摘要
Signal Targeting with Alternating Radiofrequency (STAR) and STAR and Flow-independent Relaxation Enhancement (STARFIRE) are noncontrast methods for flow-dependent and flow-independent magnetic resonance angiography (MRA). The methods rely on the acquisition and complex subtraction of two image sets alternately labeled by spatially selective or spatially nonselective inversion radio frequency (RF) pulses. Experimental results show that the RF labeling period affects the extent of the carotid vessels seen with STAR imaging, and the conspicuity of cerebrospinal fluid (CSF) and fat in the STARFIRE images. Both methods were found to provide more detailed depiction of the carotid arteries than the alternative noncontrast MRA technique of time-of-flight (TOF) angiography. Magn Reson Med 61:117-124, 2009. (C) 2008 Wiley-Liss, Inc.
引用
收藏
页码:117 / 124
页数:8
相关论文
共 50 条
  • [1] Flow-dependent versus flow-independent initial perturbations for ensemble prediction
    Magnusson, Linus
    Nycander, Jonas
    Kallen, Erland
    [J]. TELLUS SERIES A-DYNAMIC METEOROLOGY AND OCEANOGRAPHY, 2009, 61 (02) : 194 - 209
  • [2] Magnetization-Prepared IDEAL bSSFP: A Flow-Independent Technique for Noncontrast-Enhanced Peripheral Angiography
    Cukur, Tolga
    Shimakawa, Ann
    Yu, Huanzhou
    Hargreaves, Brian A.
    Hu, Bob S.
    Nishimura, Dwight G.
    Brittain, Jean H.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (04) : 931 - 939
  • [3] FLOW-INDEPENDENT MAGNETIC-RESONANCE PROJECTION ANGIOGRAPHY
    WRIGHT, GA
    NISHIMURA, DG
    MACOVSKI, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (01) : 126 - 140
  • [4] Three-dimensional flow-independent peripheral angiography
    Brittain, JH
    Olcott, EW
    Gold, GE
    Szuba, A
    Wright, GA
    Nishimura, DG
    [J]. RADIOLOGY, 1996, 201 : 359 - 359
  • [5] Three-dimensional flow-independent peripheral angiography
    Brittain, JH
    Olcott, EW
    Szuba, A
    Gold, GE
    Wright, GA
    Irarrazaval, P
    Nishimura, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) : 343 - 354
  • [6] Flow-independent angiography for peripheral vascular disease: Initial in-vivo results
    Gronas, R
    Kalman, PG
    Kucey, DS
    Wright, GA
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (04): : 637 - 643
  • [7] Unenhanced Flow-Independent MR Venography by Using Signal Targeting Alternative Radiofrequency and Flow-Independent Relaxation Enhancement
    Edelman, Robert R.
    Koktzoglou, Ioannis
    [J]. RADIOLOGY, 2009, 250 (01) : 236 - 245
  • [8] Actin flow-dependent and -independent force transmission through integrins
    Driscoll, Tristan P.
    Ahn, Sang Joon
    Huang, Billy
    Kumar, Abhishek
    Schwartz, Martin A.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2020, 117 (51) : 32413 - 32422
  • [9] Nonenhanced magnetic resonance angiography (MRA) of the calf arteries at 3 Tesla: intraindividual comparison of 3D flow-dependent subtractive MRA and 2D flow-independent non-subtractive MRA
    Gesine Knobloch
    Marie-Teres Lauff
    Sebastian Hirsch
    Carsten Schwenke
    Bernd Hamm
    Moritz Wagner
    [J]. European Radiology, 2016, 26 : 4585 - 4594
  • [10] Nonenhanced magnetic resonance angiography (MRA) of the calf arteries at 3 Tesla: intraindividual comparison of 3D flow-dependent subtractive MRA and 2D flow-independent non-subtractive MRA
    Knobloch, Gesine
    Lauff, Marie-Teres
    Hirsch, Sebastian
    Schwenke, Carsten
    Hamm, Bernd
    Wagner, Moritz
    [J]. EUROPEAN RADIOLOGY, 2016, 26 (12) : 4585 - 4594