; ABNORMALITIES; GUIDELINES; DISEASE;
D O I
10.1007/s00330-013-2975-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Methods Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Results Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (kappa=0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (kappa=0.31) to slight (kappa=0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Conclusions Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. Key Points Chronic thromboembolic pulmonary hypertension (CTEPH) is potentially treatable by surgery. Dual-energy computed tomography (DECT) allows angiography and perfusion using a single acquisition. Both DECT perfusion and angiography showed satisfactory diagnostic performance in CTEPH. DECT perfusion was more accurate than angiography in identifying segmental abnormalities.
引用
收藏
页码:42 / 51
页数:10
相关论文
共 50 条
  • [21] Effectiveness of Dual-Energy Computed Tomography in Providing Information on Pulmonary Perfusion and Vessel Morphology in Chronic Thromboembolic Pulmonary Hypertension
    Shimokawahara, Hiroto
    Ijuin, Shun
    Nuruki, Norihito
    Sonoda, Masahiro
    [J]. CIRCULATION JOURNAL, 2015, 79 (11) : 2517 - 2519
  • [22] Diagnostic accuracy of lung subtraction iodine mapping CT for the evaluation of pulmonary perfusion in patients with chronic thromboembolic pulmonary hypertension: Correlation with perfusion SPECT/CT
    Tamura, Masashi
    Yamada, Yoshitake
    Kawakami, Takashi
    Kataoka, Masaharu
    Iwabuchi, Yu
    Sugiura, Hiroaki
    Hashimoto, Masahiro
    Nakahara, Tadaki
    Okuda, Shigeo
    Nakatsuka, Seishi
    Sano, Fumiya
    Abe, Takayuki
    Maekawa, Yuichiro
    Fukuda, Keiichi
    Jinzaki, Masahiro
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 243 : 538 - 543
  • [23] Identification of pulmonary embolism: diagnostic accuracy of venous-phase dual-energy CT in comparison to pulmonary arteries CT angiography
    Foti, Giovanni
    Silva, Ronaldo
    Faccioli, Niccolo
    Fighera, Alessandro
    Menghini, Rossella
    Campagnola, Arianna
    Carbognin, Giovanni
    [J]. EUROPEAN RADIOLOGY, 2021, 31 (04) : 1923 - 1931
  • [24] Identification of pulmonary embolism: diagnostic accuracy of venous-phase dual-energy CT in comparison to pulmonary arteries CT angiography
    Giovanni Foti
    Ronaldo Silva
    Niccolò Faccioli
    Alessandro Fighera
    Rossella Menghini
    Arianna Campagnola
    Giovanni Carbognin
    [J]. European Radiology, 2021, 31 : 1923 - 1931
  • [25] Dual-energy CT angiography of chronic thromboembolic disease: Can it help recognize links between the severity of pulmonary arterial obstruction and perfusion defects?
    Renard, Benoit
    Remy-Jardin, Martine
    Santangelo, Teresa
    Faivre, Jean-Baptiste
    Tacelli, Nunzia
    Remy, Jacques
    Duhamel, Alain
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (03) : 467 - 472
  • [26] Diagnostic accuracy of coronary CT angiography combined with dual-energy myocardial perfusion imaging for detection of myocardial infarction
    Han, Ruijuan
    Sun, Kai
    Lu, Bin
    Zhao, Ruiping
    Li, Kuncheng
    Yang, Xinchun
    [J]. EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (01) : 207 - 213
  • [27] Evaluation of diagnostic accuracy of dual-energy computed tomography in patients with chronic thromboembolic pulmonary hypertension compared to V/Q-SPECT and pulmonary angiogram
    Schuessler, Armin
    Lug, Quirin
    Kremer, Nils
    Harth, Sebastian
    Kriechbaum, Steffen D.
    Richter, Manuel J.
    Guth, Stefan
    Wiedenroth, Christoph B.
    Tello, Khodr
    Steiner, Dagmar
    Seeger, Werner
    Krombach, Gabriele Anja
    Roller, Fritz Christian
    [J]. FRONTIERS IN MEDICINE, 2023, 10
  • [28] ACCURACY OF CONTRAST ENHANCED MR LUNG PERFUSION COMPARED TO PERFUSION SCINTIGRAPHY IN DIAGNOSING CHRONIC THROMBOEMBOLIC PULMONARY HYPERTENSION
    Rajaram, S.
    Swift, A. J.
    Capener, D.
    Hill, C.
    Davies, C.
    Elliot, R.
    Hurdman, J.
    Condliffe, R.
    Wild, J. M.
    Kiely, D. G.
    [J]. THORAX, 2011, 66 : A13 - A14
  • [29] Microvasculopathy evaluated by dual-energy computed tomography in chronic thromboembolic pulmonary hypertension and pulmonary arterial hypertension
    Miwa, K.
    Taniguchi, Y.
    Sumimoto, K.
    Matsuoka, Y.
    Izawa, Y.
    Onishi, H.
    Tsuboi, Y.
    Toba, T.
    Kobayashi, S.
    Emoto, N.
    Hirata, K.
    [J]. EUROPEAN HEART JOURNAL, 2020, 41 : 2254 - 2254
  • [30] Accuracy of helical CT compared with MR imaging and angiography in chronic thromboembolic pulmonary hypertension
    Sirlin, CB
    Bergin, CJ
    Huynh, TV
    Hauschildt, JP
    Auger, WR
    Fedullo, PF
    [J]. RADIOLOGY, 1996, 201 : 945 - 945