Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

被引:118
|
作者
Dournes, Gael [1 ,2 ]
Verdier, Damien [1 ,2 ]
Montaudon, Michel [1 ,2 ]
Bullier, Eric [3 ]
Riviere, Annalisa [3 ]
Dromer, Claire [4 ]
Picard, Francois [5 ]
Billes, Marc-Alain [6 ]
Corneloup, Olivier [1 ]
Laurent, Francois [1 ,2 ]
Lederlin, Mathieu [1 ,2 ]
机构
[1] Hop Haut Leveque, Dept Med Imaging, CHU Bordeaux, F-33600 Pessac, France
[2] Univ Bordeaux Segalen, F-33076 Bordeaux, France
[3] Hop Haut Leveque, CHU Bordeaux, Dept Nucl Med, F-33600 Pessac, France
[4] Hop Haut Leveque, CHU Bordeaux, Dept Resp Dis, F-33600 Pessac, France
[5] Hop Haut Leveque, CHU Bordeaux, Dept Cardiol, F-33600 Pessac, France
[6] Hop Haut Leveque, CHU Bordeaux, Dept Cardiac Surg, F-33600 Pessac, France
关键词
Dual energy CT; Dual energy lung perfusion imaging; Pulmonary scintigraphy; Pulmonary hypertension; Chronic thromboembolic pulmonary hypertension; COMPUTED-TOMOGRAPHY; LUNG PERFUSION; ARTERY OBSTRUCTION; HELICAL CT; ROW CT; EMBOLISM; THROMBOENDARTERECTOMY; ABNORMALITIES; GUIDELINES; DISEASE;
D O I
10.1007/s00330-013-2975-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Methods Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Results Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (kappa=0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (kappa=0.31) to slight (kappa=0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Conclusions Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. Key Points Chronic thromboembolic pulmonary hypertension (CTEPH) is potentially treatable by surgery. Dual-energy computed tomography (DECT) allows angiography and perfusion using a single acquisition. Both DECT perfusion and angiography showed satisfactory diagnostic performance in CTEPH. DECT perfusion was more accurate than angiography in identifying segmental abnormalities.
引用
收藏
页码:42 / 51
页数:10
相关论文
共 50 条
  • [1] Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy
    Gaël Dournes
    Damien Verdier
    Michel Montaudon
    Eric Bullier
    Annalisa Rivière
    Claire Dromer
    François Picard
    Marc-Alain Billes
    Olivier Corneloup
    François Laurent
    Mathieu Lederlin
    [J]. European Radiology, 2014, 24 : 42 - 51
  • [2] Dual-energy CT (DECT) lung perfusion in pulmonary hypertension: concordance rate with V/Q scintigraphy in diagnosing chronic thromboembolic pulmonary hypertension (CTEPH)
    Masy, Matthieu
    Giordano, Jessica
    Petyt, Gregory
    Hossein-Foucher, Claude
    Duhamel, Alain
    Kyheng, Maeva
    De Groote, Pascal
    Fertin, Marie
    Lamblin, Nicolas
    Bervar, Jean-Francois
    Remy, Jacques
    Remy-Jardin, Martine
    [J]. EUROPEAN RADIOLOGY, 2018, 28 (12) : 5100 - 5110
  • [3] Dual-energy CT (DECT) lung perfusion in pulmonary hypertension: concordance rate with V/Q scintigraphy in diagnosing chronic thromboembolic pulmonary hypertension (CTEPH)
    Matthieu Masy
    Jessica Giordano
    Grégory Petyt
    Claude Hossein-Foucher
    Alain Duhamel
    Maeva Kyheng
    Pascal De Groote
    Marie Fertin
    Nicolas Lamblin
    Jean-François Bervar
    Jacques Remy
    Martine Remy-Jardin
    [J]. European Radiology, 2018, 28 : 5100 - 5110
  • [4] Dual-Energy CT Angiography for Assessment of Regional Pulmonary Perfusion in Patients With Chronic Thromboembolic Pulmonary Hypertension: Initial Experience
    Hoey, Edward T. D.
    Mirsadraee, Saeed
    Pepke-Zaba, Joanna
    Jenkins, David P.
    Gopalan, Deepa
    Screaton, Nicholas J.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (03) : 524 - 532
  • [5] Dual-Energy CT Pulmonary Angiography for the Assessment of Surgical Accessibility in Patients with Chronic Thromboembolic Pulmonary Hypertension
    Eberhard, Matthias
    McInnis, Micheal
    de Perrot, Marc
    Lichtblau, Mona
    Ulrich, Silvia
    Inci, Ilhan
    Opitz, Isabelle
    Frauenfelder, Thomas
    [J]. DIAGNOSTICS, 2022, 12 (02)
  • [6] Pilot study comparing SPECT perfusion scintigraphy with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension
    Soler, Xavier
    Kerr, Kim M.
    Marsh, James J.
    Renner, John W.
    Hoh, Carl K.
    Test, Victor J.
    Morris, Timothy A.
    [J]. RESPIROLOGY, 2012, 17 (01) : 180 - 184
  • [7] Lung Dual-Energy CT Perfusion Blood Volume as a Marker of Severity in Chronic Thromboembolic Pulmonary Hypertension
    Si-Mohamed, Salim A.
    Zumbihl, Lea
    Turquier, Segolene
    Boccalini, Sara
    Mornex, Jean-Francois
    Douek, Philippe
    Cottin, Vincent
    Boussel, Loic
    [J]. DIAGNOSTICS, 2023, 13 (04)
  • [8] Use of dual-energy CT-scan compared to V/Q-scintigraphy in the diagnostic workout of chronic thromboembolic pulmonary hypertension
    Claus, E.
    Van Meerbeeck, S.
    Lambert, B.
    Devos, D.
    De Pauw, M.
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 : 626 - 626
  • [9] Dual energy CT pulmonary angiography: findings in a patient with chronic thromboembolic pulmonary hypertension
    Hoey, E. T. D.
    Agrawal, S. K. B.
    Ganesh, V.
    Gopalan, D.
    Screaton, N. J.
    [J]. THORAX, 2009, 64 (11) : 1012 - 1012
  • [10] Dual-energy CT was effective to evaluate of microvasculopathy in chronic thromboembolic pulmonary hypertension
    Onishi, H.
    Taniguchi, Y.
    Matsuoka, Y.
    Yanaka, K.
    Izawa, Y.
    Mori, S.
    Otake, H.
    Satomi-Kobayashi, S.
    Emoto, N.
    Hirata, K.
    [J]. EUROPEAN HEART JOURNAL, 2019, 40 : 3082 - 3082